Setup
12
3A6884B
Modes
The TSP power pack has three modes:
prime
,
calibration
, and
operation
.
The
prime
mode removes air from the pump.
The
calibration
mode calibrates the
pressure sensor. See
The
operation
mode is the normal mode in
which the TSP power pack is ready to torque
bolts.
Prime TSP Power Pack
Procedure
Priming is required after initial oil fill or pump
replacement. Unit may also require priming
when displayed control pressure reading
fluctuates continuously.
1.
Disconnect hoses, if attached.
2.
Plug in TSP power pack.
3.
Turn ON/OFF switch to
ON
position
.
4.
Turn Pressure Setting Valve
counterclockwise until rotation stops.
This is the zero pressure setting.
5.
Cycle through primary menu by short
pressing the control Display Button until
PRIME
appears on Display.
6.
Press the Advance Switch on selected
control device to start prime mode.
90
will appear on the Display and will count
down in seconds as the prime procedure
automatically occurs.
NOTE:
Press Display Button or Pump Stop
Switch any time while in prime mode to
cancel the procedure.
NOTE:
TSP power pack will automatically
return to operation mode when prime
procedure is complete.
7.
To ensure the TSP power pack is
primed, set pressure to 8000 psi and
press the Advance Switch on selected
control device. The Display pressure
reading should be steady at 8000 +/- 50
psi. If pressure fluctuations are 100 psi or
greater, the
should be repeated.
8.
Inspect for leaks. If leaking occurs,
tighten all fittings and repeat the
9.
Check hydraulic fluid level.
High-pressure leaks are able to inject oil
into the body and cause serious bodily
injury. Do not stop leaks with hand or rag.