3 0 7 T
O U R N A M E N T
8–13
Disconnecting The Dockside Power
1. Switch all circuit breakers at the boat’s AC panel off.
2. Switch the circuit breaker under the starboard gunwale off.
3. Switch the circuit breaker off at the dock outlet.
4. Disconnect the dockside power cable at the dock outlet first.
5. Disconnect the dockside power cable at the boat inlet.
O
PERATION
OF
307 AC E
LECTRICAL
S
YSTEM
Operation w/Shorepower Available
1. Connect shore power. Green LED for shorepower available should be illuminated.
(Reference shore connection procedure)
2. Turn on the AC main breaker.
3. On the remote inverter panel, press the switch down to the “on” position. The “shorepower/
charger” LED will illuminate. The unit is now in “pass through” mode and the inverter
batteries are automatically being charged by the inverter/charger and shorepower is
available for the other accessories.
4. Turn on the battery charger breaker to charge the engine batteries.
5. Turn on the grill breaker.
6. Press the “on” switch on the grill and set to desired temperature.
*
7. If equipped w/optional air conditioner:*
a) Turn on the air conditioner breaker.
b) Turn on the air conditioner by rotating the top knob (on the air conditioner control panel located in the head
compartment) clockwise to “on”.
c) Adjust the temperature control by rotating the bottom knob (on the air conditioner control panel located in
the head compartment) clockwise for cooler and counterclockwise for warmer.
8. Turn off all systems in reverse.
Operation from Inverter Battery Power
1. Turn on battery switch located on the starboard side of the aft rigging compartment.
2. On the remote inverter panel, press the switch down to the “on” position. The “inverter”
LED will illuminate. The unit is now in “inverter” mode and power is being delivered to the
grill and/or air conditioner by the inverter batteries. (AC main remains off during battery
operation).
3. Operate the battery charger, grill and air conditioner as indicated in steps 4 through 7.
4. There is an inverter battery status monitor located ion the AC main electrical distribution
panel. To operate press and hold the test button located on the monitor. A green LED will
appear representing 100%, 50% or depleted. If the unit is in shorepower/pass through mode
when the test button is pressed a red LED will appear indicating “charging”.
Inverter Battery Care
1. The inverter battery or batteries are 8D gel cells. There is no inspection related maintenance
required for a gel battery; however, it is important that they be recharged frequently to
N O T I C E
Keep inlet cover closed tightly when not in use.
Содержание Tournament 307
Страница 8: ...W E L C O M E 1 4 ...
Страница 28: ...P E R F O R M A N C E 4 6 ...
Страница 34: ...I N S T R U M E N T A T I O N A N D S W I T C H E S 5 6 ...
Страница 46: ...M A I N T E N A N C E A N D S E R V I C E 6 12 ...
Страница 52: ...W I N T E R I Z A T I O N A N D S T O R A G E 7 6 ...
Страница 80: ...3 0 7 T O U R N A M E N T 8 28 A C I n v e r t e r S c h e m a t i c ...