Setup
3A6884B
13
Connect Hose and Tool
The TSP power pack uses flush-face
quick-release couplings that are durable and
easy to clean. To connect hose and tool,
follow the steps below.
1.
Wipe the mating surfaces of the
couplings on the TSP power pack and
the hoses with a clean rag before making
connection.
2.
Connect the hoses from the TSP power
pack to the hydraulic tool.
NOTE:
When making connections, do not
over stretch the hoses or bend hoses at a
sharp angle.
Hose Prime Procedure
Prime and flush the hoses each time a hose
is replaced or when swapping tools.
Continuous use of a hose and tool
combination should not require a prime and
flush procedure unless the hoses lose oil.
1.
Turn ON/OFF switch to
OFF
position.
2.
Connect hoses to the manifold on the
TSP power pack.
3.
Connect hoses together at tool end of
the hose.
4.
Turn ON/OFF switch to
ON
position.
5.
Set pressure control to minimum
pressure.
6.
Run the TSP power pack for 30 seconds
to purge the air from the hoses.
7.
Check hydraulic oil level. Fluid level
should be at the top of the oil level sight
glass. Add oil as needed.