background image

Operation

308345T

9

Operation

Find the Proper Agitator Speed

NOTE: Attach ground wire before using agitator.

1.

Fill the fluid supply container to about 3–4 inches (75–
100 mm) above the agitator blade.

2.

Start the agitator, and gradually increase the speed by 
turning the needle valve (14) until a vortex begins to 
form in the paint.

3.

Reduce the speed slightly, then fill the fluid 
container. Use the lowest agitator speed needed for 
thorough agitation of the paint. Excessive agitator 
speed may cause the paint to foam.

Pressure Relief Procedure

1.

Close the bleed-type air shutoff valve (SV) to relieve 
pressure to the air motor. 

2.

Disconnect the air line. 

Maximum Siphon Flow Rate

The volume of fluid that can be siphoned through the 
agitator inlet is determined by the viscosity of the fluid.

The maximum flow rate is approximately 12 gpm (45 
lpm) with 100-centipoise fluid.

The maximum flow rate is approximately 1.2 gpm 
(4.5 lpm) with much heavier 1000-centipoise fluid.

To prevent pump cavitation, avoid flow rates higher than 
these. Check the fluid periodically for signs of cavitation.

Air Requirements

For continuous use, the 0.75 HP air motor typically 

requires 2.5 scfm (0.071 m

3

/min.) of air at 400 rpm or 

5.7 scfm (0.162 m

3

/min.) of air at 800 rpm.

Nitrogen Charge the Drum

Operate the Agitator

See F

IG

. 7.

The bearing nut (8) helps prevent excessive fluid flow 
between the siphon tube (4) and helix tube (7), but it is 
not intended to be a complete seal. Fluids can pass 
through the bearing nut into the gap between the two 
tubes. Before you change colors or coatings or store the 
agitator, clean the fluid tubes. See Clean the Fluid 
Tubes
, page 12
.

NOTE: Thoroughly agitate the fluid before you use the 
suction feature. Agitating maximizes fluid quality and 
helps avoid solids getting drawn into the siphon tube 
and clogging it. Order part number 236984, strainer inlet 

Moving parts, such as an impeller blade, can cut or 
amputate fingers. To reduce the risk of serious injury, 
always shut off the agitator and disconnect the air line 
before moving, checking, or repairing the agitator.

This equipment stays pressurized until pressure is 
manually relieved. To help prevent serious injury from 
splashing fluid and moving parts, follow the Pressure 
Relief Procedure before cleaning, checking, or 
servicing the equipment.

NOTICE

If you are using nitrogen to charge the drum, use a 
maximum of 0.25 psi (1.7 kPa, 0.02 bar). Such low 
pressure requires special regulation equipment. Use a 
passive, non-pressurized system when possible. 
Higher pressure could push fluid through the shaft seal 
(21) and into the top bearings (11), damaging them. 
See Parts, page 18.

Содержание Twistork Helix 308345T

Страница 1: ...re For use in closed head bung type 55 gallon drums 100 psi 0 7 MPa 7 bar Maximum Working Pressure See page 2 for model information Important Safety Instructions Read all warnings and instructions in...

Страница 2: ...the Air Motor 11 Prolong the Life of the Bearing Nut 11 Clean the Fluid Tubes 12 Agitator Blades 13 Lubricate the Air Motor Model 236629 Only 13 Clean the Air Intake Check Valve 13 Correct a Bad Sucti...

Страница 3: ...and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggeri...

Страница 4: ...y approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for...

Страница 5: ...ess Reversible Agitator Model 236760 The oil less reversible agitator operates the same as the standard agitator but it uses a non lubricated air supply and the helix rotation can be reversed NOTE Alt...

Страница 6: ...k of fire and explosion always maintain a minimum of 1 in 25 4 mm clearance between rotating agitator parts and container to prevent sparks from contact FIG 3 Typical Installation AM SV AL MT AR AF Th...

Страница 7: ...for Model 236629 only Downstream from the filter install an air line lubricator for automatic air motor lubrication Set the lubricator feed rate at 1 drop of oil per minute for high speed or continuo...

Страница 8: ...ight 4 Position the air motor so the air line C can be attached to the inlet D on the needle valve without obstructing any other system components 5 When using the agitator suction feature connect a s...

Страница 9: ...0 162 m3 min of air at 800 rpm Nitrogen Charge the Drum Operate the Agitator See FIG 7 The bearing nut 8 helps prevent excessive fluid flow between the siphon tube 4 and helix tube 7 but it is not in...

Страница 10: ...ow it to drain Order part number 189658 accessory handle so you can connect a lift hook to raise and lower the agitator or hang the agitator to store it Do not let fluid dry in the fluid tubes See Cle...

Страница 11: ...the bearing nut 8 and could destroy it the next time you start the agitator Flush the fluid section before you change colors or coatings or store the agitator Do not operate the agitator without flui...

Страница 12: ...can be cleaned by pulling a solvent soaked rag through them NOTE After you mix or pump catalyzed materials that could set up between the tubes without air always remove the siphon tube and clean both...

Страница 13: ...allows make up air to enter the closed drum as fluid is drawn out through the agitator outlet port See FIG 8 The air intake check valve should be inspected and cleaned every 2000 operating hours or wh...

Страница 14: ...in lbs 9 0 to 11 3 N m NOTE If Step 1 does not correct the problem continue with Steps 2 through 5 2 Replace the rings 22 Make sure the outer lips face up as shown in FIG 9 3 Insert the inlet tube 4...

Страница 15: ...agitator on its side on the drive belt housing so the inlet is lower than the outlet This orientation prevents fluid from running into the bearing and drive belt area b Pull up on the fluid outlet fi...

Страница 16: ...to 60 to 70 in lb 6 8 to 7 9 N m 1 2 Apply PTFE spray lubricant to inside lip of bearing nut before you install it Apply PTFE spray lubricant to siphon tube 4 inlet end and to top 6 in 150 mm of heli...

Страница 17: ...shing 14 Then remove the installation tool Wedge a screwdriver blade into the gap of the bushing 14 to spread the bushing while inserting tube 7 7 Torque the three hex head screws 14a oppositely and e...

Страница 18: ...ed Bend washer tab up to lock Apply PTFE spray lubricant to inside lip of bearing nut before you install it Torque oppositely and evenly to 80 to 100 in lbs 9 to 11 3 N m Torque oppositely and evenly...

Страница 19: ...20 x 3 16 in not a replacement part 1 13 112550 PULLEY large drive belt 1 14 112551 BUSHING QD taper lock includes items 14a 1 14a SCREW hex head 10 24 x 1 in not a replacement part 3 15 112552 BELT d...

Страница 20: ...8 6 in 123 4 cm 32 in 81 3 cm minimum 35 1 8 in 89 2 cm maximum 3 4 14 npt f fluid outlet 1 8 npt f air inlet 2 npt bung adapter NOTE The bung adapter adjusts the depth of the agitator to a minimum of...

Страница 21: ...2 gpm approximately 4 5 lpm Air consumption at 400 rpm 2 5 scfm 0 071 m3 min at 800 rpm 5 7 scfm 0 162 m3 min Noise dBa Maximum sound pressure 70 dBA at 400 to 800 rpm Tested to CAGI PNEUROP 1969 Mat...