Service
6
3A8507C
Service
After the TLM has been installed, the only additional
maintenance or service necessary is changing the
batteries.
Replace Batteries
1. Remove the TLM adapter from the tank.
2. Remove the four screws that keep the case
together (F
. 7).
3. Carefully pull the TLM case halves apart to access
the battery (F
. 8).
NOTE: The TLM case halves are tightly connected. Use
caution when opening the device to prevent
unnecessary damage.
4. Replace the 3.6V C-size battery. See
, page 8, for battery information.
Install the battery as shown in F
. 9, with the
positive end on the right. This is the clip that has
shrink tubing on it.
5. To maintain the IP rating, make sure that the gasket
is properly installed (F
. 9).
6. Reconnect the two halves and replace the four
screws.
WARNING
Fire and Explosion Hazard
Sparking can occur when changing batteries. Only
replace the batteries in a non-hazardous location
away from flammable fluids and fumes.
NOTICE
After battery placement, press the button to synchronize
the TLM internal clock to maintain scheduled TLM
readings.
F
IG
. 7
Screws
F
IG
. 8
F
IG
. 9
Place Gasket
Here