background image

Section 9: Guarantee

page 14

Extent of manufacturer’s guarantee:

The manufacturer’s guarantee does NOT cover the following:
• 

If the radiator has been installed for over 

fifteen years

.

• 

If the radiator has not been installed and commissioned 

by a competent person in accordance with the installation 

instructions.

• 

Fault(s) due to accidental damage, tampering, unauthorised 

adjustment, neglect, misuse or operating the radiator 

contrary to the manufacturer’s installation instructions.

• 

Damage due to external causes such as bad weather 

conditions (flood, storms, lightning, frost, snow, or ice), fire, 

explosion, accident or theft.

• 

Fault(s) due to incorrectly sized expansion vessel(s), 

incorrect vessel charge pressure or inadequate expansion on 

the system.

• 

Heating system servicing, de-scaling or flushing.

• 

Checking and replenishing system pressure. 

• 

Heating system components such as pipes, fittings, pumps, 

valves and controls not supplied by Grant Engineering (UK) 

Limited.

• 

Use of spare parts not authorised by Grant Engineering (UK) 

Limited.

terms of manufacturer’s guarantee:

• 

The Company shall mean Grant Engineering (UK) Limited.

• 

The radiator must be installed by a competent person and 

in full accordance with the relevant Codes of Practice, 

Regulations and Legislation in force at the time of installation.

• 

The manufacture of this radiator is guaranteed for 

fifteen 

years

 from the date of installation². Any work undertaken 

must be authorised by the Company and carried out by a 

competent service engineer

• 

The radiator is operated correctly, in accordance with the 

Installation instructions. 

• 

Grant Engineering (UK) Limited 

strongly recommends

 that 

a Grant Mag-One in-line magnetic filter/s (or equivalent³) 

is fitted in the heating system pipework. This should be 

installed and regularly serviced in accordance with the filter 

manufacturer’s instructions. We reserve the right to ask for 

proof of installation – failure to provide this may result in the 

guarantee becoming invalid.

• 

Proof is provided that the system has been flushed or 

chemically cleaned where appropriate (refer to BS 7593) 

and that the required quantity of a suitable corrosion inhibitor 

added.

• 

Proof of annual heating system servicing⁴ (including the 

checking of any expansion vessels and pressure relief 

valves) must be provided if and when requested by the 

Company.

• 

This guarantee does not cover faults caused by incorrect 

installation, neglect, misuse, accident or failure to use the 

radiator in accordance with the manufacturer’s installation 

instructions.

• 

The balance of the guarantee is transferable. Grant 

Engineering (UK) Limited must be informed of the new 

owner’s details.

• 

The Company will endeavour to provide prompt service in 

the unlikely event of a problem occurring but cannot be held 

responsible for any consequential losses. 

• 

This guarantee applies to Grant Engineering (UK) Limited 

Afinia radiators purchased and installed on the UK mainland, 

Isle of Wight, Channel Islands, Isle of Man and Scottish Isles 

only⁵. Provision of in-guarantee cover elsewhere in the UK is 

subject to agreement with the Company. 

• 

All claims under this guarantee must be made to the 

Company prior to any work being undertaken. Invoices for 

call out/repair work by any third party will not be accepted 

unless previously authorised by the Company. 

• 

Proof of purchase and date of installation, commissioning 

and service documents must be provided on request.

• 

If a replacement radiator is supplied under the guarantee 

(due to a manufacturing fault) the product guarantee 

continues from the installation date of the original radiator 

and 

not

 from the installation date of the replacement.

• 

Breakdown/failure due to system water contamination will not 

be covered by this guarantee.

• 

The replacement of a radiator under this guarantee does 

not include any consequential costs, such as the removal or 

replacement of kitchen units, etc.

• 

The radiator must not be sited in a location where it may be 

subjected to frost.

foot notes:

1.  Your statutory rights entitle you to a one-year guarantee 

period only.

2.  The guarantee period will commence from the date of 

installation, unless the installation date is more than six 

months from the date of purchase, in which case the 

guarantee period will commence six months from the date of 

purchase.

3.  As measured by gauss. The MagOne magnetic filter has a 

gauss measurement of 12,000.

4.  We recommend that your heating system is serviced every 

twelve months (even when the guarantee has expired) to 

prolong the lifespan and ensure it is operating safely and 

efficiently.

5.  The UK mainland consists of England, Scotland and Wales 

only. Please note that for the purposes of this definition, 

Northern Ireland 

is not

 considered part of the UK mainland.

Содержание Afinia GALU430 KIT Series

Страница 1: ...UK DOC 0155 Rev 1 2 September 2019 Grant Afinia Aluminium Radiators Horizontal and Vertical Models Installation Instructions ...

Страница 2: ...ide installers on the installation of Grant Afinia Aluminium radiators Please read these instructions thoroughly before starting installation and leave them with the householder for future reference Special Text Formats The following special text formats are used in these instructions for the purposes listed below WARNING Warning of possible human injury as a consequence of not following the instr...

Страница 3: ...echnical specification 5 2 2 Dimensions and weights 5 2 3 Performance data 6 3 Installation 7 3 1 Regulations compliance 7 3 2 Location 7 3 3 Pipe connections 7 3 4 Installation procedure 8 4 Commissioning 11 5 Fault finding 12 6 Care and Use 12 7 Health and Safety Information 13 8 End of Life Information 13 9 Guarantee 13 Contents Page 3 CONTENTS ...

Страница 4: ...st not be stacked on top of each other without any packaging in between them as this may result in damage A non slip plastic sheet should at least be used Please ensure that Grant Afinia radiators are protected from dirt rubble etc and it is suggested to wait for all other building and decorating works to be completed before finally fixing in the required location Grant recommends that radiators a...

Страница 5: ...pth C mm Centres D mm Weight empty kg Weight full kg Water content litres GALU5806KIT 6 580 480 95 500 8 10 10 14 2 04 GALU5808KIT 8 580 640 95 500 10 80 13 52 2 72 GALU58010KIT 10 580 800 95 500 13 50 16 90 3 40 GALU58012KIT 12 580 960 95 500 16 20 20 28 4 08 GALU58014KIT 14 580 1120 95 500 18 90 23 66 4 76 GALU58015KIT 15 580 1200 95 500 20 25 25 35 5 10 Table 2 1c Horizontal Radiators 680mm Hig...

Страница 6: ...2 1 295 GALU58010KIT 10 580 800 380 610 1240 1 295 GALU58012KIT 12 580 960 456 732 1488 1 295 GALU58014KIT 14 580 1120 532 854 1736 1 295 GALU58015KIT 15 580 1200 570 915 1860 1 295 Table 2 3c Horizontal Radiators 680mm High Performance Data Product Code Number of Sections Height A mm Width B mm Output ΔT 20K W Output ΔT 30K W Output ΔT 50K W Exponent n GALU6806KIT 6 680 480 246 432 852 1 348 GALU...

Страница 7: ...ation selection and installation of expansion vessels and ancillary equipment for sealed water systems Code of practice for domestic heating and hot water supply 3 2 Location Grant Afinia radiators should be positioned as follows Minimum distance from floor 100mm Minimum distance below an overhang e g windowsill or shelf 120mm Please refer to Figure 3 1 and Table 3 1 for a representation of these ...

Страница 8: ...e radiator vent to one of the bushes at the top of the radiator and the blanking plug to the remaining open bush after allowing for the location of the radiator valves not supplied TBOE BBOE TBSE Figure 3 2 Pipe Connection Options Fit the radiator valve tails to the radiator bushes using only PTFE tape to seal If any sealant is used great care must be taken to ensure that it does NOT come into con...

Страница 9: ... Front View brackets obscured Grant Afinia Aluminium Radiator 580mm High B C D A E 456 70 94 202 190 94 580 Outline of Radiator Mounting Brackets Fixing Holes Figure 3 4 Fixing hole positions for Horizontal 580mm high radiators Grant Afinia Aluminium Radiator 680mm High B C D A E 540 80 111 225 225 119 680 Mounting Brackets Fixing Holes Outline of Radiator Front View brackets obscured Figure 3 5 F...

Страница 10: ...g holes check for any pipework or electrical wiring within the wall Drill the holes to take suitable wall fixings not supplied Securely fix the wall mounting brackets to the wall ensuring that they are the correct way up Horizontal radiators use only two brackets Vertical radiators use four brackets two at the top and two at the bottom After fixing the brackets use a spirit level to check they are...

Страница 11: ...r system operating temperatures a suitable biocide such as Sentinel R700 should be used in conjunction with the thermal fluid Both the thermal fluid and biocide should be added to the system water when filling the heating system Alternatively Fernox HP 5C can be used This is a suitable thermal fluid that protects against corrosion scale and bacterial growth and also provides frost protection The l...

Страница 12: ... cleaning liquids aerosols or polishing pastes The heated air outlet at the top of the radiator can be periodically vacuumed clean Do not place a shelf directly on top of the radiator Refer to Section 3 2 WARNING IMPORTANT SAFETY INFORMATION Do NOT disconnect the radiator from the heating system unless in response to an emergency or during maintenance work Do NOT use the radiator as part of an ele...

Страница 13: ...anufacturer s guarantee period If your radiator should have a fault within the guarantee period it will be covered under the terms of the guarantee providing that the radiator has been correctly installed and commissioned by a competent person and the fault is not due to tampering debris system water contamination misuse trapped air or the failure of any external components not supplied by Grant E...

Страница 14: ... valves must be provided if and when requested by the Company This guarantee does not cover faults caused by incorrect installation neglect misuse accident or failure to use the radiator in accordance with the manufacturer s installation instructions The balance of the guarantee is transferable Grant Engineering UK Limited must be informed of the new owner s details The Company will endeavour to p...

Страница 15: ...NOTES Page 15 Notes ...

Страница 16: ...Grant Engineering UK Limited Hopton House Hopton Industrial Estate Devizes Wiltshire SN10 2EU Tel 44 0 1380 736920 Fax 44 0 1380 736991 Email info grantuk com www grantuk com ...

Отзывы: