WARNING

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

D

This equipment is for professional use only.

D

Read all instruction manuals, tags, and labels before operating the equipment.

D

Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.

D

Do not alter or modify this equipment.

D

Check equipment daily. Repair or replace worn or damaged parts immediately.

D

Do not exceed the maximum working pressure stated on the equipment or in the 

Technical Data

for your equipment. Do not exceed the maximum working pressure of the lowest rated component
in your system.

D

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the 

Tech-

nical Data

 section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

D

Handle hoses carefully. Do not pull on hoses to move equipment.

D

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose
Graco hoses to temperatures above 66

_

C (150

_

F) or below –40

_

C (–40

_

F).

D

Wear hearing protection when operating this equipment.

D

Do not move or lift pressurized equipment.

D

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

Содержание Viscount II 210313

Страница 1: ...untR II Pump 1500 psi 10 3 MPa 103 bar Maximum Hydraulic Input Pressure 1000 psi 7 MPa 69 bar Maximum Pump Outlet Pressure Model 210313 Series D With Severe Duty Displacement Pump Severe Duty displace...

Страница 2: ...for its intended purpose If you are not sure call your Graco distributor D Do not alter or modify this equipment D Check equipment daily Repair or replace worn or damaged parts immediately D Do not e...

Страница 3: ...tip guard and the trigger guard on the gun valve when spraying dispensing D Be sure the gun valve trigger safety operates before spraying dispensing D Lock the gun valve trigger safety when you stop s...

Страница 4: ...operating this equipment electrically disconnect all equipment in the spray dispense area D Before operating this equipment extinguish all open flames or pilot lights in the spray dispense area D Do...

Страница 5: ...th ground Order part num ber 237569 Grounding Clamp and Wire D Fluid and hydraulic hoses Use only grounded hoses with a maximum of 500 ft 150 m combined hose length to ensure grounding continuity D Hy...

Страница 6: ...pressurizing the motor or displacement pump and a pressure and temperature compensated flow control valve G to prevent the motor from running too fast and possibly damaging itself D A pressure reducin...

Страница 7: ...ydraulic Return Shutoff Valve Pressure Gauge Flow Control Valve Pressure Reducing Valve Accumulator Drain Line from pressure reducing valve Hydraulic Supply Line Hydraulic Power Supply Ground Wire Wet...

Страница 8: ...he spray tip or hose is completely clogged or that pressure has not been fully relieved after following the steps above very slowly loosen the tip guard retaining nut or hose end coupling and relieve...

Страница 9: ...fore each use Turn on the hydraulic power supply Open the return line shutoff valve E Slowly open the hydraulic supply shutoff valve S Run the pump slowly until all air is pushed out of the lines and...

Страница 10: ...th a compatible solvent Corrosion Protection WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 CAUTION...

Страница 11: ...ime or flush Clogged fluid line valves etc Clear Piston check valve needs adjustment Adjust See manual 308043 Packing nut too tight Loosen Loose packing nut or worn throat pack ings Tighten packing nu...

Страница 12: ...then unscrew the three tie rods 6 from the hydraulic motor 11 Carefully pull the displacement pump 12 away from the motor 11 4 Remove the lower cotter pin 1 Loosen the locknut 4 Unscrew the connecting...

Страница 13: ...n insert 3 4 101936 NUT hex jam 3 4 10 1 5 158674 O RING nitrile rubber 1 6 167911 ROD tie 7 177 8 mm long shoulder to shoulder 3 7 168210 NUT shouldered 1 8 168211 COUPLING connecting rod 1 9 168212...

Страница 14: ...mm 23 2 585 mm 3 4 npt inlet 1 npt outlet 2 npt fluid inlet 1 1 2 npt fluid outlet Mounting Hole Layout 06595 gasket 161806 four 0 437 11 1 mm holes on 10 5 267 mm bolt circle 45_ 90_ 1 38 34 9 mm ra...

Страница 15: ...bar 331 psi 2 3 MPa 23 bar 600 psi 4 1 MPa 41 bar 397 psi 2 7 MPa 27 bar 700 psi 4 8 MPa 48 bar 463 psi 3 2 MPa 32 bar 800 psi 5 5 MPa 55 bar 530 psi 3 6 MPa 36 bar 900 psi 6 2 MPa 62 bar 596 psi 4 0...

Страница 16: ...h of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or propert...