![grandimpianti GWH11 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/grandimpianti/gwh11/gwh11_manual_2255194044.webp)
The speed field allows you to define the maximum spin speed for the module being pro
-
grammed.
Remember that all the acceleration and deceleration ramps are predetermined by GUIDO
®
ac-
cording to the appliance model and speed set in this field.
The subsequent option allows you to choose whether to carry out distribution or not, i.e. the
spin enabling phase with or without water in the tub. We recommend always setting the value
to YES.
The spin time allows you to set the duration of the spin at the set speed, except for the accel-
eration and deceleration ramps.
As for deceleration, it is possible to select three types of deceleration, where the minimum one
corresponds to the use of the inverter braking function to slow the drum spin down. It reduces
work time of the appliances but wears the inverter component more quickly.
Standard deceleration leaves the drum to slow down by inertia, without any braking action.
This is the factory setting.
Deceleration with water means that the subsequent module involves water load. Therefore,
this water will help brake the drum after the spin cycle.
•
Imbalance
•
Electronic
•
Both
•
Mechanical
The imbalance function consists in three options. The first option manages the imbalance
controlled by the inverter electronically; the second option also manages the imbalance micro
switch; the third option only manages the imbalance micro switch.
•
Restarts
•
No
•
Standard
•
Defined by the user
This function is used to define how GUIDO
®
must behave after imbalance occurs: with the first
option, it does not try to restart spinning; with the second option, it tries for a certain amount
of times; with the third option, the expert laundry operator can set an arbitrary value accord-
ing to the specific requirements.
•
Unroll
•
No
•
Delicate
•
Standard
•
Intense
•
Defined by the user
•
Distribution time
Unrolling consists in drum rotations after the spin phase. These rotations are used to prepare
the laundry to be unloaded and to facilitate this operation for the user.
The meanings of the possible options are now obvious. The "distribution time" sets the time of
this last phase.