11
307929
Installation
Converting to a Two-Gun System
To convert your sprayer to a two-gun system, refer to
the following applicable paragraph for your model
(refer to page 12 for Models 231162, 224629 and
231161). Order the parts listed, and perform the as-
sembly procedure.
Model 231158 (Refer to Figs. 6 and 7, and the Parts
Drawing on page 16)
WARNING
Before performing this procedure, follow the
Pres-
sure Relief Procedure
on page 14. Disconnect all
hoses from the pump.
NOTE:
Model 231158 includes a hose and gun set, so
you should order only one additional gun, air hose and
fluid hose.
Part No.
Description
Qty
156877
NIPPLE; 1/2 npt; 2.5” long
2
158683
ELBOW, 90
; 1/2 npt (m x f)
2
103475
TEE; 1/2 npt(f) run;
1/2 npt(f) branch
1
104267
AIR REGULATOR
1
101180
GAUGE, pressure, air
1
100509
PLUG, pipe; 1/4 npt
1
166999
ELBOW, street, reducing;
1/2 npt(m) x 1/4 npt(f)
1
162453
NIPPLE; 1/4 npt x 1/4 npsm
2
100840
ELBOW, street, 90
;
1/4 npt (m x f)
1
238852
GUN, spray, air-assisted airless
2
216069
HOSE, air; nylon; 1/4” ID;
cpld 1/4 npsm (fbe) swivel;
26 ft (7.9 m) long
2
214698
HOSE, fluid; nylon; 3/16” ID;
cpld 1/4 npsm(f) swivel x
1/4 npt(m); 25 ft (7.6 m) long
2
1.
Remove the gun air regulator (31) from the nipple
(30) coming off the air manifold (29). Do not re-
move any parts from the regulator. Save the
regulator for use in step 4. See Fig. 6.
2.
Install a 101180 Gauge (P) and 100509 Plug (Q)
on a 104267 Air Regulator (R). Screw a 166999
Elbow (S) into the outlet port of this air regulator,
and screw a 162453 Nipple (T) into the elbow.
3.
Screw the branch of the 103475 Tee (L) onto the
nipple (30) at the air manifold (29). Install a
156877 Nipple (M) in each open port of the tee.
Screw a 158683 Elbow (N) onto each nipple.
4.
Install the air regulator removed in step 1 onto one
of the elbows (N). This is the air control for the first
gun. Install the air regulator assembled in step 2
onto the other elbow (N), so both regulators are
facing the same way. This is the air control for the
second gun.
5.
Remove the plug (27) from the optional outlet port
of the fluid filter (25). Install a 100840 Elbow (V)
and 162453 Nipple (T) in its place. See Detail A of
Fig. 7. This is the fluid connection for the second
gun.
6.
Connect the fluid and air hoses to the guns as
explained on page 6 (see Detail D of Fig. 7).
Содержание Ratio Monark Hydra-Spray Series