• Petroleum Coke

 Never burn petroleum coke as this 

burns at a very high temperature and its continued 
use will almost certainly cause irreparable damage to 
components such as the grate, baffle plate and fire- 
fence.

• Bituminous House Coal

 is not recommended  

because it produces excessive soot deposits, which is 
not good for the environment, and thus considerably 
increases the need for frequent cleaning of the stove 
and flue system.

• Household Rubbish

 Printed matter (excluding very 

small amounts of newspaper for starting the fire),  
plastic, rubber, lacquered or impregnated wood,  
plywood, chipboard and household rubbish, such as 
milk cartons, should also be avoided. During  
combustion some of these materials may develop 
substances which could be hazardous to your health 
and be harmful to the environment. 

• Flammable Liquids

 Never use methylated spirits, 

petrol or other highly inflammable liquids for  
lighting the fire as these could cause an explosion  
in the confined spaces of the fire chamber. 
 

UNDERSTANDING HOW 

DIFFERENT FUELS BURN

Wood and solid or mineral fuels (multi fuels) burn in 
different ways and you will need to understand these  
differences if you are a newcomer to wood burners 
and multi fuel stoves. 
Putting it simply, mineral fuels, such as coal or  
smokeless ovals, need a flow of combustion air 
through the bottom grate which is known as Primary 
Air, whereas wood fuel works much better when its 
combustion air is taken from above the grate. This 
source of air is known as Secondary Air. Wood always 
burns best on a bed of its own embers and the ashes 
shouldn’t need to be riddled. Again mineral fuels  
differ because they need combustion air from below 
the grate and therefore the grate needs to be  
regularly riddled to keep the air passage clear.
See the section below to help you understand how 
to control the different types of combustion air that 
wood and mineral fuels need.
Your new stove can burn very well, or very poorly, 
depending on how you light the fire, how you refuel 
the fire, and, of course, the type and quality of the 
fuel that you are burning. A log moisture meter is a 
cost-effective investment if you want to maximise the 
efficiency of your stove and wood fuel.
Wear protective gloves when loading a burning stove 
and place the fuel precisely where you want it in the 
fire chamber by using heat-resistant tongs. Always 
open the stove door gently to avoid unnecessary air 
turbulence which could cause fly ash or small lighted 
embers to be drawn from the fire chamber and  
beyond the protective hearth. 

14

The stove is 

not

 designed to be operated with the 

door left open continuously – this will reduce its  
operating efficiency and it will consume more fuel 
very quickly and produce less heat.

 

 

CONTROLLING THE COMBUSTION AIR

Your Graphite Boiler stove has three simple-to-use air 
controls: 

1 Primary Air Control

 This is the large control knob 

in the centre at the base of the stove front. Primary 
Air is required when burning mineral fuels (and to 
quickly aid the supply of air during the initial  
combustion of wood). Using the tool provided, turn it 
anti-clockwise to open and add combustion air.

2 Secondary Air Control

 This is the sprung slider 

control in the middle of the grille above the door. 
Move it to the right for the maximum supply of air 
and to the left to limit this supply. Secondary Air 
is needed when burning wood and is not usually 
needed when burning mineral fuels (unless it is to 
maximise the air supply to aid the initial combustion). 

3 Thermostat Control

 Zero is closed and 8 fully 

open. This adjusts the temperature of the water 
leaving the boiler from low when closed off (approx 
50ºC) to high (approx 90ºC) by controlling part of the 
combustion air supply to the fire chamber.
The effectiveness of adjustment will involve the  
interaction of the Primary and Secondary Air supply 

The Primary Air Control

The Secondary Air Control

Содержание GR910-B

Страница 1: ... to make a claim under the Hi Flame Warranty You will find the serial number beginning with GR on the CE plate at the rear of the stove as well as on the lid of the outer packaging Write the date the stove was delivered to you below as this is likely to differ from the purchase date Remember to keep your receipt as proof of purchase Ref GR910 B UK NI ROI V3 06 15 www hi flame com Graphite This appli...

Страница 2: ...for guidance purposes only may differ slightly from your new Hi Flame Graphite Boiler stove However the principles illustrated here remain the same Hi Flame Fireplace UK Limited CONTENTS Page 4 5 5 5 6 6 7 7 7 8 8 8 9 10 11 12 13 13 14 14 15 15 17 17 17 18 19 19 20 22 22 General Dimensions General Specifications including minimum distances Permanent Air Supply Standard Features and Controls Packing...

Страница 3: ...alling this stove in a UK Smoke Control Area the Hi Flame Graphite Boiler stove can only be fuelled with approved smokeless fuels it will be illegal to burn wood or any other non approved fuels in it Even if you have installed or operated stoves before remember manufacturer s requirements can vary and can also change with updates to building regulations therefore please read this manual before you...

Страница 4: ...4 GENERAL DIMENSIONS ...

Страница 5: ...4 8kg approx 10lb 9oz Maximum Log Length 400 mm 16 Or Approved Smokeless Fuels www solidfuel co uk Maximum Mineral Fuel Load 3 8kg approx 8lb 6oz PERMANENT AIR SUPPLY IMPORTANT The total rated output of this stove is 15 1kW Building Regulations permanent ventilation requirements should be based on this total output and not just the stove s output to the room Approved Document J of the Building Reg...

Страница 6: ...In the confined space of the stove s fire chamber there is a real potential to cause a life threatening flash flame or explosion Never over fire the stove If any external parts of your stove glow red during operation then immediate action should be taken to reduce the supply of combustion air to the fire chamber through the Primary Secondary and Thermostatic Air controls which should quickly limit the i...

Страница 7: ... of any residue water during maintenance or removal All electrical connections for example to system valves the circulating pump and the link up component must comply with current Building Regulations Ensure that the pipework is correctly earthed See page 8 and 24 for relevant regulations The mains water connection to the system must 7 comply with local water authority regulations in order to safe...

Страница 8: ...lid fuel and wood burning appliances and systems are subject to the requirements of Building Regulations These regulations must be observed and such installations need to be notified to the relevant Local Authority Building Control department by law Hetas www hetas co uk is the official body recognised by the Government to approve solid fuel domestic heating appliances and the registration of compet...

Страница 9: ... packaging You must retain this until the stove is installed and is fully operational Remember to keep the bar coded serial number label Unfasten retaining wires and remove any components including those inside the ash pan from inside the stove Inspect Check the stove has not been damaged in transit never attempt to install a stove which has been damaged If damage is suspected then report this imm...

Страница 10: ...ou ll see the baffle plate lug Push the baffle upwards to one side so that you can drop the plate down and move it out of the way to clear the lower retaining ledge Should there be excessive soot debris then you will need to review how you operate your stove and also check the quality of your fuel The Graphite Boiler s wide body means that you should not rely solely on being able to clear exces sive...

Страница 11: ...e three access panel bolts with the correct sized socket or ring spanner and loosen and remove any fire cement seal Gently and evenly prise around the plate to free it from its cement seal Do not attempt to lever the plate from one point only as this could put undue pressure where the plate still secured causing it to crack Clean the boiler and flueway using a lightweight wire brush if necessary Che...

Страница 12: ...sant smoky smells both inside and sometimes outside the house In the event of a problem with your stove always check your choice of fuel first Manufactured or finished wood products such as plywood and chipboard must also be strictly avoided because of the high chemical adhesive content used in their production which will also leave harmful potentially corrosive residue inside the stove and flue syst...

Страница 13: ...pes of combustion air that wood and mineral fuels need Your new stove can burn very well or very poorly depending on how you light the fire how you refuel the fire and of course the type and quality of the fuel that you are burning A log moisture meter is a cost effective investment if you want to maximise the efficiency of your stove and wood fuel Wear protective gloves when loading a burning stove ...

Страница 14: ... and gases whenever possible point the log ends away from the glass to help keep the glass clean Fuel Load Ideally the logs should be approximately 400mm 16 long A typical fuel load should weigh approximately 4 8kg 10lb 9oz To get the best out of your stove ideally you will need three different thicknesses of wood log as you build the fire through each lighting phase 1 Kindling This is generally fin...

Страница 15: ...rds the glass as this is where some of the gases and moisture from the logs escapes and this can cause staining which the Airwash may find difficult to remove Only reduce the Secondary Air control when the wood has carbonised and the fire is burning at a high temperature This is when the ash on the burning wood looks light grey and virtually covers all of the wood You will be able to tell when the st...

Страница 16: ...commend burning your Graphite Boiler on high output for at least 30 minutes each day to help burn off any potential soot or creosote build up but be careful not to over fire the stove 2 Small regular loads when refuelling will produce a more efficient and cleaner burning performance 3 Avoid burning large amounts of wood with the Secondary Air supply turned down as this will reduce the effectiveness ...

Страница 17: ...rature and the burn rate of the mineral fuel load and therefore the heat into the room To do this ensure the Primary and Secondary Air is fully closed Then simply control the flame pattern and burn rate with the Thermostat Control However you may still need to undertake some subtle adjustments to both the Primary and Secondary Air supply to achieve the correct balance of combustion air for your sto...

Страница 18: ... requirement of your Warranty that the stove is installed by a competent person such as a Hetas or INFO registered installer who will be fully aware of any building and safety regulations which apply to stove installations in your location Boiler Stove Location Checklist The existing constructional hearth the main part of the hearth is suitably constructed and is of a thickness that conforms to al...

Страница 19: ...east 125mm 5 thick This can include the thickness of any non combustible floor under the hearth or non combustible decorative surface It must be capable of supporting the weight of the stove when loaded and boiler with water add approx 15kg along with any attached flexible flue liner which may bear down on the stove This hearth must conform to local building regulations which may vary from country to...

Страница 20: ...e the stove s operation with greater control over the fuel burn rate and efficiency Your existing chimney could leak smoke fumes and potentially dangerous invisible carbon monoxide into other parts of the building Condensation or creosote tar often associated with burning wood could eventually seep through the walls particularly if they are made of old or porous brick and or are jointed with lime m...

Страница 21: ... diagram shown overleaf should be used for general guidance purposes only and is included here to demonstrate basic system principles Combined with the at a glance list below this should provide you with a basic understanding of the essential requirements your system should have As each system and its requirements will vary the list below is by no means meant to be comprehensive A good system shou...

Страница 22: ... 23 ...

Страница 23: ...s not overheat A low limit thermostat set at 45ºC should be fitted to the gravity return pipework and connected to the circulating pump This should be set to come on when the water temperature reaches above 45ºC to begin the circulation process Hot water cylinder The water system must be properly vented and you must use a double feed indirect cylinder which is in accordance with current issue of BS...

Страница 24: ...rements Explain the householder s legal requirement to use an approved fireguard whenever children or the elderly and the infirm are likely to be in the vicinity of the stove If the installation is in a designated Smoke Control Area then also explain the householder s responsibility only to use approved smokeless fuels 8 Instruction Manual Make sure that the customer receives this copy of the Instru...

Страница 25: ...ow it is extremely important that the radiators are balanced to ensure an efficient distribution of heat as well as an even heat balance from one radiator to the next The idea is to reduce the flow to the hottest radiators so that more hot flow is available to heat the coolest ones The system is balanced when there is a good hot water flow through every central heating radiator To undertake this all o...

Страница 26: ...could also indicate that the chimney or flue itself also needs cleaning Causes Inadequate supply of combustion air Check that any permanent air vent fitted to supply the extra combustion air required for the stove has not been accidentally blocked Remember there should never be an extractor fan in the same room as a stove A simple way of checking whether or not the stove is receiving enough combusti...

Страница 27: ...lem because the Airwash does not get hot enough and some blackening of the glass should be considered a because draught stabilisers limit the exit of flue gases from the stove they should only ever be specified fitted and subsequently tested by an approved installer Causes Fuel The fuel itself may be of poor quality For example pine and other softwoods used in the building trade will burn much quicke...

Страница 28: ...ter then it is more than likely to be a problem with the system The simplest way to determine this is if possible to check that the top water pipe from the stove is hot and that the lower pipe is cooler If this is the case then this indicates that there is a problem with the system and not the stove Causes Circulation pump or thermostatic valve failure A fault in one of the system s key components...

Страница 29: ...move the log retaining bar by lifting it upwards to expose the bolt head at the top of the firebrick retaining clamp Always use penetrating oil to help release the bolt and use the correct sized spanner or socket Do not force the bolt Then simply remove the damaged bricks and replace them both with new ones When replacing and clamping the bricks in place ensure they make good contact with the insid...

Страница 30: ...es as this type of polish can cause deep staining to the skin and fingernails Repair worn or scratched surfaces with a proprietary heat resistant spray paint made specially for stoves also available from your stove dealer Never use an aerosol spray on or near the stove when it is burning or it is hot Door Rope Seals It is important that you maintain a tight door seal as this prevents unwanted air l...

Страница 31: ...onal performance and safety standards It is not the responsibility of Hi Flame or their distributors to ensure that the appliance is installed and operating correctly at the time of the installation This is strictly the responsibility of the stove owner and any complaints regarding the performance of the installation should be addressed to the stove dealer or the stove installer HI Flame offers th...

Страница 32: ... Hi Flame technical department pressure tests then under the terms of Hi Flame s 1 year or extended 5 year warranty your reasonable expenses provided receipts are provided to us will reimbursed and an appropriate replacement supplied subject to model availability What the Hi Flame Warranty DOES NOT cover In line with other manufacturers the Warranty does NOT cover the following consumable items Fi...

Страница 33: ...k all parts for wear or damage and replace as necessary Re fit internal parts and flueway access lid Stove Glass Check the glass for chips or cracks and the glass seal condition and replace if necessary Thoroughly clean the stove glass on both sides Door Seal Check that this makes an air tight seal and replace if necessary Ensure that the new rope joint is also in the middle at the base of the rope ...

Страница 34: ... AND SETTINGS For future reference include a basic drawing of the system and notes on the circulation pump and system thermostat settings etc as well as their location and the location of the system drain point 35 ...

Страница 35: ...mes Chapel Cheshire CW4 8AF United Kingdom Hi Flame Fireplace UK Limited 2014 All rights reserved Booklet contents may not be copied in whole or in part without the prior written permission of the copyright holder Hi Flame and Graphite are the company name and trading names of Hi Flame Fireplace UK Limited Graphite ...

Отзывы: