1.1 DESCRiptiOn

The Grant Afinia aluminium radiator range consists of :
• 

Horizontal radiators available in three different heights – 

430mm, 580mm and 680mm

• 

Vertical radiators available in two different heights -1842mm 

and 2042mm.

Refer to Section 2 of these Instructions for radiator dimensions 

and heat outputs.
They are designed to be integrated into low temperature heating 

systems using air source heat pumps, condensing oil, gas and 

biomass boilers, etc. Grant Afinia radiators can be used on either 

open vented or sealed central heating systems. 
Grant Afinia radiators can be used with both copper and plastic 

pipe. Where plastic pipe is used it must be of the oxygen barrier 

type and be the correct class (to BS7291-1) for the application 

concerned. 
On sealed systems, if plastic pipe is to be used, the installer must 

check with the plastic pipe manufacturer that the pipe to be used 

is suitable for the temperatures and pressures concerned. Plastic 

pipe must be Class S to BS7291-1.
Each radiator is supplied with fixing brackets and an installation 

pack. Refer to Sections 1.3 and 1.4 for details.

1.2  StORaGE anD HanDLinG

Grant Afinia radiators should not be stacked in piles higher than 

2.6m (total height). They must be stacked on top of each other on 

the larger side (storage flat=horizontal).
Radiators must be stored inside in a dry and clean environment to 

prevent damage to the radiators and/or their packaging.
Radiators must not be stacked on top of each other without any 

packaging in between them as this may result in damage. A non-

slip plastic sheet should at least be used.
Please ensure that Grant Afinia radiators are protected from 

dirt, rubble, etc. and it is suggested to wait for all other building 

and decorating works to be completed before finally fixing in the 

required location.
Grant recommends that radiators are installed before the plastic 

film is completely removed to protect the paint finish. 

1 intRODUCtiOn

 

1.3  Kit COntEntS

Carefully check that all items supplied with the kit are present as 

detailed below. Please notify your supplier immediately of any 

damage or any missing items.

Horizontal Radiators

Each radiator is supplied with:
• 

2 x Wall mounting brackets (size to suit height of radiator)

 

-

See Section 1.4 (Wall Mounitng Bracket Identification)

• 

1 x Installation pack (see below for contents)

Vertical Radiators

Each radiator is supplied with:
• 

4 x Wall mounting brackets 

• 

1 x Installation pack (see below for contents)

The Installation pack supplied with ALL radiators contains the 

following items that must be fitted to the radiator before mounting 

it on the wall:
• 

2 x 1”x½” BSP reducing bush – right hand thread

• 

2 x 1”x½” BSP reducing bush – left hand thread

• 

1 x ½” BSP plug

• 

1 x ½” BSP radiator vent

• 

1 x Air vent key

1.4  WaLL MOUntinG BRaCKEt  

 iDEntifiCatiOn

Each of the three different heights of Horizontal radiator has its 

own wall mounting bracket.
Each of these three brackets can be easily identified by either 

one, two or three small holes in the outward facing section of the 

bracket, as follows:
• 

430mm radiator - 3 holes

• 

580mm radiator - 2 holes

• 

680mm radiator - 1 hole

Содержание Afinia GALU430 KIT Series

Страница 1: ...UK DOC 0155 Rev 1 2 September 2019 Grant Afinia Aluminium Radiators Horizontal and Vertical Models Installation Instructions ...

Страница 2: ...ide installers on the installation of Grant Afinia Aluminium radiators Please read these instructions thoroughly before starting installation and leave them with the householder for future reference Special Text Formats The following special text formats are used in these instructions for the purposes listed below WARNING Warning of possible human injury as a consequence of not following the instr...

Страница 3: ...echnical specification 5 2 2 Dimensions and weights 5 2 3 Performance data 6 3 Installation 7 3 1 Regulations compliance 7 3 2 Location 7 3 3 Pipe connections 7 3 4 Installation procedure 8 4 Commissioning 11 5 Fault finding 12 6 Care and Use 12 7 Health and Safety Information 13 8 End of Life Information 13 9 Guarantee 13 Contents Page 3 CONTENTS ...

Страница 4: ...st not be stacked on top of each other without any packaging in between them as this may result in damage A non slip plastic sheet should at least be used Please ensure that Grant Afinia radiators are protected from dirt rubble etc and it is suggested to wait for all other building and decorating works to be completed before finally fixing in the required location Grant recommends that radiators a...

Страница 5: ...pth C mm Centres D mm Weight empty kg Weight full kg Water content litres GALU5806KIT 6 580 480 95 500 8 10 10 14 2 04 GALU5808KIT 8 580 640 95 500 10 80 13 52 2 72 GALU58010KIT 10 580 800 95 500 13 50 16 90 3 40 GALU58012KIT 12 580 960 95 500 16 20 20 28 4 08 GALU58014KIT 14 580 1120 95 500 18 90 23 66 4 76 GALU58015KIT 15 580 1200 95 500 20 25 25 35 5 10 Table 2 1c Horizontal Radiators 680mm Hig...

Страница 6: ...2 1 295 GALU58010KIT 10 580 800 380 610 1240 1 295 GALU58012KIT 12 580 960 456 732 1488 1 295 GALU58014KIT 14 580 1120 532 854 1736 1 295 GALU58015KIT 15 580 1200 570 915 1860 1 295 Table 2 3c Horizontal Radiators 680mm High Performance Data Product Code Number of Sections Height A mm Width B mm Output ΔT 20K W Output ΔT 30K W Output ΔT 50K W Exponent n GALU6806KIT 6 680 480 246 432 852 1 348 GALU...

Страница 7: ...ation selection and installation of expansion vessels and ancillary equipment for sealed water systems Code of practice for domestic heating and hot water supply 3 2 Location Grant Afinia radiators should be positioned as follows Minimum distance from floor 100mm Minimum distance below an overhang e g windowsill or shelf 120mm Please refer to Figure 3 1 and Table 3 1 for a representation of these ...

Страница 8: ...e radiator vent to one of the bushes at the top of the radiator and the blanking plug to the remaining open bush after allowing for the location of the radiator valves not supplied TBOE BBOE TBSE Figure 3 2 Pipe Connection Options Fit the radiator valve tails to the radiator bushes using only PTFE tape to seal If any sealant is used great care must be taken to ensure that it does NOT come into con...

Страница 9: ... Front View brackets obscured Grant Afinia Aluminium Radiator 580mm High B C D A E 456 70 94 202 190 94 580 Outline of Radiator Mounting Brackets Fixing Holes Figure 3 4 Fixing hole positions for Horizontal 580mm high radiators Grant Afinia Aluminium Radiator 680mm High B C D A E 540 80 111 225 225 119 680 Mounting Brackets Fixing Holes Outline of Radiator Front View brackets obscured Figure 3 5 F...

Страница 10: ...g holes check for any pipework or electrical wiring within the wall Drill the holes to take suitable wall fixings not supplied Securely fix the wall mounting brackets to the wall ensuring that they are the correct way up Horizontal radiators use only two brackets Vertical radiators use four brackets two at the top and two at the bottom After fixing the brackets use a spirit level to check they are...

Страница 11: ...r system operating temperatures a suitable biocide such as Sentinel R700 should be used in conjunction with the thermal fluid Both the thermal fluid and biocide should be added to the system water when filling the heating system Alternatively Fernox HP 5C can be used This is a suitable thermal fluid that protects against corrosion scale and bacterial growth and also provides frost protection The l...

Страница 12: ... cleaning liquids aerosols or polishing pastes The heated air outlet at the top of the radiator can be periodically vacuumed clean Do not place a shelf directly on top of the radiator Refer to Section 3 2 WARNING IMPORTANT SAFETY INFORMATION Do NOT disconnect the radiator from the heating system unless in response to an emergency or during maintenance work Do NOT use the radiator as part of an ele...

Страница 13: ...anufacturer s guarantee period If your radiator should have a fault within the guarantee period it will be covered under the terms of the guarantee providing that the radiator has been correctly installed and commissioned by a competent person and the fault is not due to tampering debris system water contamination misuse trapped air or the failure of any external components not supplied by Grant E...

Страница 14: ... valves must be provided if and when requested by the Company This guarantee does not cover faults caused by incorrect installation neglect misuse accident or failure to use the radiator in accordance with the manufacturer s installation instructions The balance of the guarantee is transferable Grant Engineering UK Limited must be informed of the new owner s details The Company will endeavour to p...

Страница 15: ...NOTES Page 15 Notes ...

Страница 16: ...Grant Engineering UK Limited Hopton House Hopton Industrial Estate Devizes Wiltshire SN10 2EU Tel 44 0 1380 736920 Fax 44 0 1380 736991 Email info grantuk com www grantuk com ...

Отзывы: