307160

Service

Fig. 3

06640

1

11

8

7

1

1

12

3

6

5

T

4

9

1

Torque to 40–50 ft-lb (54–68 N

S

m)

NOTE: 

To service the displacement pump, refer to

manual 308043, supplied.

NOTE: 

To service the hydraulic motor, refer to manual

308158, supplied.

Disassembly 

(See Fig. 3)

WARNING

To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the

Pressure Relief Procedure

 on page 8.

1.

Flush the pump with a compatible solvent, if pos-
sible. Stop the pump at the bottom of its stroke.

Relieve the pressure

.

2.

Disconnect the hoses from the pump. Plug the
hydraulic lines to prevent contamination. Remove
the pump from its mounting and clamp it in a vise.

3.

Remove the upper cotter pin (1). Unscrew the
coupling nut (7). Unscrew the three tie rod 
locknuts (3), then unscrew the three tie rods (6)
from the hydraulic motor (11). Carefully pull the
displacement pump (12) away from the motor (11).

4.

Remove the lower cotter pin (1). Loosen the
locknut (4). Unscrew the connecting rod (9) from
the displacement rod (T).

Reassembly 

(See Fig. 3)

1.

Screw the three tie rods (6) into the motor (11).
Torque to 40–50 ft-lb (54–68 N

S

m).

2.

Screw the connecting rod (9) into the displacement
rod (T). Install the cotter pin (1) and tighten the
locknut (4).

3.

Guide the displacement pump (12) onto the tie
rods (6).

4.

Install the locknuts (3) on the tie rods. Torque the
nuts to 40–50 ft–lb (54-68 N

S

m).

5.

Tighten the coupling nut (7). Insert the upper cotter
pin (1) through the coupling (8)

6.

Connect the hoses to the pump. Run the pump
slowly to be sure it runs smoothly and does not
bind. If necessary, adjust the displacement pump
tie rods and locknuts (see manual 308043), or the
tie rods (6) and locknuts (3) which attach the
motor, to eliminate binding.

7.

Reconnect the ground wire to the motor.

Содержание Viscount II 210313

Страница 1: ...untR II Pump 1500 psi 10 3 MPa 103 bar Maximum Hydraulic Input Pressure 1000 psi 7 MPa 69 bar Maximum Pump Outlet Pressure Model 210313 Series D With Severe Duty Displacement Pump Severe Duty displace...

Страница 2: ...for its intended purpose If you are not sure call your Graco distributor D Do not alter or modify this equipment D Check equipment daily Repair or replace worn or damaged parts immediately D Do not e...

Страница 3: ...tip guard and the trigger guard on the gun valve when spraying dispensing D Be sure the gun valve trigger safety operates before spraying dispensing D Lock the gun valve trigger safety when you stop s...

Страница 4: ...operating this equipment electrically disconnect all equipment in the spray dispense area D Before operating this equipment extinguish all open flames or pilot lights in the spray dispense area D Do...

Страница 5: ...th ground Order part num ber 237569 Grounding Clamp and Wire D Fluid and hydraulic hoses Use only grounded hoses with a maximum of 500 ft 150 m combined hose length to ensure grounding continuity D Hy...

Страница 6: ...pressurizing the motor or displacement pump and a pressure and temperature compensated flow control valve G to prevent the motor from running too fast and possibly damaging itself D A pressure reducin...

Страница 7: ...ydraulic Return Shutoff Valve Pressure Gauge Flow Control Valve Pressure Reducing Valve Accumulator Drain Line from pressure reducing valve Hydraulic Supply Line Hydraulic Power Supply Ground Wire Wet...

Страница 8: ...he spray tip or hose is completely clogged or that pressure has not been fully relieved after following the steps above very slowly loosen the tip guard retaining nut or hose end coupling and relieve...

Страница 9: ...fore each use Turn on the hydraulic power supply Open the return line shutoff valve E Slowly open the hydraulic supply shutoff valve S Run the pump slowly until all air is pushed out of the lines and...

Страница 10: ...th a compatible solvent Corrosion Protection WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 CAUTION...

Страница 11: ...ime or flush Clogged fluid line valves etc Clear Piston check valve needs adjustment Adjust See manual 308043 Packing nut too tight Loosen Loose packing nut or worn throat pack ings Tighten packing nu...

Страница 12: ...then unscrew the three tie rods 6 from the hydraulic motor 11 Carefully pull the displacement pump 12 away from the motor 11 4 Remove the lower cotter pin 1 Loosen the locknut 4 Unscrew the connecting...

Страница 13: ...n insert 3 4 101936 NUT hex jam 3 4 10 1 5 158674 O RING nitrile rubber 1 6 167911 ROD tie 7 177 8 mm long shoulder to shoulder 3 7 168210 NUT shouldered 1 8 168211 COUPLING connecting rod 1 9 168212...

Страница 14: ...mm 23 2 585 mm 3 4 npt inlet 1 npt outlet 2 npt fluid inlet 1 1 2 npt fluid outlet Mounting Hole Layout 06595 gasket 161806 four 0 437 11 1 mm holes on 10 5 267 mm bolt circle 45_ 90_ 1 38 34 9 mm ra...

Страница 15: ...bar 331 psi 2 3 MPa 23 bar 600 psi 4 1 MPa 41 bar 397 psi 2 7 MPa 27 bar 700 psi 4 8 MPa 48 bar 463 psi 3 2 MPa 32 bar 800 psi 5 5 MPa 55 bar 530 psi 3 6 MPa 36 bar 900 psi 6 2 MPa 62 bar 596 psi 4 0...

Страница 16: ...h of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or propert...

Отзывы: