Service
311189L
23
Replacing Control Board
1.
Follow
procedure, page 22.
2.
Loosen 6 screws (5) on bottom of panel to remove
control board cover (6). F
. 20 (RoboMix Fluid
Panel only.)
3.
Disconnect fiber optic wires and all cables (J1, J3,
J4, J5, J6, J9, J10) from control board (706). F
IG
.
21.
4.
Remove 4 screws (707). Remove control board
(706). F
IG
. 21. (RoboMix Fluid Panel not shown;
use same procedure.)
5.
Install new control board (706) with 4 screws (707).
6.
Connect cables to control board (706). F
IG
. 23.
Insert fiber optic cable connectors (J4, J6) into
board connectors (E), matching blue with blue,
black with black, and hand-tighten connectors (E).
F
IG
. 23 and F
IG
. 23.
7.
Reassemble control board cover with 6 screws (5).
F
. 20. (RoboMix Fluid Panel only.)
8.
9.
Turn EasyKey™ power on to test operation.
Replacing Solenoids
The Fluid Panel has a minimum of 4 solenoids. If you
have a color change valve option installed, you have
additional (optional) solenoids for each color dump valve
and dump valve and catalyst dump valve. Refer to
To replace a single solenoid.
CAUTION
To avoid damaging circuit board when servicing, wear
grounding strap on wrist and ground appropriately.
F
IG
. 20
F
IG
. 21
5
6
707
706
TI7223a
F
IG
. 22: RoboMix Fluid Panel Circuit Board
F
IG
. 23: Wall Mount Fluid Panel Circuit Board
E
E
Содержание ProMix Auto Series
Страница 31: ...Parts 311189L 31 TI6802B TI7281A See Detail below A B C D E F G H J K L M N P R S T Ref U Ref V W U T S Ref X...
Страница 33: ...Parts 311189L 33 TI6803b TI6809a See Detail below A B C D G H J K L M N P W U T R X...
Страница 35: ...Parts 311189L 35 TI7149a 21 20 19 24 23 9 9 2 6 29 10 11 12 5 15 27 28 26 14 29 17 1 3 4 25 38 8 7 37 34 31 35...
Страница 40: ...Parts 40 311189L Notes...
Страница 43: ...Parts 311189L 43 1 2 12 15 14 11 Alarm 4 9 14a 14c 14b 8 3 6 5 6 TI4530b 10 19 20 17 19 14d 14f 14e...
Страница 46: ...Parts 46 311189L Notes...