24
311189L
1.
procedure, page 22, and shut
off power at main circuit breaker.
2.
Disconnect 2 solenoid wires (N) from control board
(2). F
IG
. 24 and F
. 25 (wires not shown in F
25).
3.
Unscrew 2 screws (P) and remove the solenoid.
4.
Install new solenoid (9).
5.
Connect 2 wires (N) to control board (2). Solenoid
wires are polarized (red +, black –). Refer to
ProMix™ Auto Electrical Schematic
6.
Reassemble control board cover.
Reassemble Fluid Panel
1.
Slide the cover (3) back into place.
2.
Secure the cover (3) and panel with the 4 screws
(4). F
IG
. 26 and F
IG
. 19.
Solenoid
Actuates
Standard
1
Dispense Valve A
2
Dispense Valve B
3
Air Purge Valve A
4
Solvent Purge Valve B
Optional
5
Dump A Valve
6
Dump B Valve
7
Third Purge Valve (Wall Mount Fluid Panel
only.) See manual 311395.
F
IG
. 24: Wall Mount Fluid Panel Solenoids
V
2
4
N
P
9
6
5
4
3
2
1
TI7157a
F
IG
. 25: RoboMix Fluid Panel Solenoids
F
IG
. 26
1 2 3
4
9
P
3
4
2
T!7224a
Содержание ProMix Auto Series
Страница 31: ...Parts 311189L 31 TI6802B TI7281A See Detail below A B C D E F G H J K L M N P R S T Ref U Ref V W U T S Ref X...
Страница 33: ...Parts 311189L 33 TI6803b TI6809a See Detail below A B C D G H J K L M N P W U T R X...
Страница 35: ...Parts 311189L 35 TI7149a 21 20 19 24 23 9 9 2 6 29 10 11 12 5 15 27 28 26 14 29 17 1 3 4 25 38 8 7 37 34 31 35...
Страница 40: ...Parts 40 311189L Notes...
Страница 43: ...Parts 311189L 43 1 2 12 15 14 11 Alarm 4 9 14a 14c 14b 8 3 6 5 6 TI4530b 10 19 20 17 19 14d 14f 14e...
Страница 46: ...Parts 46 311189L Notes...