Page 58
Section 11: Fault Finding
Table 11-1:
Sensor, temperature outdoor (heat pump)
Temperature (°C)
Resistance (kΩ)
0
31
5
24
10
19
15
15
20
12
25
10
30
8.2
35
6.7
40
5.5
45
4.6
50
3.8
55
3.2
Table 11-2:
Sensor, temperature discharge (heat pump)
Temperature (°C)
Resistance (kΩ)
10
100
20
64
35
33
40
27
50
18
80
6.4
Table 11-3:
Sensor, temperature defrost/suction (heat pump)
Sensor temperature DHW tank/thermal store/mix water (Terminal
PCB)
Temperature (°C)
Resistance (kΩ)
0
29
5
23
10
19
15
15
20
12
25
10
30
8.3
35
6.9
40
5.7
45
4.8
50
4.1
55
3.4
Table 11-4:
Sensor, temperature flow and return circulating water
(heat pump)
Temperature (°C)
Resistance (kΩ)
0
25
10
16
20
10
30
7.0
40
4.9
50
3.5
60
2.5
Table 11-5:
Sensor, temperature outdoor (Terminal PCB)
Temperature (°C)
Resistance (kΩ)
-20
107
-15
79
-10
59
-5
44
0
34
5
26
10
20
15
16
20
13
25
10
30
8.0
35
6.5
40
5.3
45
4.3
50
3.6