2.1
CYLINDER TECHNICAL DATA
2.1.1 REGULAR DIAMETER MODELS
Table 2-1:
Cylinder technical data (regular diameter models)
MonoWave Indirect HP Cylinders
Standard efficiency
A rated
125 litre 150 litre 170 litre 200 litre 250 litre 300 litre 400 litre 200 litre
Nominal capacity (litres)
125
150
170
200
250
300
400
200
Actual capacity (litres)
118
136
165
188
222
274
356
202
Overall diameter (mm)
580
580
580
580
580
580
580
580
Overall height (mm)
830
920
1,070
1,192
1,395
1,685
2,085
1,935
Weight - empty (kg)
30
32
45
49
59
68
76
70
Weight - full (kg)
155
182
215
249
309
368
476
270
Secondary return connection (mm)
22
22
22
22
22
22
22
22
Cold feed / hot draw-off connections (mm)
22
22
22
22
22
22
22
22
Primary coil connections (mm)
22
22
22
22
22
22
22
28
Primary coil length (m)
11.68
8.00
8.00
16.00
16.00
16.00
16.00
16.00
Primary coil surface area (m²)
1.5
1.65
1.65
3.3
3.3
3.3
3.3
3.3
Primary coil pipe diameter (mm)
28
32
32
32
32
32
32
32
Maximum water supply pressure (bar)
12
12
12
12
12
12
12
12
System operating pressure - pre-set (bar)
3
3
3
3
3
3
3
3
Expansion vessel charge pressure (bar)
3
3
3
3
3
3
3
3
Expansion relief valve pressure (bar)
6
6
6
6
6
6
6
6
T&P relief valve lift pressure (bar)
7
7
7
7
7
7
7
7
T&P relief valve lift temperature (°C)
90
90
90
90
90
90
90
90
Maximum primary circuit working pressure (bar)
3
3
3
3
3
3
3
3
Performance:
Primary coil rating (kW)
24.0
27.8
27.8
47.0
47.0
56.6
56.6
47.0
Standing heat loss (kWh/24hrs)*
1.48
1.72
1.92
2.04
2.16
2.32
2.58
1.01
ERP rating
C
C
C
B
C
C
C
A
* Test carried out at 60°C.
Section 2: Technical Data
Page 6
2 TECHNICAL DATA
Содержание HPMONO/IND125