25
63*
*72
67
74*
75*
76*
73*
PART OF
ITEM 67
77
22
5
B
B
J
41
*70
40
82
83
81
38
41
80
REF)
41
23
C
C
40
79
78
*71
*73
(REF)
19*
J
7
82
80
40
40
Fig. 5
1
Arrow on body must point away from pump.
1
0974C
9
307929
Installation
5.
Screw the check valve (70*) into the pump’s fluid
outlet, making certain that the arrow on the check
valve points away from the pump. Screw the rigid
end of the adapter (71*) onto the check valve. See
Fig. 5.
6.
Install the 3/8 npt nipple (63*) in the heater outlet.
Screw the male end of the 90
swivel (19*) into the
inlet of the fluid filter (25). Screw the female end of
the swivel (19*) onto the nipple (63*) at the heater
outlet, and tighten securely.
7.
Screw the elbow (72*) into the heater’s inlet.
Attach the 1/2” x 3’ (0.9 m) hose (73*) to the
elbow. Attach the other end of the hose to the
swivel of the adapter (71*) at the pump outlet.