MAINTENANCE / SERVICE
CAUTION:
CONTACT SERVICE PERSONNEL BEFORE REMODELING (MODIFYING THE
SYSTEM), FOR ANNUAL SERVICING/MAINTENANCE, BEFORE EXTENDED PERIODS OF
SHUTDOWN, AND BEFORE START-UP.
Your heating appliance is designed to be maintained and serviced only by your heating
professional. The following sections provide information on maintenance and service-
related activities. In the event a problem occurs consult your heating professional.
•
To achieve maximum efficiency, Conforto Boilers feature
stainless steel removable baffles
No. of
Sections
No. of
Baffles 2
nd
Pass 3
rd
Pass
3
4
2
2
4
4
2
2
5
2
2
2
6
2
2
7
2
2
8
2
2
9
2
2
CONDENSATION
If you have condensation in your chimney, make sure that the chimney size is according
to the tables in CSA B139, NFPA31 and NFPA211, and local codes. The temperature at the
entrance of the chimney can be increased by insulating the flue pipe between the boiler
and the chimney base. If this is not sufficient, consider cutting or removing some flue
baffles in the boiler. BE AWARE THAT REMOVING BAFFLES REDUCES THE UNIT
EFFICIENCY AND A MODIFIED UNIT IS NO LONGER ENERGY STAR APPROVED.
HOMEOWNER SERVICE CAUTION
In the event of a problem with the heating system the homeowner should perform the following
limited activities.
•
Check to make sure that there is fuel in the tank and that oil valves are open.
•
Set the thermostat above existing room temperature.
•
Check for blown fuses or circuit breakers and make sure power switches are in an on position.
•
NEVER TAMPER WITH CONTROLS, WIRING OR PIPING!