Wiring Diagrams for MAW6 Digital Keypad

Maw-6 Digital Keypad/T

ouch 

Tag Reader

Buzz-A - Pink

Buzz-B - Pale 

Blue

WG DO - Green

WG D1 - White

Alarm - Grey

Exit P/B - Yellow

Door In - Brown

9 to 28VDC+ - Red

Ground - Black

NO - Blue

COM - Purple

NC - Orange

12VDC Power Supply

Can be unregulated with an output 

between 9V and 28VDC

+

-

Exit

Exit Button will activate 

the Devices output timer 

in the same manner 

that entering a correct 

code or touching a 

programmed tag or card 

does.  Ideal as a way 

for pedestrians to exit 

without a code.

‘Door In’ is for a mag-

netic reed or micro 

switch fitted to a gate to 

activate an alarm if not 

closed in 1 minute after 

use.

For Pedestrian Gates fitted with an electric 

Strike Lock or magnetic Lock

Electric Strike 

Lock 12VDC

Magnetic 

Lock 12VDC

+

+

-

-

Maw-6 Digital Keypad/T

ouch 

Tag Reader

Buzz-A - Pink

Buzz-B - Pale 

Blue

WG DO - Green

WG D1 - White

Alarm - Grey

Exit P/B - Yellow

Door In - Brown

9 to 28VDC+ - Red

Ground - Black

NO - Blue

COM - Purple

NC - Orange

For 12V Automatic Gate Operator or 240V Operator with 12VDC output for accessories.

Automatic Gate Operator 

Control Board

P/B in

12V+ out

Ground

P/B com

Door

Alarm

-

+

Содержание MAW6

Страница 1: ...Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card F reader www grantsautomation com au grant grantsautomation com au ...

Страница 2: ...s Ideal as a way for pedestrians to exit without a code Door In is for a mag netic reed or micro switch fitted to a gate to activate an alarm if not closed in 1 minute after use For Pedestrian Gates fitted with an electric Strike Lock or magnetic Lock Electric Strike Lock 12VDC Magnetic Lock 12VDC Maw 6 Digital Keypad Touch Tag Reader Buzz A Pink Buzz B Pale Blue WG DO Green WG D1 White Alarm Grey...

Страница 3: ...ss Control Alarms system Wiring Diagrams for MAW6 Digital Keypad Maw 6 Digital Keypad Touch Tag Reader Buzz A Pink Buzz B Pale Blue WG DO Green WG D1 White Alarm Grey Exit P B Yellow Door In Brown 9 to 28VDC Red Ground Black NO Blue COM Purple NC Orange For 24V Automatic Gate Operator or 240V operator with 24VAC or DC output for accessories Automatic Gate Operator Control Board P B in 24V out Grou...

Страница 4: ...Code or Tag Card by ID Do you want to Add more No Yes Do you want to remove more No Yes www grantsautomation com au grant grantsautomation com au Enter User Code 4 digits or Swipe Tag Card LED will go GREEN for 1 2 sec if Code or Card OK or beep beep beep if not OK press then to exit programming mode press 2 RED LED goes YELLOW Enter User ID Number 1 to 2000 LED will go GREEN for 1 2 sec if OK or ...

Страница 5: ... Code Factory code 999 999 RED flashing LED goes green for 1 2 sec then RED no flash LED will go GREEN for 1 2 sec if OK or beep beep beep if not OK Set Tag Card Code Option press 31 press then to exit programming mode Enter Master Code Factory code 999 999 RED flashing LED goes green for 1 2 sec then RED no flash LED will go GREEN for 1 2 sec if OK or beep beep beep if not OK Set Tag Card OR Code...

Страница 6: ...ing LED goes green for 1 2 sec then RED no flash press 0 RED LED goes YELLOW YELLOW LED goes GREEN for 1 2 sec if OK or beep beep beep if not OK Enter new Master Code 6 to 8 digits Enter new Master Code 6 to 8 digits to confirm press then to exit programming mode User Name and or Description User ID Number User Code Restoring Factory Settings The factory settings can be recov ered it necessary wit...

Отзывы: