29
If a normal AC outlet does not work, check the GFIC on one or more of the
available outlets in the foreward head, or above the microwave to make sure it has
not tripped. Each GFIC outlet can power several other outlets
INVERTER POWER
The Inverter control is located above and to the port side of the helm on the
Magnum Energy panel.
This will provide AC power to the 110-volt receptacle
plugs (i.e. the microwave oven, coffee maker) when the boat is disconnected from
shore power and the inverter button is depressed. The inverter will not provide
power to the water heater or battery charger. The inverter has a capacity of 2500
watts. The AC power fro the inverter supply the following:
a.
Port and starboard base outlets, which will take care of two lamps in
the main cabin, radio, TV and other AC appliances.
b.
The microwave requires about 900 watts, it should be run up to
approximately 10 minutes. For longer periods start the generator.
c.
The refrigeration requires about 10 amps to operate. It will quickly
deplete the batteries if run on the inverter without the main engine
running.
The inverter will act as a battery charger when AC is present
The inverter control panel is on the side of the steering console. To turn on,
push the button and steady green light will come on (it is easy to bump this
switch and accidently turn the inverter off).
The label is INVERT on the panel. This controller also displays Volts, Amps,
Amp hours, etc.
Charge button
On/off inverter button
To use the inverter, push the Inverter button and the INV light should illuminate
indicating it is functioning and there is power to outlets. If no electronics are
drawing any current from the inverter, the display will read “
Searching
”,
effectively putting the inverter on standby, saving power while it’s not in use.