Installation
308345T
7
F
IG
. 5: Install Flexible Suction Hose
Air Line Accessories
A bleed-type air shutoff valve (SV) is required; it isolates
the air line components for servicing. The air shutoff
valve should be installed in the supply line and can be
used to stop and start the agitator. If the valve is used to
stop and start the agitator, you do not need to set the
agitator speed each time it is used.
Order air shutoff valves by the part numbers listed
below:
110223 1/4”
npt(f)
x
1/4”
npt(f)
110224 3/8”
npt(f)
x
3/8”
npt(f)
113333 3/8”
npt(m) x
3/8”
npt(f)
The following air line accessories help to increase motor
life and ease of operation.
Air Line Filter
Air line filters remove harmful dirt and moisture from the
air supply. Order one of the following:
106148
3/8 npt(f) air line filter
106149
1/2 npt(f) air line filter
Air Line Lubricator (for Model 236629 only)
Downstream from the filter, install an air line lubricator
for automatic air motor lubrication. Set the lubricator
feed rate at 1 drop of oil per minute for high speed or
continuous duty usage. Do not overfeed oil or exhaust
air may become contaminated. To manually lubricate
the air motor, see Lubricate the Air Motor
(Model 236629 Only), page 13. Order one of the
following:
214847
3/8 npt(f) air line lubricator
214848
1/2 npt(f) air line lubricator
Air Line Quick-Disconnect
Install an air line quick-disconnect (F) or bleed-type air
shutoff valve at the air inlet (D). See F
. 6. Order one of
the following:
169969
1/8 npt(m) air line quick-disconnect
208536
1/4 npt(f) air line quick-disconnect
NOTICE
To avoid damaging the agitator, do not mount the pump
(G) directly to the agitator outlet fitting (41). Make sure
the pump is properly supported, and install a flexible
suction hose (E) between the agitator outlet fitting and
the pump, as shown in F
G
E
41
NOTICE
Not lubricating the air motor will cause air motor failure.