Grady-White Boats EXPRESS 360 Скачать руководство пользователя страница 97

3 6 0   E

X P R E S S

8–31

H e l m   A i r   C o n d i t i o n i n g   L a y o u t

AC/DC Panel

Pump Relay

(accessed by panel in

stbd aft berth wall)

Helm Air Thru Hull

Air Control Panel

IN

OU

T

Water Pump

Water Strainer

Air Condition Seacock

(remote arm accessed

through the aft rigging

door behind folding seat)

Air Cond. Raw

Water Supply Hose

4" x 12" 

Supply Grill

14" x 10" 

Return Grill

5" x 10" 
Supply Grill

5" Insulated Duct

5" Insulated Duct

16,000 BTU Air

Conditioning Unit

Condensation

Drain to Sump

Содержание EXPRESS 360

Страница 1: ...ards standards that have served our owners through some truly extraordinary conditions since our first models built in 1958 The seaworthiness and safety of your Grady White is highly dependent on the operation maintenance and care of your boat so please read this manual thoroughly and keep it around for reference If you need further explanation or hands on help don t hesitate to ask the people at ...

Страница 2: ......

Страница 3: ...aterial 2 7 CH A P T E R 3 GE NE R A L I N F O R M A T I O N Fueling 3 1 Fuel System 3 2 Fuel Select Valve 3 3 Pollution Regulations 3 3 Discharge of Oil or Hazardous Substances 3 4 Disposal of Plastics or Garbage 3 4 Environmental Protection Agency 3 5 Trailering 3 5 Predeparture 3 5 Casting Off And Approaching The Dock 3 5 Anchoring 3 5 Towing 3 6 Shallow Water 3 6 General Information On Boat Ha...

Страница 4: ... Paint 6 3 Grady Drives 6 3 Canvas 6 4 Maintenance 6 4 Snaps and Zippers 6 4 Vinyl 6 4 Storage 6 5 Upholstery 6 5 Polyethylene Plexiglass Vinyl 6 5 Scuppers 6 5 Caulking Gasket 6 6 Hardware Stainless Steel Rails 6 6 Hardware Mounting 6 6 Maintenance Procedure For Anodized Aluminum Components 6 6 Fuel System Maintenance 6 7 Fuel Tank Compartment 6 7 Shower Sump 6 8 Batteries 6 8 Inverter Batteries ...

Страница 5: ...eering 8 7 Seacocks 8 8 Shore water 8 8 AC DC Panel 8 8 AC Power Distribution Shore 1 Shore 2 and Generator 8 9 Using Separate Shore 1 and Shore 2 Shore Connections 8 9 Using One Shore Connection Only 8 10 Using Generator Power Only 8 10 Using One Shore Connection and Generator Power 8 10 AC Powered Accessory Switches 8 10 DC Powered Accessory Switches 8 12 Dockside Power 8 13 Connecting The Docks...

Страница 6: ...tioning Layout 8 30 Helm Air Conditioning Layout 8 31 Cockpit Coolers Layout 8 32 Livewell Washdown System Layout 8 33 VacuFlush Head Layout 8 34 Pressurized Freshwater System Layout 8 35 Access Plate And Hull Rigging Tube Locations 8 36 Liner Rigging Tubes 8 37 Safety Labels And Location 8 38 Thru Hull Detail 8 39 Generator Layout 8 40 Bow Thruster Power Assist Layout 8 41 Hardtop Accessories Lay...

Страница 7: ...ater Alarm Diagram 8 59 Stereo System Diagram with Satellite Radio 8 60 TV DVD Diagram 8 61 Electrical Plug Connection Detail 8 62 12 Volt DC Elementary Diagram 8 63 12 Volt DC Distribution Diagram 8 64 120 Volt AC Distribution Diagram 8 65 CH A P T E R 9 LI M IT E D WA R R A N T Y Registration Of Purchase 9 1 Five Year Hull Transferable Warranty 9 1 One Year Material And Workmanship Warranty 9 1 ...

Страница 8: ...T A B L E O F C O N T E N T S ...

Страница 9: ...located on the next to last page of this manual Upon the purchase of your new Grady White Boat the dealer will fill out a warranty card This card will be kept on file at the dealership and at the Grady White factory A copy will be provided for your records and should be kept with other valuable documents for future reference For questions regarding your warranty please contact your dealership DEAL...

Страница 10: ...nspection Refer to the engine s owner s manual for the proper maintenance schedule Grady White Boats has a permanent record of your boat which is retained under its Hull Identification Number HIN Data regarding equipment and accessories as well as dealer shipping information is documented When contacting your dealer concerning warranties or service please have all relevant information such as seri...

Страница 11: ...s which WILL cause severe personal injury or death if the warning is ignored W A R N I N G This symbol alerts you to potentially hazardous situations or unsafe practices that COULD result in severe personal injury or death if the warning is ignored C A U T I O N This symbol alerts you to potentially hazardous situations that MAY result in minor personal injury or cause product or property damage i...

Страница 12: ...W E L C O M E 1 4 ...

Страница 13: ...d and international waters ADDITIONAL RECOMMENDED EQUIPMENT In addition to the required safety equipment there are additional items that will provide an extra margin of safety and convenience for you and your passengers while boating For an extended list of basic gear tools and spare parts reference page 18 of the pamphlet Sportfish Cruisers Yachts Owner s Manual enclosed with this manual Keep too...

Страница 14: ...ish Cruisers Yachts Owner s Manual Rendering Assistance The owner or operator of a vessel is required by law to render all practical or necessary assistance to any person or vessel affected by collision accident or casualty However you are not required to endanger your vessel or passengers to render assistance Accident Reporting Report all boating accidents to your local authorities Federal regula...

Страница 15: ... safe operation in the event of an emergency While boating passengers should be settled in a safe position Use hand holds and rails for steadiness Do not allow bow transom or gunwale riding The captain is ultimately responsible for their passenger s safety Keep your boat speed under control Respect for other boaters and those on shore are common courtesies The boat s operator is responsible for in...

Страница 16: ...o meet the more stringent standards of the NMMA The NMMA is a national trade organization serving all elements of the recreational boating industry including manufacturers of boating equipment With this tag you can have confidence in the safety of your boat This label means that Grady White has designed and built your boat to the ABYC standard H 8 buoyancy in the event of swamping Basic flotation ...

Страница 17: ...h the Coast Guard safety standards NOTE Any boat with an overall length of 26 feet or greater is defined as a yacht by NMMA YACHT CERTIFICATION DESIGN COMPLIANCE WITH NMMA REQUIREMENTS IN EFFECT ON THE DATE OF CERTIFICATION IS VERIFIED MANUFACTURER RESPONSIBLE FOR QUALITY CONTROL NATIONAL MARINE MANUFACTURERS ASSOCIATION MEETS U S EPA EVAP STANDARDS USING CERTIFIED COMPONENTS THIS BOAT COMPLIES WI...

