Operation

Using

Using

Using the

the

the Elevator

Elevator

Elevator

(included

(included

(included in

in

in some

some

some packages)

packages)

packages)

Refer to the Elevators and Pump Supports
Manual 306287 for detailed information about
using the elevator.

The elevator air control has three settings:
RAISE, OFF, and RUN.

• RAISE allows the elevator to be raised and

disables the agitator and feed pump air.

• OFF turns off all air pressure. If the elevator is

raised, OFF will lower the elevator.

• RUN enables the agitator and feed pump air.

A restrictor valve on the elevator air line slows
the elevator for safe operation.

Using

Using

Using the

the

the Agitator

Agitator

Agitator

Make sure that the agitator shut-off valve is in
the CLOSED position and the regulator is turned
all the way down.

If used, turn the elevator control to RUN.

Turn the agitator shut-off valve to the OPEN
position.

Slowly open the regulator valve to increase
agitator speed until the desired speed is
reached.

NOTE:

NOTE:

NOTE: Always maintain moderate agitator speed.
Excessive agitator speed may cause vibration,
foaming of fluid, and increased wear on parts.

NOTICE

NOTICE

NOTICE

To prevent air motor failure and possible
damage to equipment, always keep the air
motor properly lubricated.

The Xtreme-Duty Agitator is provided
with an air line lubricator to aid in proper
maintenance. Fill the lubricator with Air Motor
Oil (202659) and set the lubricator feed rate
at 1 drop of oil per minute for high speed
or continuous duty usage. Do not overfeed
oil or exhaust air may become contaminated.
To manually lubricate the air motor, see

Lubricating the Agitator Air Motor, page 16

.

Using

Using

Using the

the

the Feed

Feed

Feed Pump

Pump

Pump

(included

(included

(included in

in

in some

some

some packages)

packages)

packages)

Fluid under high pressure can be injected
through the skin and cause serous injury. To
reduce the risk of an injury from injection,
splashing fluid, or moving parts, follow the
Pressure Relief Procedure whenever you:

• are instructed to relieve the pressure,

• stop spraying,

• check or service any of the system

equipment,

• or install or clean the spray tips.

Refer to the feed pump manual and component
manual for any dispense equipment used
for specific operation and pressure relief
instructions.

Feed

Feed

Feed Pump

Pump

Pump Pressure

Pressure

Pressure Relief

Relief

Relief Procedure

Procedure

Procedure

For feed pump pressure relief information, refer
to the appropriate feed pump manual.

Related Manuals, page 3

.

14

3A4032D

Содержание Xtreme-Duty 25A598

Страница 1: ...allon gallon gallon 200 200 200 liter liter liter open open open headed headed headed drums drums drums For For For professional professional professional use use use only only only Important Importan...

Страница 2: ...e 13 Setup 13 Using the Elevator included in some packages 14 Using the Agitator 14 Using the Feed Pump included in some packages 14 Maintenance 15 Agitator Fasteners 15 Agitator Blades 15 Air Motor M...

Страница 3: ...Mounting Support Support Support Feed Feed Feed Pump Pump Pump Approvals Approvals Approvals 25A599 25A599 25A599 AGITATOR ON DRUM COVER Xtreme Duty Agitator 25A598 Drum cover with recirculation kit H...

Страница 4: ...or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use...

Страница 5: ...ZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read Safety Data Sheet SDS to know the specific hazards of the fluids you are using...

Страница 6: ...Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in use Check equi...

Страница 7: ...gitator air motor and gear reducer B Xtreme Duty agitator blade C Agitator shaft and coupler D Stainless steel drum cover F Recirculation tube G Ground wire with clamp H Feed pump strainer Key Key Key...

Страница 8: ...the ground wire G to the ground connector GC on the side of the agitator and or drum cover Connect the clamp end of the ground wire to a true earth ground For an additional ground wire and clamp order...

Страница 9: ...f injury from being crushed by equipment do not go under the elevator when it is raised Mount the drum cover as described in the Elevators and Pump Supports Manual 306287 The elevator must be in the d...

Страница 10: ...below for the hole mounting pattern and minimum clearance required Attaching Attaching Attaching the the the Blades Blades Blades 1 Slide the agitator blade assembly B1 onto the shaft C1 positioned so...

Страница 11: ...RAISE NN Ref Ref Ref Description Description Description AR Air Restrictor Elevator Speed EC Elevator Control Selector AS Agitator Shut Off Valve FP Feed Pump Shut Off Valve SA Supply Air Inlet LB Agi...

Страница 12: ...ther end to the inlet of the proportioning system or other equipment A fluid drain valve is required to connect to the fluid outlet of the pump See the pump manual for details The drum cover also has...

Страница 13: ...the risk of serious injury from moving parts and splashing fluid always shut off the agitator before you raise check or repair the agitator 1 Before turning on supply air make sure all valves are in t...

Страница 14: ...revent air motor failure and possible damage to equipment always keep the air motor properly lubricated The Xtreme Duty Agitator is provided with an air line lubricator to aid in proper maintenance Fi...

Страница 15: ...n become electrostatically charged when stirred or blended Dried material could allow static buildup and interfere with grounding To prevent fire and explosion ground equipment and do not allow materi...

Страница 16: ...ator Air Air Air Motor Motor Motor NOTICE NOTICE NOTICE Not lubricating the air motor will cause air motor failure Install air line lubricator and air line filter If an air line lubricator is not inst...

Страница 17: ...in 1 18 155699 FITTING elbow 3 8 in 1 19 113333 VALVE ball vented 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 20 16F151 FITTING connector 1 21 17M563 BRACKET guard cou...

Страница 18: ...9 FITTING elbow 3 8 in 1 19 113333 VALVE ball vented 1 20 16F151 FITTING connector 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 21 17M563 BRACKET guard coupling 1 22 15...

Страница 19: ...lvent and paint fumes can ignite or explode Material can become electr ostatically char ged Use equipment only in well ventilated ar ea Eliminate all ignition sour ces Gr ound all equipment in work ar...

Страница 20: ...16P923 COUPLER adapter 1 917 100828 COUPLING flexible 1 918 16T063 COLLAR mounting 1 919 116940 SCREW SHCS 5 16 18 2 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 920 181...

Страница 21: ...ription 25A599 25A599 25A599 25A600 25A600 25A600 25A601 25A601 25A601 25A602 25A602 25A602 25A603 25A603 25A603 25A604 25A604 25A604 Qty Qty Qty 101 25A598 Xtreme Duty agitator X X X X X X 1 102 17J0...

Страница 22: ...0 1 sst X 1 109 119922 FITTING nipple 3 4 in X X X X X 1 110 248829 KIT regulator feed pump X X X X X 1 111 256653 KIT fluid strainer X X X X X 1 112 217382 HOSE 3 4 in 10 ft X X X X X 1 113 128689 PL...

Страница 23: ...mum Recommended Speed 1000 in lb 100 psi air pressure 113 N m 0 7 MPa 7 bar air pressure Stall Torque at Maximum Air Inlet Pressure 1120 in lb 127 N m Span Diameter of Agitator Blades 13 75 in 349 mm...

Страница 24: ...Y WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND...

Отзывы: