6 310538
Installation
Install the automatic applicator as follows:
D
mount the automatic dispense valve
D
attach dispense tip, nozzle, or swirl
D
connect the air lines
D
connect material hose
D
connect the electrical cable
D
make sure the automatic dispense valve is
grounded
Mount the Automatic Dispense Valve
Mount the automatic dispense valve to the mounting
bracket on a stationary support or robotic arm (Fig. 1),
using two socket head screws (300) and two flat
washers (50). Be sure to position the insulation
block (280) and insulation tape (290) between the
dispense valve and the mounting bracket.
Fig. 1
A
50
300
280
290
Attach Dispense Tip, Nozzle, or Swirl
Attach a dispense tip and a nozzle adapter, or a nozzle
adapter alone, to the automatic dispense valve.
Dispense Tip and Nozzle Adapter Attachment
Attach dispense tip (B) to the automatic dispense
valve.
1.
Select a nozzle adapter (C) and a dispensing
tip (B).
2.
Install the tip and then use the nozzle adapter (C)
to secure the tip to the seat adapter (D).
Fig. 2
B
C
D