Specifi cations

Case Dimensions:

6

¹⁄₂

”L x 1

³⁄₄

”W x 1

¹⁄₈

”D

Electrical: 

Voltage: 12-24VAC/DC

Current: 53mA@12VDC; 
72mA@24VDC; 95mA@12VAC
108mA@24VAC

Relay Contacts:

Main Relay (controller): 2A 

Bell Relay:
Form A; 1 Amp @ 30VAC/DC

Environmental:

-20° F to 130° F
For Indoor and Outdoor Use

Features

•  120 User Capacity
•  Programmable Relay Time (0 to 99 seconds)
•  Request to Exit (REX) Input
•  Vandal Resistant Case
•  Sealed for Indoor or Outdoor Applications
•  LED’s for Relay Status Indication
• Bell Output
• Surface Mount
•  Illuminated Hardened Keys
•  Rated for Greater than One Million Key Cycles

Applications

•  Low to Medium/Heavy Traffi c Areas
•  Rough Service Environments
•  Mullion Frame Mounting
•  Dimly Lit Areas

Description:

Schlage’s KP212 keypad combines elegant looks with a mullion 
mount design in a rugged, vandal resistant case, which you can use 
for almost any application. The KP212 has hardened backlit keys 
designed to perform in medium to high traffi c areas and in rough 
duty environments. The electronics are also conformal coated, which 
makes the keypad suitable for indoor or outdoor applications.

Basic Operation:

To gain access through the door enter your code (1-6 digits) followed 
by the 

 key on the keypad.

Packing List:

1) KP212 Keypad

(1) Eight-Conductor Wire Harness

(1) Mullion Hardware Pack

(1) 

⁵⁄₆₄

” Allen Wrench

(1) Anti-Oxidant Grease Pack

(1) Installation/Programming Manual

Wire Harness Confi guration:

2
4
6
8




7

Pin

Wire Color

Signal Name

1

Red

Power (+)

2

Black

Power (-)

3

White/Black

REX

4

White/Yellow

Main Relay NC

5

Blue

Main Relay Common

6

Brown

Main Relay NO

7

White

Bell Relay Contact (A)

8

White

Bell Relay Contact (B)

Содержание KP212

Страница 1: ...ounting Dimly Lit Areas Description Schlage s KP212 keypad combines elegant looks with a mullion mount design in a rugged vandal resistant case which you can use for almost any application The KP212 has hardened backlit keys designed to perform in medium to high traffic areas and in rough duty environments The electronics are also conformal coated which makes the keypad suitable for indoor or outd...

Страница 2: ...pad onto the mounting surface using the provided screws Do no over tighten the screws which may result in damage Keypad Mounting Height Mounting height can vary depending on requirements An appropriate range is typically between 48 and 52 inches on center off the floor 48 52 Wiring an Electromagnetic Lock Maglock 1 Connect the red V and black V wires to your power supply 2 Connect the blue wire re...

Страница 3: ...mally open to the positive connection on your door strike 4 Connect negative connection on your door strike to the negative on the power supply Shunting a Normally Closed Zone 1 Connect the red V and black V wires to your power supply 2 Connect the blue wire relay common to the common connection on the alarm contacts 3 Connect the brown wire relay normally open to the normally open connection on t...

Страница 4: ...the negative on your power supply 3 Connect the white black wire to the normally open connection on the REX device Wiring the Bell Output to a Speaker The KP212 keypad has a built in bell button which triggers a relay output when pressed This relay is normally open and the contact closes when triggered You can use this relay output to trigger devices that require a momentary closure such as a door...

Страница 5: ...ode Command 30 Set Clear Keypad Options options below defaults in bold 30 option set clear Option Clear Set 0 Audio Keypress Feedback 0 Disabled 1 Enabled 1 Visual Keypress Feedback 0 Disabled 1 Enabled 2 Auto Entry 0 Disabled 1 Enabled 3 Keypad Illumination 0 Disabled 1 Enabled 4 Keypad Dimming 0 Disabled always bright 1 Enabled 5 Door Bell Select 0 Disabled 1 Enabled Command 32 Set Bell Output T...

Страница 6: ...e following example shows how to program user 2 with a code of 1749 and user 3 with 9328 The master code is 4875 1 Enter Program Mode 99 4875 2 Program User 2 2 1749 code 3 Program User 3 3 9328 code 4 Exit Program Mode Programming a Toggle User The following example shows how to program user 4 as a toggle user with a code of 98773 The master code is 4875 1 Enter Program Mode 99 4875 2 Change the ...

Страница 7: ...support department at 1 800 343 9502 outside MA or 1 800 733 9502 inside MA Testing the Keypad After installing the keypad IEI recommends that you perform the keypad self test once a year to ensure that the keypad is working properly To perform the self test with the unit powered up press the following keys on the keypad 7890 123456 If all 12 key presses are accepted the keypad enters self test mo...

Страница 8: ...0 Rev 04 11 a Keypad Mounting Template Mounting Holes Wiring Hole 3 3 393 1 1 433 The Schlage keypad is desingd for surface mount applications You must drill a hole for the wire harness connector as shown so the unit is flat against the mounting surface ...

Отзывы: