Component Identification

308345T

5

Component Identification

The Twistork Helix Agitator is intended to mix and 
maintain paints and similar fluids in closed-head, 
55-gallon (200-liter) drums with 2 in. npt bung 
connections. The Twistork Helix Agitator provides 
suction porting through its siphon tube, which allows you 
to siphon fluid to a pump while mixing it.

Standard Agitator, Model 236629

The standard agitator operates in a center-lift fluid 
rotation mode, which is preferred in most applications 
because it minimizes fluid aeration. The helix rotates 
counterclockwise and mixes fluid by lifting it up from the 
bottom of the drum. See F

IG

. 1.

Standard agitator Model 236629 cannot reverse its 
helix rotation.

F

IG

. 1: Model 236629: Standard (counterclockwise) 

Rotation

Oil-less Reversible Agitator, 
Model 236760

The oil-less reversible agitator operates the same as the 
standard agitator, but it uses a non-lubricated air supply, 
and the helix rotation can be reversed.

NOTE: Although the air motor can operate without oil, 
motor life is increased when lubrication is provided.

To reverse the helix rotation on reversible agitator Model 
236760, remove the air motor muffler (16a) and needle 
valve (18), and switch the ports they are installed into. 
See F

IG

. 2.

When the helix rotation is reversed, the agitator 
operates in a pull-down fluid rotation mode, which can 
be better for agitating fluids that are difficult to put into 
suspension. The helix rotates clockwise and mixes fluid 
by pulling it down from the surface. See F

IG

. 2.

With clockwise (pull-down fluid rotation), care must be 
used at high speeds to prevent cavitation, which could 
be caused by air being drawn down to the siphon inlet.

F

IG

. 2: Model 236760: Reversed (clockwise) Rotation

16a

18

18

16a

Содержание Twistork Helix 308345T

Страница 1: ...re For use in closed head bung type 55 gallon drums 100 psi 0 7 MPa 7 bar Maximum Working Pressure See page 2 for model information Important Safety Instructions Read all warnings and instructions in...

Страница 2: ...the Air Motor 11 Prolong the Life of the Bearing Nut 11 Clean the Fluid Tubes 12 Agitator Blades 13 Lubricate the Air Motor Model 236629 Only 13 Clean the Air Intake Check Valve 13 Correct a Bad Sucti...

Страница 3: ...and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggeri...

Страница 4: ...y approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for...

Страница 5: ...ess Reversible Agitator Model 236760 The oil less reversible agitator operates the same as the standard agitator but it uses a non lubricated air supply and the helix rotation can be reversed NOTE Alt...

Страница 6: ...k of fire and explosion always maintain a minimum of 1 in 25 4 mm clearance between rotating agitator parts and container to prevent sparks from contact FIG 3 Typical Installation AM SV AL MT AR AF Th...

Страница 7: ...for Model 236629 only Downstream from the filter install an air line lubricator for automatic air motor lubrication Set the lubricator feed rate at 1 drop of oil per minute for high speed or continuo...

Страница 8: ...ight 4 Position the air motor so the air line C can be attached to the inlet D on the needle valve without obstructing any other system components 5 When using the agitator suction feature connect a s...

Страница 9: ...0 162 m3 min of air at 800 rpm Nitrogen Charge the Drum Operate the Agitator See FIG 7 The bearing nut 8 helps prevent excessive fluid flow between the siphon tube 4 and helix tube 7 but it is not in...

Страница 10: ...ow it to drain Order part number 189658 accessory handle so you can connect a lift hook to raise and lower the agitator or hang the agitator to store it Do not let fluid dry in the fluid tubes See Cle...

Страница 11: ...the bearing nut 8 and could destroy it the next time you start the agitator Flush the fluid section before you change colors or coatings or store the agitator Do not operate the agitator without flui...

Страница 12: ...can be cleaned by pulling a solvent soaked rag through them NOTE After you mix or pump catalyzed materials that could set up between the tubes without air always remove the siphon tube and clean both...

Страница 13: ...allows make up air to enter the closed drum as fluid is drawn out through the agitator outlet port See FIG 8 The air intake check valve should be inspected and cleaned every 2000 operating hours or wh...

Страница 14: ...in lbs 9 0 to 11 3 N m NOTE If Step 1 does not correct the problem continue with Steps 2 through 5 2 Replace the rings 22 Make sure the outer lips face up as shown in FIG 9 3 Insert the inlet tube 4...

Страница 15: ...agitator on its side on the drive belt housing so the inlet is lower than the outlet This orientation prevents fluid from running into the bearing and drive belt area b Pull up on the fluid outlet fi...

Страница 16: ...to 60 to 70 in lb 6 8 to 7 9 N m 1 2 Apply PTFE spray lubricant to inside lip of bearing nut before you install it Apply PTFE spray lubricant to siphon tube 4 inlet end and to top 6 in 150 mm of heli...

Страница 17: ...shing 14 Then remove the installation tool Wedge a screwdriver blade into the gap of the bushing 14 to spread the bushing while inserting tube 7 7 Torque the three hex head screws 14a oppositely and e...

Страница 18: ...ed Bend washer tab up to lock Apply PTFE spray lubricant to inside lip of bearing nut before you install it Torque oppositely and evenly to 80 to 100 in lbs 9 to 11 3 N m Torque oppositely and evenly...

Страница 19: ...20 x 3 16 in not a replacement part 1 13 112550 PULLEY large drive belt 1 14 112551 BUSHING QD taper lock includes items 14a 1 14a SCREW hex head 10 24 x 1 in not a replacement part 3 15 112552 BELT d...

Страница 20: ...8 6 in 123 4 cm 32 in 81 3 cm minimum 35 1 8 in 89 2 cm maximum 3 4 14 npt f fluid outlet 1 8 npt f air inlet 2 npt bung adapter NOTE The bung adapter adjusts the depth of the agitator to a minimum of...

Страница 21: ...2 gpm approximately 4 5 lpm Air consumption at 400 rpm 2 5 scfm 0 071 m3 min at 800 rpm 5 7 scfm 0 162 m3 min Noise dBa Maximum sound pressure 70 dBA at 400 to 800 rpm Tested to CAGI PNEUROP 1969 Mat...

Страница 22: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...

Отзывы: