Grounding
WARNING
FIRE, EXPLOSION, AND ELECTRIC
SHOCK HAZARD
To reduce the risk of fire, explosion, or
electric shock:
D
The power source conduit is not an ad-
equate ground for the system. The unit
must be grounded to either the building
ground or a true earth ground.
D
A qualified electrician must complete
all grounding and wiring connections
and check the resistance.
D
Refer to your local code for the requirements for
a “true earth ground” in your area.
D
Also read and follow the warnings on page 5.
Ground the automatic dispense valve:
1.
Connect the connector from a heated hose to the
receptacle on the dispense valve.
Fig. 6
Ground lead
coming from pin
E is fastened to
the bracket.
A
E
B
F
C
D
Fig. 7
Ground lead
coming from con-
tact 8 to true
earth ground.
TI0305
6
7
5
4
1
2
3
2.
Connect the electrical cable to the electrical control
panel.
3.
Verify that socket contact E on six pin models (see
Fig. 5) or contact eight on eight pin models (see
Fig. 7) , inside control panel receptacle, is con-
nected to true earth ground.