background image

2

307929

Table of Contents

Warnings

2–4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Installation

5–13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Operation

14–15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Parts Drawings and Lists

16–21

. . . . . . . . . . . . . . . . . . . 

Conversion Kits

23

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Technical Data

23

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Warranty

24

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Graco Information

24

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Symbols

Warning Symbol

WARNING

This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.

Caution Symbol

CAUTION

This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
corresponding instructions.

WARNING

INSTRUCTIONS

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

This equipment is for professional use only.

Read all instruction manuals, tags, and labels before operating the equipment.

Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco
distributor.

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not exceed the maximum working pressure of the lowest rated system component. Refer to the

Technical Data

 on page 23 for the maximum working pressure of this equipment.

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the 

Tech-

nical Data

 section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

Do not exceed the maximum working pressure of the lowest rated system component. This equip-
ment has a 

950 psi (6.6 MPa, 66 bar) maximum working pressure.

Do not use hoses to pull equipment.

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose
Graco hoses to temperatures above 82

C (180

F) or below –40

C (–40

F).

Wear hearing protection when operating this equipment.

Do not lift pressurized equipment.

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

Содержание Ratio Monark Hydra-Spray Series

Страница 1: ...ations Includes pump cart hose gun and tip Model 231162 Series B For cold spray applications Includes pump cart fluid regulation kit 222564 hose gun and tip Model 224629 Series A For heated spray appl...

Страница 2: ...r Do not alter or modify this equipment Use only genuine Graco parts and accessories Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum working pressur...

Страница 3: ...gun trigger safety operates before spraying Lock the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 14 whenever you are instructed to relieve pres sure stop sp...

Страница 4: ...e of debris including solvent rags and gasoline Electrically disconnect all equipment in the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do n...

Страница 5: ...in the spray area Check your local electrical code for detailed grounding instructions for your area and type of equipment Be sure to ground all of this spray equipment 1 Pump loosen the grounding lug...

Страница 6: ...cycle unexpectedly To bleed air from the pump the pump air regulator must be open when you close this valve The air relief valve 52 opens automatically to relieve air pressure to the pump if the the p...

Страница 7: ...nnect the fluid regulator and bracket to the side of the cart 7 using the screw 66l lockwasher 66m and nut 66n Connect the 22 560 mm hose 66h to the outlet of the fluid filter 25 Connect the gun air s...

Страница 8: ...all male threads except at swiveling connections 1 Remove the cover from the electrical box H at the back of the heater 67 Screw the bushing 74 into the inlet of the electrical box Install the cord g...

Страница 9: ...ck valve points away from the pump Screw the rigid end of the adapter 71 onto the check valve See Fig 5 6 Install the 3 8 npt nipple 63 in the heater outlet Screw the male end of the 90 swivel 19 into...

Страница 10: ...support bracket 4 Screw one of the nipples 41 into the outlet in the base of the back pressure regulator 83 then screw one of the elbows 40 onto the nipple so the male end of the elbow faces forward I...

Страница 11: ...ivel 26 ft 7 9 m long 2 214698 HOSE fluid nylon 3 16 ID cpld 1 4 npsm f swivel x 1 4 npt m 25 ft 7 6 m long 2 1 Remove the gun air regulator 31 from the nipple 30 coming off the air manifold 29 Do not...

Страница 12: ...e 14 Disconnect all hoses from the pump NOTE For Model 224629 order two 238852 Guns and two 222264 Hose Kits Model 231161 includes a gun and a hose kit so you should order only one additional gun and...

Страница 13: ...els 224629 231161 Only V 40 25 66f 66a 66b 66b 66j 66e 66c 66d U T 83 T V 80 41 40 41 DETAIL D Assembly of Hoses and Gun Models 231158 and 231162 Only DETAIL E Assembly of Hose Kit and Gun Models 2246...

Страница 14: ...warnings cautions and instructions in this manual and all manuals supplied with each compo nent or accessory Flush the Pump Before Using Pumps are tested with lightweight oil which is left in to prote...

Страница 15: ...mp and lines with fluid being sure to eliminate all air from the fluid sys tem or flush the pump as described in Shutdown and Care at right Heated Systems Operating instructions for a heated circulati...

Страница 16: ...16 307929 Parts 0979B Model 231158 1 3 4 5 7 21 22 23 20 25 27 27 29 30 31 32 33 33 REF 34 38 41 41 52 57 60 61 62 24 64 65 39 84 85 86 A A 7 REF See Detail Above For Parts 26 40 6...

Страница 17: ...range See 308167 for parts 2 32 161037 UNION adapter 90 1 2 npt m x 3 8 npsm f swivel 1 33 204560 HOSE air buna N 3 8 ID cpld 3 8 npt mbe 18 457 mm long 1 34 101180 GAUGE pressure air 0 200 psi 0 14 b...

Страница 18: ...25 27 27 29 30 31 32 33 33 REF 34 38 41 40 52 57 60 61 62 24 64 65 66a 66b 66c 66e 66d 66f 66h 66h REF Ref No 66 Fluid Regulation Kit includes items 66a 66q 39 A A B B 66j 66k 66l 66m 66n 66q 66p 66b...

Страница 19: ...not shown 1 52 103347 VALVE relief air 1 57 171987 TEE 3 8 npt x 1 4 npt run 3 8 npt branch 1 60 222297 UNION adapter 45 1 2 npt m x 1 2 npsm f swivel 1 61 158491 NIPPLE 1 2 npt 1 5 8 long 1 62 107142...

Страница 20: ...23 20 25 27 27 29 30 31 32 33 33 REF 34 38 41 41 52 57 60 61 62 64 65 39 84 86 A A B B 7 REF 38 78 77 79 80 REF 81 82 83 41 Part Of Item 67 87 88 89 90 91 92 Ref No 85 Hose Kit Includes Items 86 92 C...

Страница 21: ...4 150286 ADAPTER 3 8 npt m x f 1 65 210658 DRAIN VALVE 3 8 npt mbe See 306861 for parts 1 67 220522 VISCON HEATER 120V See 307805 for parts 1 70 206962 CHECK VALVE 3 8 npt mbe 1 71 159801 UNION adapte...

Страница 22: ...22 307929 Notes...

Страница 23: ...t pipe sealant 110110 Kit 222436 includes some parts not required for this pump 156953 Mounting Stud 100639 Lockwashers 100023 Washer 100307 Nut and 102814 Gauge Manual Change Summary This manual was...

Страница 24: ...y shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any oth...

Отзывы: