Electro-pneumatic Control Panel Display Screens
Material
Material
Material Recipe
Recipe
Recipe Timers
Timers
Timers Screen
Screen
Screen
Icon/Field
Icon/Field
Icon/Field
Description
Description
Description
Copy
Copy
Copy From...
From...
From...
Press to complete the fields of this recipe with the values assigned to
another recipe. The copied values will overwrite any defined values in this
recipe. After copying, individual fields can be modified to differentiate this
recipe from the one copied.
NOTE:
NOTE:
NOTE: Copying a locked recipe will also copy the password and save the
new recipe as a locked recipe.
Prime
Prime
Prime Time
Time
Time
Length of time, in seconds, to attempt to achieve a prime of the pump with
the product in the tote. The pump will operate at the slow speed until the
amount of time specified by this field has elapsed. The pump will then
operate at the fast speed.
Empty
Empty
Empty Time
Time
Time
When the ram assembly reaches the empty position, the pump will then
operate for the amount of time entered in this field. Once this time has
elapsed, the pump will stop or raise if Auto Raise is checked.
Seal
Seal
Seal Deflate
Deflate
Deflate Time
Time
Time
Length of time, in seconds, to deflate the ram plate seal.
Air
Air
Air Assist
Assist
Assist Time
Time
Time
Length of time, in seconds, to apply blowoff air.
Save
Save
Save
Save the current values displayed. If this screen is exited without saving,
any changes made to the screen are lost.
Back
Back
Back
Return to the recipe list screen. If this screen is exited without saving, any
changes made to the screen are lost.
44