section 1: introduction
page 5
1.5 instaLLatiOn
Installation must be carried out by a competent installer in
compliance with all current local planning requirements, Building
Regulations, codes of practise, Health and Safety legislation.
1.6 LOCatiOn
The Mag One should be installed on the return leg of the circuit,
between the last radiator and the boiler/heat pump.
table 1-2:
Installation locations
Location
suitable?
Internally
Yes
Inside internal boiler casing
No
Externally
No
Inside external boiler casing
Yes
1.7 ORiEntatiOn
The Mag One body can be rotated by 360° and installed in any
orientation without affecting performance.
1.8 aCCEss anD CLEaRanCEs
Please allow enough clearance around the Mag One to ensure
the isolating valves can be fully closed.
It is recommended that a clearance of at least 250 mm is given to
enable the magnet and filter to be removed during servicing.
Sufficient clearance must also be given to ensure that the Mag
One can be drained easily into a suitable container.
1.9 REDUCinG VaLVEs
The Mag One is supplied with a pair of 28 mm isolating valves
and 28/22 mm reducers for connection to 22 mm pipe.
1.10 MaGnEt CaUtiOnaRy aDViCE
! WaRninG !
The magnet fitted in the Mag One has a strong attractive
force and consideration should be given to the following:
•
Magnets could affect the functioning of pacemakers
and implanted heart defibrillators
•
Keeping magnets away from devices and objects, i.e.
tVs, laptops, credit and atM cards, etc. that could be
damaged by strong magnetic fields.