Prime/Flush
14
311164M
Prime/Flush
1.
Follow
2.
Remove tip and tip guard from gun.
3.
Flushing only:
If desired, remove built-in fluid filter
(present on some models). Reinstall filter cap after
removing fluid filter.
4.
Place suction tube in a compatible fluid (if priming)
or solvent (if flushing).
Zinc sprayers only:
Place return tube in a compati-
ble fluid (if priming) or solvent (if flushing). Open
return line valve.
5.
Turn regulator adjustment knob (G) counterclock-
wise until it stops, and gauge (E) reads zero.
6.
Open bleed type master air valve (B).
Zinc sprayers only:
When clean solvent or fluid flows
from return tube, close return line valve. Pump will
stall.
7.
Prime or flush hose and gun:
a.
Disengage gun trigger lock.
b.
Trigger gun into grounded pail until a steady
stream comes from gun.
If flushing
, trigger gun
for 10-15 seconds.
c.
Engage trigger lock.
8.
If priming, equipment is now ready to spray; go to
If flushing, proceed with step 9.
G
E
-
B
NOTE: If using an AA gun, increase air pressure
by turning gun regulator clockwise.
TI5048a
TI8727a