background image

All written and visual data contained in this document reflects the latest product information available at the time of publication. 

Graco reserves the right to make changes at any time without notice.

Original instructions.

 This manual contains English. MM 3A3381

Graco Headquarters: Minneapolis

International Offices: Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA

Copyright 2015, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Rev E, November 2019

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in 
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty 
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by 
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written 
recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty 
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of 
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with 
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or 
maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of 
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned 
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will 
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED 
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy 
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or 
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT 
MANUFACTURED BY GRACO
. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to 
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these 
warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or 
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the 
negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, 
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la 
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite 
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visi

www.graco.com

.

For patent information, see 

www.graco.com/patents.

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

Содержание Viscount 17E230

Страница 1: ...similar fluids For professional use only See page 3 for model information including maximum working pressure Important Safety Instructions Read all warnings and instructions in this manual Save these...

Страница 2: ...00cc or 2000cc with Sealed 4 Ball Lower 17 Viscount I Pumps Models 17K964 17K965 17E230 17E232 17E233 17E234 17E236 17E237 17E238 17E240 and 17E241 750cc 1000cc 1500cc or 2000cc with 4 Ball Lower Open...

Страница 3: ...ralife 17E234 VISCOUNT 1 1500cc Open 225 1 6 16 0 npt CS Chrome Chrome 17E235 VISCOUNT 1 1500cc Sealed 225 1 6 16 0 tri clamp SST Ultralife Ultralife 17E236 VISCOUNT 1 1500cc Open 225 1 6 16 0 npt SST...

Страница 4: ...ential static sparking Ground all equipment in the work area See Grounding instructions Never spray or flush solvent at high pressure Keep work area free of debris including solvent rags and gasoline...

Страница 5: ...ute hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Compl...

Страница 6: ...nk use a ground wire and clamp Dispense valve ground through a connection to a properly grounded fluid hose and pump Fluid supply container follow local code Object being sprayed follow local code Sol...

Страница 7: ...ring that there is sufficient clearance for fluid connections and for servicing the lower 4 Drill four 7 16 in 11 mm holes using the bracket as a template Use any of the three mounting hole groupings...

Страница 8: ...ulic Return Line For Viscount I Plus motors the hydraulic outlet on the motor is 7 8 in 22 mm 37 flare Use a mini mum 5 8 in 16 mm ID hydraulic return line K For Viscount II motors use a minimum 7 8 i...

Страница 9: ...Surge Tank J 10 Micron Return Filter K Hydraulic Return Line L Hydraulic Supply Line M Drain Line N Pressure Reducing Valve P Hydraulic Pressure Gauge R Return Line Shutoff Valve S Supply Line Shutof...

Страница 10: ...G Surge Tank J 10 Micron Return Filter K Hydraulic Return Line L Hydraulic Supply Line M Drain Line N Pressure Reducing Valve P Hydraulic Pressure Gauge R Return Line Shutoff Valve S Supply Line Shuto...

Страница 11: ...shutoff valve D downstream of the pump The pump should stall against pressure NOTE In a circulation system the pump operates con tinuously until the power supply is shut off In a direct supply system...

Страница 12: ...on reservoir and filter cleaning and periodic changes of hydraulic fluid Stall Test Perform a stall test periodically to ensure the piston seal is in good working condition and prevent system pres su...

Страница 13: ...o output Improperly installed ball check valves Check and repair Pump operates erratically Exhausted fluid supply Refill and re prime pump Held open or worn ball check valves Check and repair Worn pis...

Страница 14: ...ng the drain bottle to the tie rod 3 Loosen the coupling nut 5 and remove the collars 6 Remove the coupling nut from the piston rod R Unscrew the lock nuts 4 from the tie rods 3 Separate the motor 1 a...

Страница 15: ...75 80 ft lb 102 109 N m f Continue to step 2 2 Assemble the coupling nut 5 over the piston rod R 3 Orient the lower 2 to the motor 1 Position the lower on the tie rods 3 4 If you are reusing lock nut...

Страница 16: ...75 N m Lubricate threads Torque to 75 80 ft lb 102 109 N m Torque to 15 17 ft lb 20 23 N m Fill cavity with grease 1 2 3 4 6 7 1 2 3 Models with Open Wet Cup Lowers Viscount II motor shown Models with...

Страница 17: ...l see detailed parts list in manual 333022 1 17K656 For model 17K963 17K659 For model 17E231 17K658 For model 17E235 17K657 For model 17E239 3 17C261 TIE ROD 8 49 in 215 6 mm L 6 2 in 157 7 mm between...

Страница 18: ...17K964 17K664 For model 17K965 17K663 For model 17E230 17K671 For model 17E232 17K667 For model 17E233 17K662 For model 17E234 17K670 For model 17E236 17K666 For model 17E237 17K661 For model 17E238 1...

Страница 19: ...st in manual 308048 1 2 17K659 LOWER 4 Ball see detailed parts list in manual 333022 1 3 16H434 TIE ROD 10 80 in 274 3 mm 8 37 in 212 6 mm between shoulders 3 4 108683 NUT lock hex 3 5 17F000 NUT coup...

Страница 20: ...4 Ball see detailed parts list in manual 3A3452 1 17K662 For model 17E234 17K670 For model 17E236 17K666 For model 17E237 17K663 For model 17E242 17K671 For model 17E244 17K667 For model 17E245 3 15G9...

Страница 21: ...COUNT 1 1000cc Open 49 0 1244 28 3 719 75 34 17E239 VISCOUNT 1 1000cc Sealed 51 9 1319 31 2 793 103 47 17E240 VISCOUNT 1 1000cc Open 49 0 1244 28 3 719 75 34 17E241 VISCOUNT 1 1000cc Open 49 0 1244 28...

Страница 22: ...43 in 188 mm 6 186 in 157 mm 4X 3 8 16 UNC 2B 6 186 in 157 mm Viscount II Motor Mounting Hole Layout Four 0 344 8 7 mm diameter holes 6 186 in 157 mm Four 0 45 11 4 mm diameter holes TI15860a TI10465a...

Страница 23: ...5 in 368 mm C 12 4 in 314 mm D 9 0 in 229 mm E 5 4 in 137 mm F 7 4 in 187 mm G 5 3 in 133 mm H 2 0 in 51 mm J 1 0 in 25 mm K 1 6 in 41 mm L 2 7 in 69 mm M 4 4 in 112 mm N Four 0 562 in 14 mm diameter...

Страница 24: ...es Follow right to scale to read hydraulic oil consumption See Models on page 3 for your pump part number Viscount I Plus Motor 750cc Lower Viscount I Plus Motor 1000cc Lower PUMP OUTLET PRESSURE PUMP...

Страница 25: ...5 6 160 1 12 11 2 40 0 28 2 8 120 0 84 8 4 GPM l min GPM l min Viscount I Plus Motor 1500cc Lower Viscount I Plus Motor 2000cc Lower 60 2 5 9 5 Key A 10 3 MPa 103 bar 1500 psi hydraulic pressure B 7 2...

Страница 26: ...B CYCLES PER MIN A C 450 3 1 31 350 2 4 24 250 1 7 17 150 1 0 10 50 0 3 3 0 4 8 12 16 20 24 28 32 36 16 0 60 6 18 0 68 1 HYDRAULIC OIL CONSUMPTIO N GPM l min 3 0 11 4 1 0 3 8 2 0 7 6 8 0 30 4 7 0 26...

Страница 27: ...Notes 3A3381E 27 Notes...

Страница 28: ...i 1 6 MPa 16 0 bar 17E230 17E231 17E232 17E233 167 psi 1 2 MPa 12 0 bar Max Hydraulic Working Pressure 1500 psi 10 3 MPa 103 0 bar Hydraulic Oil Consumption See Performance Charts in Manual See Perfor...

Страница 29: ...Pressure 17E242 17E243 17E244 17E245 460 psi 3 2 MPa 32 0 bar Max Hydraulic Working Pressure 1200 psi 8 3 MPa 83 bar Hydraulic Oil Consumption See Performance Charts in Manual See Performance Charts...

Страница 30: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...

Отзывы: