background image

Operation 

10

308345T

kit, to help prevent thick sediment from being forced into 
the siphon inlet.

NOTE: If you install an air shutoff valve, the same 
agitator speed is set each time it is turned on without 
requiring repeated needle valve adjustments.

You can also use an air line quick-disconnect (F) as a 
shutoff. See F

IG

. 6. See Air Line Quick-Disconnect

page 7.

F

IG

. 7: Operate the Agitator

Shutdown Procedure

1.

To stop the agitator, close the needle valve (18), or 
disconnect the quick-disconnect (F), or close the air 
valve in the air supply line.

2.

Follow the Pressure Relief Procedure, page 9.

3.

If you remove the agitator from the drum, remove 
the bearing nut (8), and hang or tilt the agitator 
upright over a container to allow it to drain. Order 
part number 189658, accessory handle, so you can 
connect a lift hook to raise and lower the agitator or 
hang the agitator to store it.

Do not let fluid dry in the fluid tubes. See Clean the 
Fluid Tubes
, page 12.

NOTICE

Do not operate the agitator at a high speed for a long 
period of time. Excessive agitator speed can cause the 
fluid to foam and can cause vibration and increased 
wear on parts and damage to the drum bung. Only 
agitate the fluid fast enough to maintain even mixing. 
You can view fluid movement through the 0.75-in. port 
on the drum cover.

Model 236629 shown

18

F

7

8

4

NOTICE

Keep the agitator upright. Do not lay it on its side or 
upside down, because fluid might flow into the beltdrive 
area causing damage.

If you use the accessory agitator handle, make sure the 
agitator is loosened from the drum before you raise it 
with a lift. The handle will not support the weight of the 
drum.

Содержание Twistork Helix 308345T

Страница 1: ...re For use in closed head bung type 55 gallon drums 100 psi 0 7 MPa 7 bar Maximum Working Pressure See page 2 for model information Important Safety Instructions Read all warnings and instructions in...

Страница 2: ...the Air Motor 11 Prolong the Life of the Bearing Nut 11 Clean the Fluid Tubes 12 Agitator Blades 13 Lubricate the Air Motor Model 236629 Only 13 Clean the Air Intake Check Valve 13 Correct a Bad Sucti...

Страница 3: ...and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggeri...

Страница 4: ...y approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for...

Страница 5: ...ess Reversible Agitator Model 236760 The oil less reversible agitator operates the same as the standard agitator but it uses a non lubricated air supply and the helix rotation can be reversed NOTE Alt...

Страница 6: ...k of fire and explosion always maintain a minimum of 1 in 25 4 mm clearance between rotating agitator parts and container to prevent sparks from contact FIG 3 Typical Installation AM SV AL MT AR AF Th...

Страница 7: ...for Model 236629 only Downstream from the filter install an air line lubricator for automatic air motor lubrication Set the lubricator feed rate at 1 drop of oil per minute for high speed or continuo...

Страница 8: ...ight 4 Position the air motor so the air line C can be attached to the inlet D on the needle valve without obstructing any other system components 5 When using the agitator suction feature connect a s...

Страница 9: ...0 162 m3 min of air at 800 rpm Nitrogen Charge the Drum Operate the Agitator See FIG 7 The bearing nut 8 helps prevent excessive fluid flow between the siphon tube 4 and helix tube 7 but it is not in...

Страница 10: ...ow it to drain Order part number 189658 accessory handle so you can connect a lift hook to raise and lower the agitator or hang the agitator to store it Do not let fluid dry in the fluid tubes See Cle...

Страница 11: ...the bearing nut 8 and could destroy it the next time you start the agitator Flush the fluid section before you change colors or coatings or store the agitator Do not operate the agitator without flui...

Страница 12: ...can be cleaned by pulling a solvent soaked rag through them NOTE After you mix or pump catalyzed materials that could set up between the tubes without air always remove the siphon tube and clean both...

Страница 13: ...allows make up air to enter the closed drum as fluid is drawn out through the agitator outlet port See FIG 8 The air intake check valve should be inspected and cleaned every 2000 operating hours or wh...

Страница 14: ...in lbs 9 0 to 11 3 N m NOTE If Step 1 does not correct the problem continue with Steps 2 through 5 2 Replace the rings 22 Make sure the outer lips face up as shown in FIG 9 3 Insert the inlet tube 4...

Страница 15: ...agitator on its side on the drive belt housing so the inlet is lower than the outlet This orientation prevents fluid from running into the bearing and drive belt area b Pull up on the fluid outlet fi...

Страница 16: ...to 60 to 70 in lb 6 8 to 7 9 N m 1 2 Apply PTFE spray lubricant to inside lip of bearing nut before you install it Apply PTFE spray lubricant to siphon tube 4 inlet end and to top 6 in 150 mm of heli...

Страница 17: ...shing 14 Then remove the installation tool Wedge a screwdriver blade into the gap of the bushing 14 to spread the bushing while inserting tube 7 7 Torque the three hex head screws 14a oppositely and e...

Страница 18: ...ed Bend washer tab up to lock Apply PTFE spray lubricant to inside lip of bearing nut before you install it Torque oppositely and evenly to 80 to 100 in lbs 9 to 11 3 N m Torque oppositely and evenly...

Страница 19: ...20 x 3 16 in not a replacement part 1 13 112550 PULLEY large drive belt 1 14 112551 BUSHING QD taper lock includes items 14a 1 14a SCREW hex head 10 24 x 1 in not a replacement part 3 15 112552 BELT d...

Страница 20: ...8 6 in 123 4 cm 32 in 81 3 cm minimum 35 1 8 in 89 2 cm maximum 3 4 14 npt f fluid outlet 1 8 npt f air inlet 2 npt bung adapter NOTE The bung adapter adjusts the depth of the agitator to a minimum of...

Страница 21: ...2 gpm approximately 4 5 lpm Air consumption at 400 rpm 2 5 scfm 0 071 m3 min at 800 rpm 5 7 scfm 0 162 m3 min Noise dBa Maximum sound pressure 70 dBA at 400 to 800 rpm Tested to CAGI PNEUROP 1969 Mat...

Страница 22: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...