background image

Warnings 

3A3381E

5

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system com-
ponent. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all 
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information 
about your material, request Safety Data Sheet (SDS) from distributor or retailer.

Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create 
safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, 
follow the Pressure Relief Procedure and disconnect all power sources.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 
swallowed.

Read Safety Data Sheet (SDS) to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 
eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not 
limited to:

Protective eyewear, and hearing protection. 

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

Содержание Viscount 17E230

Страница 1: ...similar fluids For professional use only See page 3 for model information including maximum working pressure Important Safety Instructions Read all warnings and instructions in this manual Save these...

Страница 2: ...00cc or 2000cc with Sealed 4 Ball Lower 17 Viscount I Pumps Models 17K964 17K965 17E230 17E232 17E233 17E234 17E236 17E237 17E238 17E240 and 17E241 750cc 1000cc 1500cc or 2000cc with 4 Ball Lower Open...

Страница 3: ...ralife 17E234 VISCOUNT 1 1500cc Open 225 1 6 16 0 npt CS Chrome Chrome 17E235 VISCOUNT 1 1500cc Sealed 225 1 6 16 0 tri clamp SST Ultralife Ultralife 17E236 VISCOUNT 1 1500cc Open 225 1 6 16 0 npt SST...

Страница 4: ...ential static sparking Ground all equipment in the work area See Grounding instructions Never spray or flush solvent at high pressure Keep work area free of debris including solvent rags and gasoline...

Страница 5: ...ute hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Compl...

Страница 6: ...nk use a ground wire and clamp Dispense valve ground through a connection to a properly grounded fluid hose and pump Fluid supply container follow local code Object being sprayed follow local code Sol...

Страница 7: ...ring that there is sufficient clearance for fluid connections and for servicing the lower 4 Drill four 7 16 in 11 mm holes using the bracket as a template Use any of the three mounting hole groupings...

Страница 8: ...ulic Return Line For Viscount I Plus motors the hydraulic outlet on the motor is 7 8 in 22 mm 37 flare Use a mini mum 5 8 in 16 mm ID hydraulic return line K For Viscount II motors use a minimum 7 8 i...

Страница 9: ...Surge Tank J 10 Micron Return Filter K Hydraulic Return Line L Hydraulic Supply Line M Drain Line N Pressure Reducing Valve P Hydraulic Pressure Gauge R Return Line Shutoff Valve S Supply Line Shutof...

Страница 10: ...G Surge Tank J 10 Micron Return Filter K Hydraulic Return Line L Hydraulic Supply Line M Drain Line N Pressure Reducing Valve P Hydraulic Pressure Gauge R Return Line Shutoff Valve S Supply Line Shuto...

Страница 11: ...shutoff valve D downstream of the pump The pump should stall against pressure NOTE In a circulation system the pump operates con tinuously until the power supply is shut off In a direct supply system...

Страница 12: ...on reservoir and filter cleaning and periodic changes of hydraulic fluid Stall Test Perform a stall test periodically to ensure the piston seal is in good working condition and prevent system pres su...

Страница 13: ...o output Improperly installed ball check valves Check and repair Pump operates erratically Exhausted fluid supply Refill and re prime pump Held open or worn ball check valves Check and repair Worn pis...

Страница 14: ...ng the drain bottle to the tie rod 3 Loosen the coupling nut 5 and remove the collars 6 Remove the coupling nut from the piston rod R Unscrew the lock nuts 4 from the tie rods 3 Separate the motor 1 a...

Страница 15: ...75 80 ft lb 102 109 N m f Continue to step 2 2 Assemble the coupling nut 5 over the piston rod R 3 Orient the lower 2 to the motor 1 Position the lower on the tie rods 3 4 If you are reusing lock nut...

Страница 16: ...75 N m Lubricate threads Torque to 75 80 ft lb 102 109 N m Torque to 15 17 ft lb 20 23 N m Fill cavity with grease 1 2 3 4 6 7 1 2 3 Models with Open Wet Cup Lowers Viscount II motor shown Models with...

Страница 17: ...l see detailed parts list in manual 333022 1 17K656 For model 17K963 17K659 For model 17E231 17K658 For model 17E235 17K657 For model 17E239 3 17C261 TIE ROD 8 49 in 215 6 mm L 6 2 in 157 7 mm between...

Страница 18: ...17K964 17K664 For model 17K965 17K663 For model 17E230 17K671 For model 17E232 17K667 For model 17E233 17K662 For model 17E234 17K670 For model 17E236 17K666 For model 17E237 17K661 For model 17E238 1...

Страница 19: ...st in manual 308048 1 2 17K659 LOWER 4 Ball see detailed parts list in manual 333022 1 3 16H434 TIE ROD 10 80 in 274 3 mm 8 37 in 212 6 mm between shoulders 3 4 108683 NUT lock hex 3 5 17F000 NUT coup...

Страница 20: ...4 Ball see detailed parts list in manual 3A3452 1 17K662 For model 17E234 17K670 For model 17E236 17K666 For model 17E237 17K663 For model 17E242 17K671 For model 17E244 17K667 For model 17E245 3 15G9...

Страница 21: ...COUNT 1 1000cc Open 49 0 1244 28 3 719 75 34 17E239 VISCOUNT 1 1000cc Sealed 51 9 1319 31 2 793 103 47 17E240 VISCOUNT 1 1000cc Open 49 0 1244 28 3 719 75 34 17E241 VISCOUNT 1 1000cc Open 49 0 1244 28...

Страница 22: ...43 in 188 mm 6 186 in 157 mm 4X 3 8 16 UNC 2B 6 186 in 157 mm Viscount II Motor Mounting Hole Layout Four 0 344 8 7 mm diameter holes 6 186 in 157 mm Four 0 45 11 4 mm diameter holes TI15860a TI10465a...

Страница 23: ...5 in 368 mm C 12 4 in 314 mm D 9 0 in 229 mm E 5 4 in 137 mm F 7 4 in 187 mm G 5 3 in 133 mm H 2 0 in 51 mm J 1 0 in 25 mm K 1 6 in 41 mm L 2 7 in 69 mm M 4 4 in 112 mm N Four 0 562 in 14 mm diameter...

Страница 24: ...es Follow right to scale to read hydraulic oil consumption See Models on page 3 for your pump part number Viscount I Plus Motor 750cc Lower Viscount I Plus Motor 1000cc Lower PUMP OUTLET PRESSURE PUMP...

Страница 25: ...5 6 160 1 12 11 2 40 0 28 2 8 120 0 84 8 4 GPM l min GPM l min Viscount I Plus Motor 1500cc Lower Viscount I Plus Motor 2000cc Lower 60 2 5 9 5 Key A 10 3 MPa 103 bar 1500 psi hydraulic pressure B 7 2...

Страница 26: ...B CYCLES PER MIN A C 450 3 1 31 350 2 4 24 250 1 7 17 150 1 0 10 50 0 3 3 0 4 8 12 16 20 24 28 32 36 16 0 60 6 18 0 68 1 HYDRAULIC OIL CONSUMPTIO N GPM l min 3 0 11 4 1 0 3 8 2 0 7 6 8 0 30 4 7 0 26...

Страница 27: ...Notes 3A3381E 27 Notes...

Страница 28: ...i 1 6 MPa 16 0 bar 17E230 17E231 17E232 17E233 167 psi 1 2 MPa 12 0 bar Max Hydraulic Working Pressure 1500 psi 10 3 MPa 103 0 bar Hydraulic Oil Consumption See Performance Charts in Manual See Perfor...

Страница 29: ...Pressure 17E242 17E243 17E244 17E245 460 psi 3 2 MPa 32 0 bar Max Hydraulic Working Pressure 1200 psi 8 3 MPa 83 bar Hydraulic Oil Consumption See Performance Charts in Manual See Performance Charts...

Страница 30: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...

Отзывы: