background image

Technical Specifications 

8

3A8507C

Technical Specifications

California Proposition 65

Tank Level Monitor (TLM)

US

Metric

Compatible Fluids

oil, kerosene, diesel, lubricants, additives, DEF/AdBlue

®

, coolants, 

water, waste oil, waste water, automatic transmission fluid (AFT), 

anti-freeze, and windshield washer solution

Ultrasonic Tank Depth Measurement range

5.0 in. to 9 ft. 7 in.

12 cm (minimum) to 300 cm

Fluid Level Measurement Accuracy

+/- 1.0 in.

+/- 2.0 cm

Mounting

1.25 in., 1.5 in, and 2.0 in. threaded npt connector

Clearance: Height above tank for TLM

7.5 in.

19.1 cm

Weight

0.5 lb.

226.8 g

RF Frequency Band

2.412 GHz - 2.462 GHz

Maximum RF Transmit Power

18 dBm

Operating Temperature Range

0°F to 122°F

-17.8°C to 50°C

Storage Temperature Range

0°F to 122°F

-17.8°C to 50°C

Batteries

Li-SOCl2 Size R14, 3.6V C-cell

Battery Life

7.5 years* from activation

Enclosure (Ingress Protection)

IP67

Tanks

Maximum Volume

999,999 gallons

999,999 liters

Maximum Height

9 ft. 7 in.

300 cm

Altitude

<6,000 ft.

< 2 km

* The battery life is based upon four (4) measurements per day and one (1) WiFi connection per day from a location 

where the WiFi coverage does not require retries, and a normal distribution over the operating temperature range 

centered at +25°C (77°F).

All trademarks or registered trademarks are the property of their respective owners.

CALIFORNIA RESIDENTS

 WARNING:

 Cancer and reproductive harm – www.P65warnings.ca.gov.

Содержание Pulse 25T460

Страница 1: ...can cause death or serious injury Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for t...

Страница 2: ...k password 6 Click the Connect to WIFI button 7 The LED on the Pulse sensor turns green FIG 3 8 Wait approximately 20 seconds 9 The sensor flashes red or green several times Green flashes indicate tha...

Страница 3: ...ss steel self tapping counter sunk screws included with kit to attach the adapter to the tank Do not over tighten 4 Attach the sensor to the adapter To form a secure seal make sure that the sensor is...

Страница 4: ...ll 3 Continue with Mount Options steps 1 through 4 Operation View Data The TLM can be configured with the Pulse Level level gracopulse com to take a reading at predefined times After configuring the T...

Страница 5: ...gs Out of WiFi range WiFi obstruction Ensure that the TLM is not encased in metal since this would obstruct the signal Take a manual measurement and review LEDs during the measurement Weak or dead bat...

Страница 6: ...ize battery See Technical Specifications page 8 for battery information Install the battery as shown in FIG 9 with the positive end on the right This is the clip that has shrink tubing on it 5 To main...

Страница 7: ...llons or liters Tank end walls must be flat they cannot be any other shape including belled Obround Tank Maximum volume 999 999 gallons or liters Tank end walls must be flat they cannot be any other s...

Страница 8: ...2 GHz 2 462 GHz Maximum RF Transmit Power 18 dBm Operating Temperature Range 0 F to 122 F 17 8 C to 50 C Storage Temperature Range 0 F to 122 F 17 8 C to 50 C Batteries Li SOCl2 Size R14 3 6V C cell B...

Страница 9: ...MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other re...

Страница 10: ...hanges at any time without notice Original instructions This manual contains English MM 3A8507 Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRACO INC AND SUBSIDIARIES...

Отзывы: