background image

Enter “     <User ID Number>#”

*

To Change a User Code

Enter <old User Code> #

RED LED goes YELLOW

YELLOW LED goes 

GREEN for 1/2 sec if OK or 

beep beep beep if not OK

RED flashing LED goes green 

for 1/2 sec. then RED no flash

Enter “<new User Code>#”

(4 digits)

Enter “<new User Code>#”

 (4 digits) to confirm

press “ # ” then “   ” to exit 

programming mode

*

Record Master Code Here:

Programming Instructions for MAW6 Digital Keypad

To Change the Master Code

Record User ID numbers and Codes Here:

Enter “   <Master Code># ”

Factory code “ 999-999 ”

*

RED flashing LED goes green 

for 1/2 sec. then RED no flash

press “ 0 ”

RED LED goes YELLOW

YELLOW LED goes 

GREEN for 1/2 sec if OK or 

beep beep beep if not OK

Enter “<new Master Code>#”

(6 to 8 digits)

Enter “<new Master Code>#”

 (6 to 8 digits) to confirm

press “ # ” then “   ” to exit 

programming mode

*

User Name and/or Description

User ID Number

User Code

Restoring Factory Settings.

The factory settings can be recov-

ered it necessary without loosing 

any user codes, tags or cards pro-

grammed in.  To do this remove 

power from the device, then after 

15 seconds press and hold the “#’ 

key and restore power.  When the 

decive beeps left go of the “#” key 

as the factory settings have been 

restored. 

www.grantsautomation.com.au - [email protected]

Содержание MAW6

Страница 1: ...Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card F reader www grantsautomation com au grant grantsautomation com au ...

Страница 2: ...s Ideal as a way for pedestrians to exit without a code Door In is for a mag netic reed or micro switch fitted to a gate to activate an alarm if not closed in 1 minute after use For Pedestrian Gates fitted with an electric Strike Lock or magnetic Lock Electric Strike Lock 12VDC Magnetic Lock 12VDC Maw 6 Digital Keypad Touch Tag Reader Buzz A Pink Buzz B Pale Blue WG DO Green WG D1 White Alarm Grey...

Страница 3: ...ss Control Alarms system Wiring Diagrams for MAW6 Digital Keypad Maw 6 Digital Keypad Touch Tag Reader Buzz A Pink Buzz B Pale Blue WG DO Green WG D1 White Alarm Grey Exit P B Yellow Door In Brown 9 to 28VDC Red Ground Black NO Blue COM Purple NC Orange For 24V Automatic Gate Operator or 240V operator with 24VAC or DC output for accessories Automatic Gate Operator Control Board P B in 24V out Grou...

Страница 4: ...Code or Tag Card by ID Do you want to Add more No Yes Do you want to remove more No Yes www grantsautomation com au grant grantsautomation com au Enter User Code 4 digits or Swipe Tag Card LED will go GREEN for 1 2 sec if Code or Card OK or beep beep beep if not OK press then to exit programming mode press 2 RED LED goes YELLOW Enter User ID Number 1 to 2000 LED will go GREEN for 1 2 sec if OK or ...

Страница 5: ... Code Factory code 999 999 RED flashing LED goes green for 1 2 sec then RED no flash LED will go GREEN for 1 2 sec if OK or beep beep beep if not OK Set Tag Card Code Option press 31 press then to exit programming mode Enter Master Code Factory code 999 999 RED flashing LED goes green for 1 2 sec then RED no flash LED will go GREEN for 1 2 sec if OK or beep beep beep if not OK Set Tag Card OR Code...

Страница 6: ...ing LED goes green for 1 2 sec then RED no flash press 0 RED LED goes YELLOW YELLOW LED goes GREEN for 1 2 sec if OK or beep beep beep if not OK Enter new Master Code 6 to 8 digits Enter new Master Code 6 to 8 digits to confirm press then to exit programming mode User Name and or Description User ID Number User Code Restoring Factory Settings The factory settings can be recov ered it necessary wit...