Страница 18: ... the motorwell area Do not board your vessel with the engine s running Also do not occupy the motorwell area with the engine s running Operators need to be aware of the influence of other boats on their vessel as well as the effects they have on neighboring crafts Of primary concern is the operation of an auxiliary generator with boats moored along side each other This situation creates an atmosph...

Страница 19: ...wner s Manual for training options and page 23 for information on charts and maps For further knowledge on boating we advise that you review the following publications Piloting Seamanship And Small Boat Handling Chapman Motor Boating and Sailing Post Office Box 2319 F D R Station New York New York 10022 Available on CD ROM Pleasure Boating And Seamanship US Coast Guard Auxiliary 306 Wilson Road Oa...

Страница 20: ...S A F E T Y 2 8 ...

Страница 21: ...ticulate contaminants that may be loosened from the fuel system due to the solvent nature of alcohol blended fuels Carry spare fuel filters with a 10 micron rating on your boat for emergency replacement if required Before Fueling Shut down all engines Turn battery select switch es to off to insure that all fans lights etc are off Close all ports hatches windows and engine compartments to prevent f...

Страница 22: ...y If you are experiencing fuel flow problems there is a simple method to determine if the problem is in your fuel system or your engine Connect a six gallon 22 7 L portable tank to your engine If the problem persists the likely cause is with the engine itself If the problem goes away the source must be in the boat s fuel system One component that should be inspected if a restriction occurs is the ...

Страница 23: ...REGULATIONS The U S Coast Guard defines restrictions on the discharge of oil or hazardous substances and plastics or garbage in the Federal Requirements for Boating and Boating Safety You should have received this pamphlet when you registered your boat Detailed below is a summary of those regulations You should read the pamphlet and become familiar with any local restrictions where you operate you...

Страница 24: ...e MARPOL ANNEX V is the Act to prevent pollution from ships and other vessels Federal regulations prohibit the discharge of plastic garbage anywhere in the marine environment Plastic includes but is not limited to synthetic fishing nets ropes lines straws six pack holders styrofoam cups and lids bottles buckets and plastic bags These regulations also restrict the disposal of other types of garbage...

Страница 25: ...you want the trailer to go Familiarize yourself with this manual and all aspects of your boat prior to initial launch At the launch site go through a pre launch checklist The list should be suited to your specific needs Trailering and relative information can be found on page 94 in Sportfish Cruisers Yachts Owner s Manual PREDEPARTURE See the checklist on page 35 in Sportfish Cruisers Yachts Owner...

Страница 26: ...d always have someone at the wheel since the boat may swing off course Start the tow off slowly a steady pull at a moderate speed should be used It is important to keep the slack out of the propeller area Watch the action of the towing boat If excessive slack develops in the towline and contact is obvious turn in either direction to avoid hitting the stern SHALLOW WATER Most boats that become grou...

Страница 27: ... on the display Make a log of this type of information and have it available when using your boat Other statistics you may want to determine could include the following Minimum speed for effective steering Turning radius at different speeds Response to steering at low speeds Accelerating and deceleration rates Time and distance to bring the boat to a stop at different speeds Control of the boat in...

Страница 28: ...ck and hull join Hatch an opening in the deck to provide access below Headroom vertical distance between the floor and over head structure or canopy ceiling Hull major component that provides a watertight platform buoyant enough to float a craft and its load Keel the major longitudinal member of a hull the lowest external portion of the boat Knot a measurement of speed equal to nautical miles per ...

Страница 29: ...hings when reading this gauge The accuracy of your gauge varies with the attitude of your boat in the water trim or list The fuel pickup tube inside the gas tank is not capable of withdrawing all of the fuel from the tank For these reasons never operate your boat at extremely low fuel levels Fuel Economy This feature indicates the engine s fuel economy in miles per gallon Fuel Consumption This fea...

Страница 30: ...hich may not start the engine A reading of 13 to 15 volts when the engine is running is normal Readings over 15 volts may indicate regulator problems Low or fluctuating readings may indicate loose connections or trouble in the regulator and alternator circuit Cooling Water Temperature with Warning This feature indicates the temperature of the cooling water circulating through the engine and warns ...

Страница 31: ...l from the tank For these reasons never operate your boat at extremely low fuel levels Fuel Economy This feature indicates the engine s fuel economy in miles per gallon Fuel Consumption This feature indicates the fuel consumption in gallons since the feature was last reset Fuel Flow This feature indicates the fuel flow through the engine s in gallons per hour Low Fuel Warning Indicator This featur...

Страница 32: ... fluctuating readings may indicate loose connections or trouble in the regulator and alternator circuit Cooling Water Temperature with Warning This feature indicates the temperature of the cooling water circulating through the engine and warns you when the temperature exceeds the recommended operating range indicated by your engine owner s manual Should you receive this warning immediately shut of...

Страница 33: ... is not capable of withdrawing all of the fuel from the tank For these reasons never operate your boat at extremely low fuel levels Fuel Economy This feature indicates the engine s fuel economy in miles per gallon Fuel Consumption This feature indicates the fuel consumption in gallons used by the all engines together since the feature was last reset Fuel Flow This feature indicates the fuel flow t...

Страница 34: ...ng is normal Readings over 15 volts may indicate regulator problems Low or fluctuating readings may indicate loose connections or trouble in the regulator and alternator circuit Cooling Water Temperature with Warning This feature indicates the temperature of the cooling water circulating through the engine and warns you when the temperature exceeds the recommended operating range indicated by your...

Страница 35: ...tion or questions on the accessories included on your boat More detailed descriptions of switch functions are located in Chapter 8 of this manual This drawing represents a generic switch panel layout Actual panels will differ depending on the boat model and optional accessories installed during manufacturing AFT BILGE ACC WIPER MACERATOR M FWD BILGE ELEC BOX HORN NAV ANCHOR COCKPIT LIGHT LIVEWELL ...

Страница 36: ...I N S T R U M E N T A T I O N A N D S W I T C H E S 5 8 ...

Страница 37: ... passengers and fuel are added This extra load will affect the performance of your boat according to the distribution of the weight Another type of extra load that could affect performance is the accumulation of water in the bilge Keep the bilge dry to eliminate this type problem Marine Growth Maximum performance is obtained only when your hull bottom is clean Marine growth on the bottom of the bo...

Страница 38: ... consumption Diameter and pitch are the two basic dimensions of a propeller Diameter is the distance across the circle made by the blade tips as the propeller rotates Pitch is the theoretical not accounting for slippage forward distance the propeller would move in one revolution An example of a propeller dimension would be 14 X 17 for a propeller having a diameter of 14 35 6cm and a pitch of 17 43...

Страница 39: ...nuals are included with the Owner s Packet ENGINE WARRANTY A warranty registration card is included with all engine manuals It should be completed and returned to the engine manufacturer as soon as possible D A N G E R Do not inhale exhaust fumes Exhaust contains carbon monoxide a dangerous gas which is potentially lethal W A R N I N G Do not attempt to service any engine or drive component withou...

Страница 40: ...osed to the elements If you operate in salt water areas lubrication is extremely important and you should make frequent inspections for corrosion Hydraulic Steering Hydraulic steering systems require regular preventative maintenance for continued safe and reliable operation The oil level in the helm pump must be maintained within acceptable operating levels A low oil level will allow air to get in...

Страница 41: ... the control lever aft of the neutral position to reverse the shift mechanism and create a reverse thrust of the propeller Increase the aft movement to increase the reverse thrust Remember that propellers are designed for maximum forward thrust so reverse thrust will not be as efficient All controls have a neutral safety mechanism This mechanism will not allow the engine to start when the control ...

Страница 42: ...eration the center engine will follow the port lever for shift and throttle Other modes can be obtained by using the engine selector button on the back of the control C A U T I O N The braking action causes a wake which may wash over the transom and flood the boat if the vessel is moving too fast Allow engine RPMs to decrease before shifting into reverse Also under certain conditions not allowing ...

Страница 43: ...hough gel coat has a hard smooth surface it does contain microscopic pores that will allow surface discoloration if not kept clean Maintenance Normal exterior finish maintenance of your Grady White is similar to the care you would give your automobile Do not use caustic highly alkaline cleaners or those containing ammonia These cleaning agents may darken gel coat The resulting stain is a chemical ...

Страница 44: ...nty of water and sand curves in the same direction Dry the area to make sure all the discoloration has been removed Repeat this process if necessary Buff using a polishing compound suitable for fiberglass an electrically or pneumatically operated buffer at low speed 1750 2250 RPM and an 8 inch 20 3cm lamb s wool pad When buffing is complete wash away compound with clear water and dry the area Once...

Страница 45: ...ccidentally scratched repair it immediately Damaged areas can be repaired with the Touch Up Kit included with your product when it shipped from the factory Please follow the instructions for using the Touch Up Kit Your bracket is made from marine grade aluminum Should you desire to coat your bracket with anti fouling or bottom paint chose a paint that is intended for aluminum Follow the paint manu...

Страница 46: ... steam press or dry in an electric or gas dryer This will damage the canvas fabric Water repellent was applied to your canvas during manufacturing The repellent may have diminished after extended cleaning Re treatment of the fabric is recommended Do not use wax based products Use a water based repellent like Apseal or Uniseal Scotchguard is effective for short term use only Snaps and Zippers To pr...

Страница 47: ...structure Screws are then installed through the underside of the bolster to hold them in place Most cabin cushions are removable and may be dry cleaned or steam cleaned POLYETHYLENE PLEXIGLASS VINYL In the cockpit area of your boat plexiglass and vinyl are used for trim and polyethylene is used for the toe rails and rod racks Routine maintenance for vinyl should include regular cleaning with soapy...

Страница 48: ...UM COMPONENTS Lean Bars Rod Holders T top and Hardtop Frames Outriggers Etc Due to the nature of anodized aluminum and the harsh exposure conditions of the marine environment it is important to follow a required maintenance procedure Failure to follow a preventative maintenance procedure will most likely result in aluminum pitting These parts must be washed periodically with a very mild soap and w...

Страница 49: ...teriorated hoses clamps or connections immediately Fuel filter water separators should be replaced at least annually FUEL TANK COMPARTMENT The fuel tank compartments need to be rinsed periodically especially when used in a salt water environment Dirt accumulation attracts salt creating salt crystals Salt crystals can corrode most metal surfaces if left untreated over a period of time To help prote...

Страница 50: ... applications If your boat is equipped with batteries not installed at the factory consult with the battery manufacturer for proper care and maintenance instructions and the engine manufacturer for appropriate battery specifications Wet cell batteries must be secured in a non metallic tray to contain electrolyte spills An insulated boot should cover battery terminals Keep terminals clean by scrubb...

Страница 51: ...se severe burns and create dangerous sparks which could result in personal injury and or property damage C A U T I O N When disconnecting and reconnecting battery cables the black cable must be connected to the negative terminal and the red cable must be connected to the positive terminal Reversing these connections will immediately damage your system Never disconnect the battery when the engine i...

Страница 52: ...Smith Replacement Bulb G4 14V 10W T3 Xenon Dome Light large cabin Light Manufacturer Daniel R Smith Replacement Bulb G4 14V 20W T3 Xenon Reduced Glare Hardtop Mast Light Light Manufacturer Perko Replacement Bulb Perko 71 DP CLR Dome Light small cabin Light Manufacturer Perko Replacement Bulb Perko 337 013 DP Top Mount Light Windshield Light Manufacturer Perko Replacement Bulb Perko 338 DP2 CLR Red...

Страница 53: ...iode fixtures do not have bulbs and are not serviceable LED s have extremely long life and should not need replacement during the life of the boat In the event of damage or malfunction the entire light assembly should be replaced See your Grady White dealer for replacement LED lights ...

Страница 54: ...Float Switch 16 ga Brown Orange 3 0 Fuse Block Washdown Pump 12 ga Orange Brown 15 0 Accessory Panel Water Pressure Pump 12 ga Orange Blue 15 0 Accessory Panel Power Assist Pump ignition 16 ga Purple 5 0 Yamaha ignition panel in line Power Assist Pump main 8 ga Red 50 0 Battery Compartment Anchor Windlass 232 up Anchor Windlass 232 up 6 ga Red 35 0 At helm near switch all but 306 306 in console ri...

Страница 55: ...l Pumps Aft Bilge Pump 330 336 Fwd Rule 1500 16 ga Brown 8 0 Accessory Panel Auto Float Switch Aft 16 ga Brown White 8 0 Battery Select Box Fwd Bilge Pump Rule 1100 16 ga Brown Black 6 0 Accessory Panel Auto Float Switch Forward 16 ga Brown Red 6 0 Battery Select Box Head Pump Discharge 14 ga Orange Gray 10 0 AC DC Panel Head Pump Vaccum 14 ga Orange Red 10 0 AC DC Panel Livewell Pump Sentry 1100 ...

Страница 56: ...Pink Red 5 0 AC DC Panel Hardtop Negative Main 10 ga Black Blue N A Negative Bus Hardtop Power Lead Main 10 ga Red Blue 40 0 Console fuse panel 305 only Horn 12 ga Orange White 10 0 Accessory Panel Hydraulic Trim Tabs 14 ga Orange 20 0 Fuse Block Refrigerator 10 ga Orange Yellow 15 0 AC DC Panel Seakey Float 300 only 16 ga White Red N A N A Stereo 16 ga Red 10 0 AC DC Panel TV DVD 10 ga Red Green ...

Страница 57: ... Center Port Starboard 14 ga Orange Purple 14 ga Orange Green 14 ga Orange Black 20 0 Helm Accessory Panel Washer Solenoid Valves 14 ga Orange Pink 10 0 Helm Accessory Panel Miscellaneous 12 Volt Accessory Outlets 10 ga Red Orange 15 0 Fuse Block Amplifier 10 ga Red 10 0 Fuse Block Accessory Negatives Branch Black 1 N A N A Accessory Negatives Mains 2 0 or 6 ga Black N A N A AC DC Panel Meter Nega...

Страница 58: ...M A I N T E N A N C E A N D S E R V I C E 6 16 ...

Страница 59: ...ould remain as close to ground level as possible If slings are necessary for lifting or transporting they should be in proper condition and tied together to prevent any movement separating or slipping which could cause damage to the boat If fork lifts are used to move the boat the forks should be padded contoured to match the hull bottom and in a secure location under the hull in alignment with th...

Страница 60: ...nd hatches Check hinges for corrosion Lubricate hinges as necessary The T 9 metal protection product was developed by Boeing Aviation for long term protection of aircraft It works by coating and penetrating fasteners and fixtures displacing moisture and drying to a clear wax film that lubricates and protects metals for months T 9 can be used to protect deck hardware engines electronics and fishing...

Страница 61: ...moved from deck pump out lines BATTERIES Fully charge the batteries before storing A weak battery loses its charge more rapidly than a strong battery Coat the battery terminals with grease to prevent corrosion ENGINES See your engine Operator s Manual regarding the winterizing procedures Follow instructions carefully and your engine will withstand severe weather conditions Change all filters Check...

Страница 62: ... fuel tank compartment instructions in the maintenance and service section Tanks should be kept filled when the boat is not in use to reduce the accumulation of moisture and condensation Add stabilizer to fuel that won t be used in 60 90 days Use fuel stabilizer specifically designed for alcohol blended fuel if using E10 gasoline A B Fuel Tank ...

Страница 63: ...syphon Valve Pick up Elbow Pink Main or Pink White Aux Wire to Fuel Gauge Green Ground Wire to Battery Green Jumper Aluminum Tanks Only Ground Tab Aluminum Tanks Only Manufacturer s Label Hull Harness To Engine Fuel Sending Unit Fill Vent Stainless Clamps Stainless Clamps Deck Fill Vent Fitting 5 8 Vent Hose USCG Type B2 1 1 2 Fill Hose USCG Type A2 ...

Страница 64: ...nd reapply anti fouling bottom paint if necessary Leave as much equipment and personal effects as possible off the boat until after launch and final check PRIOR TO LAUNCHING Start your own personalized list of items to check and perform prior to placing your boat in the water The following list will give you some ideas and suggestions Check all gear and replace if necessary Check thru hull fitting...

Страница 65: ...e fuel system including lines fittings connections valves and filters for leaks Connect to shore power if installed Check all electrical equipment lights hot water heater air conditioning system battery charger operation etc Check operation of toilet reference manufacturer s manual Test run engines and generator if installed as directed in manufacturer s manual ...

Страница 66: ...W I N T E R I Z A T I O N A N D S T O R A G E 7 8 ...

Страница 67: ...4 cm Engine Shaft Length O B 25 64 cm Center 30 76 cm Transom Width 11 4 3 5 m Dry Weight 14 919 Lbs 6767 kg Steering Type Hydraulic Tilt w Power Assist Steering Hose Lengths Helm to power assist 13 4 m Compensating line 12 3 7 m Power assist to tees 15 4 6 m Tee to stbd cylinder 6 1 8 m Tee to port cylinder 9 2 7 m Maximum Outboard HP 1050 HP 783 kW O p t i o n a l F e a t u r e s ACCESSORIES Cus...

Страница 68: ...ft which opens and closes the raisable electronics box at the helm A circuit breaker located above this switch provides over current protection for this circuit Hardtop Lights optional This momentary switch activates the multi colored recessed downlights Depressing the switch one time turns the lights on Subsequent pressing of the switch will cycle the lights through the colors Press and hold for ...

Страница 69: ...tivates the underwater lights A circuit breaker located above this switch provides over current protection for this circuit Washdown This switch activates the washdown system A circuit breaker located above this switch provides over current protection for this circuit ...

Страница 70: ...ing Color Fuse Breaker on page 6 12 for recommended breaker amperages Switch labels are available from your dealer for non factory installed options OTHER SWITCHES Trim Tilt The trim tilt switch is located on the throttle control Trim changes the angle of thrust of the engine reference Trim on page 5 1 Tilt raises the drive unit for trailering Trim Tab These switches control the hydraulic trim tab...

Страница 71: ...ories such as cellular phones and spotlights See 12 Volt DC Accessory Locations on page 8 44 for a layout of all 12 volt DC accessories BATTERY SELECT SWITCH The Express 360 is equipped with five batteries One of the batteries is designated for the bow thruster and the steering power assist pump It is located behind the fold out helm table The other four batteries are located in the aft rigging ar...

Страница 72: ...stem and can turn the pump off when the bilge is dry When a switch is in the off position the pump is off unless activated by the float switch BILGE PUMP LOCATIONS Your boat has two bilge pumps One is located in the aft bilge rigging area and can be accessed through the aft rigging lid beneath the access panel in the generator subfloor The second is in the rigging area under the aft berth This pum...

Страница 73: ...estigate to determine the source of water entry Also confirm your bilge pumps are working properly If the situation cannot be quickly resolved contact your dealer and remove the boat from the water See 12 Volt DC High Bilge Water Alarm Diagram on page 8 59 for wiring detail POWER ASSIST HYDRAULIC STEERING The engine ignition switches must be on for this system to function The power assist hydrauli...

Страница 74: ...umbing by passes the freshwater pump installed on your boat Therefore the freshwater switch on the DC panel does not have to be on when connected to shore water All freshwater features on your boat are available for use when connected to shore water without depleting the supply in your water tank AC DC PANEL The Express 360 AC DC panel is located on the aft wall of the cabin AC and DC powered swit...

Страница 75: ...rcuit Use the two amp meters on the panel to manage the load on each circuit the amp readings should not exceed 30 amps on either meter ________________________ 15A for international boats outside North America GASOLINE VAPORS CAN EXPLODE RESULTING IN INJURY OR DEATH BEFORE STARTING GENERATOR RUN BLOWER WHEN VESSEL IS OPERATING BELOW CRUISING SPEED CHECK GENERATOR COMPARTMENT BILGE FOR GASOLINE VA...

Страница 76: ...oad group 1 and load group 2 are being powered by the generator the amp readings on each amperage meter must be added together to properly manage the load The sum of the two amperage readings should not exceed 70 amps Using One Shore Connection and Generator Power To use one shore connection along with generator power first ensure shore 2 is connected to shore power and the generator is operating ...

Страница 77: ...oup 1 switch activates the GFCI cabin outlet located forward of the refrigerator in the V berth area See Outlets on page 8 19 for more details about the outlets Cockpit Coolers Switch This load group 2 switch provides power to the control unit for the refrigeration unit used to cool the cockpit coolers Refer to Freezer Refrigerated Box System on page 8 18 for more detail concerning the operation o...

Страница 78: ...s on the helm and cockpit accessory panels See Switch Panels on page 8 2 for more detail concerning these panels Blower Switch This switch operates the bilge blower See Blower on page 8 16 for more information Cabin Lights Switch This switch provides power for all the lights located in the cabin Refer to Cabin Lights on page 21 for more information on the individual switches within the lighting sy...

Страница 79: ...hore 1 Shore 2 and Generator on page 8 9 for more detail The AC panel allows for distribution to the various appliances and outlets See the 12 Volt DC Elementary Diagram on page 8 63 for wiring specifics and 120 Volt AC Accessory Locations on page 8 45 for component locations Connecting The Dockside Power Either Shore 1 or Shore 2 1 Verify that the external power source is a 3 wire grounded system...

Страница 80: ... some monitoring functions To learn more about these monitoring functions reference the Fischer Panda owner s manual included in your owner s packet Amperage Requirements The generator provides sufficient power to operate most accessories at the same time A list of amperage requirements for all AC accessories is provided below Use the amp meters and volt meter on the AC panel to properly manage th...

Страница 81: ... automatic pre glow phase 6 Switch the generator transfer switch on and confirm the correct voltage is being supplied from the generator using the volt meter on the AC panel 7 Switch on desired loads Stopping the Generator 1 Switch off all loads and the generator transfer switch Stabilize the generator temperature by running for five minutes without load 2 Press the generator RUN STOP button on th...

Страница 82: ...erator or dockside power must be in use with load group 2 energized The air conditioner switch on the AC DC panel activates the unit s control pad located in the dinette area The air cooler pump switch must also be on and the air condition seacock must be open to supply the unit with raw water The thermostatic control is similar to household units Supply vents are located in the galley the dinette...

Страница 83: ...t recharge check these fuses and replace as necessary See this charger s Operation Manual in your Owner s Packet for further information on the charger See 12 Volt DC Elementary Diagram on page 8 63 and 120 Volt AC Distribution Diagram on page 8 65 for wiring detail Bow Thruster Charger This single bank battery charger is located beneath the aft starboard helm seat just forward of the bait station...

Страница 84: ...n AC power only therefore the generator or dockside power must be in use with load group 2 energized The helm air conditioner switch on the AC DC panel activates the unit s control pad located in the galley area near the cabin door The air cooler pump switch must also be on and the air conditioner seacock must be open to supply the unit with raw water The thermostatic control is similar to househo...

Страница 85: ...e next accessory Microwave The dockside power must be connected or the generator must be operating with load group 1 energized for the microwave to function A foam block has been provided to protect the glass platter inside the microwave when the boat is in motion Ensure this block is in place when the microwave is not in use remove before operation Refer to the microwave operation and maintenance...

Страница 86: ...st be turned parallel to the supply line prior to using the ice maker To winterize the ice maker turn the valve perpendicular to the supply line allowing the small amount of water in the ice maker line to drain out through the valve and into the bilge Then cycle the ice maker one time to remove any remaining water from the unit For additional information regarding troubleshooting maintenance or de...

Страница 87: ...wo recessed lights in the V berth The three lights above the mirrored cabinet in the head are controlled by a wall switch on the forward head wall The overhead light in the aft berth and the rail light in the galley have switches built into each light See 12 Volt DC Lighting Diagram on page 8 50 for wiring detail Cockpit Shower To operate the cockpit showers located in the starboard rigging statio...

Страница 88: ... low light situations and have individual breakers located above them Refer to Switch Panels on page 8 2 for information regarding the operation of switches included on this panel Head And Discharge Pump Reference VacuFlush Head System on page 8 26 for information on the operation of these components Head Shower To use the head shower the freshwater switch located on the AC DC panel must be activa...

Страница 89: ...m becoming clogged See Cleaning on page 6 1 for maintenance information Similar to a bilge pump the sump pump is activated automatically by a float switch to discharge the collected water overboard via a thru hull The shower sump also collects and dischargers condensation from the air conditioners and should be turned on whenever they are in use Stereo The stereo is a marine Sirius ready AM FM rec...

Страница 90: ...rator will walk you through the initial setup process You will need the ESN number for your tuner a major credit card your boat in a location where the antenna is not blocked from receiving signal and the Sirius tuner tuned to channel 184 You will find the ESN number attached to the warranty card for the tuner included in the owner s packet You may also obtain this number using your Sirius ready s...

Страница 91: ...e port side press the starboard trim tab switch toward bow down Press the port trim tab switch toward bow down to correct a starboard list This will tend to lower the bow by pulling the higher side to a level position If your bow is already in a low position and your tabs are down you may correct a listing condition by pressing the trim tab switch toward bow up This will cause the low side to rise...

Страница 92: ... bow A hose with a spray nozzle attached may be used intermittently without turning the switch off in the same fashion as a home yard hose with a nozzle The washdown pump has an internal pressurization switch that will maintain water pressure as needed until the switch is turned off at the switch panel The pump is located in the forward starboard rigging compartment and may be accessed via the acc...

Страница 93: ...rge 3 Engage the pump using the key switch in the Tank Manager panel on the outboard head wall Turn the switch to the start position momentarily and release The key will return to the auto off position The discharge pump will run until the Tank Manager panel indicates the tank is empty and turn off automatically 4 Turn the key to the off position 5 Close the discharge seacock when the tank is empt...

Страница 94: ...cessary twisting action characteristic of artificial bait Instructions For installation and use reference the sheet included in your Owner s Packet Care And Maintenance Outriggers should be washed with freshwater mild soap and a soft cloth Never use abrasive cleaners on outriggers A periodic waxing is suggested if your outriggers are exposed to salt water The wax will provide a protective coating ...

Страница 95: ...P R E S S 8 29 InformationalDrawings F u e l S y s t e m 180 Gallon 681 L Fuel Tank Fuel Select Valves in battery select box Three Fuel Filters Primer Bulbs in motorwell Fuel Fill Vent 190 Gallon 719 L Fuel Tank ...

Страница 96: ...sulated Duct 5 Insulated Duct 4 Teak Grill 4 Insulated Duct 3 Insulated Duct Pump Relay accessed by panel in stbd aft berth wall Water Pump Water Strainer Air Condition Seacock remote arm accessed through the aft rigging door behind folding seat Air Cond Raw Water Supply Hose 16 000 BTU Air Conditioning Unit accessed by removing cover board in forward dinette seat Air Condition Thru Hull Condensat...

Страница 97: ...m Air Thru Hull Air Control Panel IN O UT Water Pump Water Strainer Air Condition Seacock remote arm accessed through the aft rigging door behind folding seat Air Cond Raw Water Supply Hose 4 x 12 Supply Grill 14 x 10 Return Grill 5 x 10 Supply Grill 5 Insulated Duct 5 Insulated Duct 16 000 BTU Air Conditioning Unit Condensation Drain to Sump ...

Страница 98: ...ulated Suction Line 1 4 Liquid Line 3 8 Insulated Suction Line Water Pump Water Strainer Pump Relay PR Refrigeration Relay RR access relays solenoid valves and condensing unit by panel in port aft berth wall panel Air Conditioner Seacock remote arm accessed through the aft rigging door behind folding seat Port Cockpit Cooler Aft Fishbox ...

Страница 99: ... Pump pump strainer accessed through door on berth wall panel Washdown Seacock accessed by removing cover board beneath cushion 1100 gph 4164 lph Livewell Pump Seacock remove cover board beneath cushion to access Livewell Overflow Drain 47 5 Gallon 182 L Livewell Washdown Outlet Water Inlet Washdown Outlet ...

Страница 100: ...acuflush Head Vent Deck Pump out Discharge Seacock accessed by removing the cover board beneath cushion Reducer Discharge Pump Vacuum Tank w Pump Holding Tank Vacuflush system accessed through door in berth wall panel Vacuflush Tank Manager Panel Water Level Gauge ...

Страница 101: ...mulator Tank accessed through panel in port aft berth wall panel Galley Sink Pull out Faucet Head Sink Pull out Faucet Vacuflush Head Windshield Washer Solenoid Vavles 11 Gallon 42 L Water Heater accessed by removing port deckwing insert Head Shower Refrigerator Freezer w Ice Maker Bait Station Faucet Shore Water Inlet Refrigerator Shut off Valve Fresh Water Washdown ...

Страница 102: ...a 2 X 108 H I 1 X 145 1 ea 3 X 89 C 4 ea J A 4 pcs B 2 pcs D 2 pcs E 2 pcs F J A 2 pcs F G 2 pcs H E I 6 6 Access Plate 6 6 6 6 6 6 6 4 4 6 Access Plate 4 Access Plate 6 Access Plate vertical beneath helm seat 6 Access Plate 6 Access Plate vertical beneath head sink 6 Access Plate 4 Access Plate vertical on TV cabinet 6 6 Access Plate vertical inside trash can compartment 3 0 m 2 6 m 1 0 m 79 cm 6...

Страница 103: ...3 6 0 E X P R E S S 8 37 L i n e r R i g g i n g Tu b e s 3 x 80 3 x 36 3 x 30 A B C 2 0 m 91 cm 76 cm Description A C B ...

Страница 104: ...ide CO can cause brain damage or death Engine and generator exhaust contains odorless and colorless carbin monoxide gas Signs of carbon monoxide poisoning include nausea headache dizziness or drowsiness and lack of consciousness Get fresh air if anyone shows signs of carbon monoxide poisoning See Owner s Manual for information regarding carbon monoxide poisoning CO CO CO CO CO CO CO CO CO CO CO CO...

Страница 105: ... Condensor Drain M N O Description Scupper Drains Livewell Drain Overflow Gen Exhaust Fwd Bilge Air Conditioner Discharge Head Sink Drain Galley Sink Drain Head Vent Aft Bilge Aft Fishbox Drain Stbd Sink Drain Shower Sump K D H E G J A L C B I F Description N M L A D J I F H O A K E B C G ...

Страница 106: ...Reservoir Generator Seacock Intake Water Strainer 23 Gallon 87 L Diesel Fuel Tank Exhaust Thru Hull 70A DPDT Breaker Power Supply to AC DC Panel Siphon Break Exhaust Muffler Fischer Panda 8 Mini Generator Forward CO Monitor Aft CO Monitor All aft generator components are accessed by raising the aft generator rigging lid 100A ANL Fuse on Battery Select Box ...

Страница 107: ...ol Bow Thruster Battery Access battery fuses by removing folding helm table Bow Thruster Motor accessed by removing stbd storage sump and two drawer cabinet Emergency Shut off Switch Power Assist Pump Accessed by panel in stbd berth wall panel 400A Fuse and Holder Bow Thruster 50A Fuse and Holder Power Assist ...

Страница 108: ...elm table where it connects to the aft hull harness The main 12V DC positive and negative wiring for the hardtop route to the DC positive and DC negative bus bars located behind the AC DC panel Hardtop DC Negative Bus Accessed through 4 access plate Dual Trumpet Horn 6 Water Resistant Stereo Speakers Dome Light with white red bulbs Mast Light Spreader Lights ...

Страница 109: ... L a y o u t 6 1 2 Water Resistant Stereo Speakers In Hardtop 6 1 2 In ceiling Stereo Speaker Above Dinette 6 1 2 In ceiling Stereo Speaker Above Galley Stereo Stereo Remote Sirius Tuner behind microwave Sirius Antenna 6 1 2 Speakers Amp ...

Страница 110: ...d by raising generator rigging lid and opening access plate in generator subfloor Blower accessed by raising generator rigging lid Main 12V DC Negative Bus secured to aft side of bulkhead beneath aft fishbox Main Batteries Battery Select Box 12V Accessory Outlet Trim Tab Pump Anchor Windlass with Foot Controls and Solenoid Head Vent Shower Sump Stereo Power Assist Pump 1100 gph 4164 lph Livewell P...

Страница 111: ... Dual Burner Glass Top Stove Convection Microwave Phone Jack GFCI Cockpit Outlet GFCI Galley Outlet Pump Relay PR Refrigeration Relay RR Battery Charger accessed by removing aft drop in box Bow Thruster Charger GFCI Cockpit Outlet GFCI Head Outlet with Cover Coolers Condensing Unit solenoid valves relays unit accessed through door in port aft berth wall panel Coolers Solenoid Valves 16 000 BTU Air...

Страница 112: ...ARD ENGINE POSITION 1 CENTER ENGINE POSITION 1 OR 2 PORT ENGINE POSITION 2 DEDICATED BATTERY SYSTEM FOR BOW THRUSTER 6 GA RED CENTER ENGINE ISOLATOR LEAD 10A 400A 4 0 RED BOW THRUSTER POS 8 GA BLACK POWER ASSIST 4 GA BLACK STBD ENGINE NEG 4 GA BLACK CENTER ENGINE NEG 4 GA BLACK PORT ENGINE NEG 2 0 BLACK MAIN ACCY NEG 6 GA GREEN AC GROUNDING BUS 6 GA BLACK JUMPER 35A 4 GA BLACK GENERATOR NEG 2 0 BL...

Страница 113: ... ENGINE CRANKING LEAD RECOMMENDED SWITCH OPERATION STARBOARD ENGINE POSITION 1 PORT ENGINE POSITION 2 DEDICATED BATTERY SYSTEM FOR BOW THRUSTER 6 GA RED STBD ENGINE ISOLATOR LEAD 10A 400A 4 0 RED BOW THRUSTER POS 8 GA BLACK POWER ASSIST 4 GA BLACK STBD ENGINE NEG 4 GA BLACK PORT ENGINE NEG 2 0 BLACK MAIN ACCY NEG 6 GA GREEN AC GROUNDING BUS 6 GA BLACK JUMPER 35A 4 GA BLACK GENERATOR NEG 2 0 BLACK ...

Страница 114: ...NICAL INTERLOCK TO PREVENT SIMULTANEOUS CLOSURE AC AMPS AC AMPS BATTERY CHARGER BOW THURSTER CHARGER MICROWAVE STOVE REFRIGERATOR GALLEY OUTLET CABIN OUTLET WATER HEATER HEAD OUTLET COCKPIT OUTLET AIR COOLER PUMP AIR COND COCKPIT COOLERS HELM AIR COND 10A 5A 20A 25A 15A 15A 15A 15A 15A 15A 5A 30A 15A 30A CURRENT TRANSFORMER CURRENT TRANSFORMER GENERATOR SELF LIMITING LOAD GROUP 1 LOAD GROUP 2 SPDT...

Страница 115: ...5 16 GA BLK 10 GA ORG 16 GA WHT GRN 16 GA WHT GRN W S VENT SW 16 GA BLK W S VENT ACTUATOR ELEC BOX LIFTING RAM 16 GA BLK ELEC BOX SW 16 GA WHT 16 GA W 10 GA ORG 16 GA BLK HORN SW 12 GA ORG WHT 10 GA ORG 12 GA ORG WHT 12 GA BLK 3 5 7 8 9 10 11 AFT BILGE SW 2 P7 8 P5 1 P7 3 P5 5 P7 4 P4 2 P4 1 P5 6 P4 3 P4 5 R G HORN 10A CB 10A CB 10A CB 6A CB 10A CB 15A CB BEHIND AC DC PANEL MAIN ACC DC NEG BUS 10 ...

Страница 116: ...LU GRN 16 GA BLU GRN 16 GA BLU GRN 16 GA BLK 16 GA BLU GRN FWD ROPE LTS SWITCH 16 GA BLU GRN 16 GA BLK 16 GA BLK 16 GA BLK 16 GA BLK 16 GA BLU GRN 16 GA BLU GRN VANITY LTS SWITCH 16 GA BLU GRN 16 GA BLK AFT BERTH LTS W SW GALLEY RAIL LT W SW 16 GA BLK 16 GA BLU GRN 2 3 4 6 7 8 MAIN ACC DC NEG BUS LIGHTS TB 5 W W W W W W W W W W W W W W W W W W W AFT NEAR BATTERIES AFT NEAR BATTERIES BEHIND AC DC P...

Страница 117: ...ATO ATO 15A FU ACCESSORY OUTLET 3 10 GA R ORG 10 GA BLK 16 GA BLK 16 GA BRN GN HEAD VENT FU 3A ATO ATO 20A FU TRIM TABS SEE DWG 360 DC 9 14 GA ORG 14 GA BLK SEE DWG 360 DC 1 1 LINE 9 2 3 4 5 6 7 8 NOTES 1 INDICATES MULTI CONDUCTOR CABLE 9 16 GA BLU GRY FU 5A ATO SEE DWG 360 DC 8 LINE 7 HEAD VENT SW IN HEAD AFT NEAR BATTERIES SEE DWG 360 DC 1 1 LINE 4 ATO 10A FU FUSION AMP 10 GA REDE 10 GA BLK ATO ...

Страница 118: ...GA ORG PORT WIPER MOTOR FROM DWG 360 DC 3 LINE 11 FROM DWG 360 DC 3 LINE 11 STBD WIPER MOTOR 14 GA ORG 14 GA ORG BLK 14 GA BLK FROM DWG 360 DC 3 LINE 11 14 GA ORG PNK 14 GA ORG PNK 14 GA ORG PNK 14 GA ORG PNK 14 GA BLK 2 3 4 5 14 GA BLK WASHER SOLENOID VALVES 1 16 GA BLK P3 4 P3 2 P3 7 P3 8 P3 1 P3 3 P3 6 P10 5 16 GA ORG 16 GA ORG 16 GA ORG 14 GA BLK 16 GA ORG 16 GA ORG 16 GA ORG 16 GA ORG 360 DC ...

Страница 119: ...1 1 2 3 4 2 GA R D1 A2 WINDLASS SOLENOID D2 2 GA R 2 GA R 18 GA BRN UP 14 GA BLU ORG 18 GA R 18 GA R 14 GA GRN ORG DOWN 18 GA BLU 14 GA R UP DOWN 14 GA BLK 18 GA BLU ORG 18 GA GRN ORG 14 GA R 14 GA R 14 GA R 5 WINDLASS HELM SWITCH FROM DWG 360 DC 1 3 LINE 32 P4 8 P4 7 P4 6 WINDLASS MOTOR WINDLASS FOOT CONTROLS 5A CB 360 DC 7 ...

Страница 120: ...RED 14 BLU WHT 16 BLU GRY 2 3 4 5 6 7 16 GA BLK 14 BLK 16 BLK SEE DWG 360 DC 3 LINE 8 SEE DWG 360 DC 5 LINE 9 SEE DWG 360 DC 10 LINE 5 10 GA BLK BLU 12V DC HARD TOP NEG BUS HARD TOP DOME LIGHT W SW SPREADER LIGHTS MAST LIGHT 14 BLU WHT P6 1 P6 10 P6 4 W W W SEE DWG 360 DC 1 1 LINE 4 R W BEHIND AC DC PANEL IN HARD TOP 360 DC 8 ...

Страница 121: ... CONDUCTOR CABLE 2 SEE DWG 360 DC 5 LINE 7 14 GA BLK 14 GA ORG BENNETT TRIM TAB HYDRAULIC PUMP BENNETT EIC Relay Module 14 GA ORG SEE DWG 360 DC 11 LINE 9 14 GA BLK STBD ACTUATOR BENNET CABLE GRN BENNET CABLE RED PORT ACTUATOR BENNETT EIC SWITCH BENNET BLUE CABLE BENNET BLUE CABLE BENNET HPU CABLE 16 GA ORG 16 GA PUR 14 GA BLK 360 DC 9 ...

Страница 122: ... C B L IV E W E L L S W 1 6 G A B L K 1 2 G A B L K W A S H D O W N S W W A S H D O W N P U M P 1 2 G A O R G B R N 1 2 G A O R G B R N 1 0 G A O R G 1 0 G A O R G 1 4 G A B L U W H T 1 4 G A B L U W H T S P R E A D E R L IG H T S S W 3 4 5 T O D W G 3 6 0 D C 8 L IN E 6 1 6 G A B L U R 1 6 G A B L K 2 P 8 6 P 8 5 P 7 6 P8 1 P 8 2 P 7 7 P 8 3 F R O M D W G 3 6 0 D C 1 1 L IN E 4 R L IV E W E L L L...

Страница 123: ...POS 12V DC IGNITION BUS NEG BLK Y SEE ENGINE S OWNER S MANUAL SEE DWG 360 DC 1 2 LINE 24 16 GA PUR 16 GA ORG Y BLK PORT ENGINE SEE DWG 360 DC 1 3 LINE 36 STBD ENGINE 1 IGNITION SWITCH PANEL SEE ENGINE OWNER S MANUAL SEE DWG 360 DC 1 1 LINE 12 LINE NO YAMAHA CABLE SEE DWG 360 DC 1 2 LINE 17 CENTER ENGINE SEE DWG 360 DC 9 LINE 1 16 GA PUR 11 12 13 3 2 6 7 YAMAHA CABLE ATC 5A FU FU 5A ATC 360 DC 11 ...

Страница 124: ... W GN AIR COND UNIT SEE COMPONENT OWNER S MANUAL FOR INTERNAL WIRING AIR COND CONTROL PANEL DATA CABLE CONDENSING UNIT SEE COMPONENT OWNER S MANUAL FOR INTERNAL WIRING 3C 14 GA TEMP CONTROLLER PORT COOLER SEE COMPONENT OWNER S MANUAL FOR INTERNAL WIRING TEMP CONTROLLER AFT FISHBOX SEE COMPONENT OWNER S MANUAL FOR INTERNAL WIRING 3C 14 GA 3C 14 GA 2C 14 GA 2C 14 GA PORT SOLENOID AFT SOLENOID LINE N...

Страница 125: ...DWG 360 DC 1 1 LINE 4 1 4 16 GA R PNK HIGH BILGE WATER ALARM BUZZER 3 SEE DWG 360 DC 1 1 LINE 3 R 16 GA BLK NOTES 1 SEE LAYOUT DRAWINGS FOR LOCATIONS OF COMPONENTS HIGH BILGE WATER ALARM LT ON SWITCH 5 2 16 GA BRN PNK 16 GA R W 16 GA BRN PNK 16 GA R PNK HIGH BILGE WATER ALARM SWITCH BEHIND AC DC PANEL 16 GA R 16 GA BLK 360 HWA 1 ...

Страница 126: ... SPEAKER P10 1 P10 2 P10 4 P10 3 16 GA SPEAKER 16 GA SPEAKER WHT P11 6 P11 5 DINETTE SPEAKER P7 12 P7 13 P7 11 P7 10 6 7 8 SEE DWG 360 DC 1 1 LINE 4 BEHIND AC DC PANEL NOTES 1 DC NEGATIVES SPLICED TOGETHER AS FOLLOWS DECK HARNESS 1 STEREO DINETTE DOME LT HORN WIPER GALLEY RAIL LT GALLEY DOEM LT KENWOOD STEREO SEE OWNER S MANUAL FOR COMPONENT DETAIL KENWOOD SIRIUS SATELLITE TUNER KENWOOD DIN CABLE ...

Страница 127: ...61 T V D V D D i a g r a m LINE NO NOTES 1 INDICATES MULTI CONDUCTOR CABLE 1 2 3 4 SHORE CABLE TV INLET FLAT PANEL TELEVISION RG6 COAXIAL A B SELECTOR SWITCH RG6 COAXIAL BROADCAST ANTENNA RG6 COAXIAL 3C RCA CABLE DVD PLAYER ...

Страница 128: ... N Lock II 15 Aft Hull to Helm Sw Panel P6 Mate N Lock II 15 Aft Hull to Hardtop P7 Mate N Lock II 15 Aft Hull to Fwd Hull P8 Mate N Lock II 9 Aft Hull to Cockpit Sw Panel P9 Mate N Lock II 4 Aft Hull to Battery Select Panel P10 Mate N Lock II 6 Deck to Fwd Hull P11 Mate N Lock II 15 Fwd Hull to Stereo P12 Mate N Lock II 4 Inst Panel to Helm Sw Panel P13 Mate N Lock II 4 Sto Rem Ext to Sto P14 Mat...

Страница 129: ...s and electronics equipment All repairs are subject to prior written authorization by Grady White Boats Incorporated NO BOAT IS TO BE SENT TO THE GRADY WH1TE FACTORY AND NO REPAIRS MADE WITHOUT SUCH WRITTEN AUTHORITY The Five Year Structural Hull Warranty is transferable to the second and subsequent owners for the remainder of the five 5 years from the date of delivery to the original purchaser Th...

Страница 130: ... of cosmetic surface finishes including gel coat cracking crazing blistering discoloration chalking or fading chrome plated or painted metal aluminum and stainless steel finishes plastics or acrylic materials windshields glass breakage all vinyl upholstery and canvas instruments and gauges and leakage around windshields windows hatches and other apertures Failure of the owner to use maintain or st...

Страница 131: ...RIOR WRITTEN AUTHORIZATION FROM GRADY WHITE BOATS INCORPORATED THESE WARRANTIES ARE EXPRESSLY MADE IN LIEU OF ALL OTHER WARRANTIES DURATION OF ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE SHALL BE LIMITED TO AND COINCIDENT WITH THE DURATION OF THESE EXPRESSED WARRANTIES THIS WARRANTY SHALL NOT BE VALID UNLESS THE FACTORY WARRANTY POSTCARD IS PROPERLY EXE...

Страница 132: ...L I M I T E D W A R R A N T Y 9 4 ...

Страница 133: ..._____________________________ Date Purchased ________________ About Your Boat 1 What type of power is your boat equipped with Single OB Dual OB Inboard Outboard 2 What engine brand does your boat have Johnson Mercury Evinrude Yamaha Volvo Other 3 Engine horsepower total if twin power ________ 4 Is your new Grady White the first boat you ve ever owned Yes Please skip to question 5a No Please tell u...

Страница 134: ... Sportfishing Boating World Florida Sportsman Power Motoryacht Wall Street Journal Boats U S Offshore Saltwater Sportsman Other ____________________ 10 What is your age Under 25 25 34 35 44 45 54 55 64 65 or older 11 Which of the following best describes your educational background Some High School Some College or Technical Some Post Graduate Work High School Graduate College Graduate Post Graduat...

Страница 135: ......

Страница 136: ......

Отзывы: