Technical Data
311189L
47
Technical Data
*
Dependent on programmed K-factor and application. The ProMix™ Auto maximum allowable flow meter pulse
frequency is 425 Hz (pulses/sec.). For more detailed information on viscosities, flow rates, or mixing ratios, con-
sult your Graco distributor.
See individual component manuals for additional technical data.
Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . see page 3
Maximum working air pressure . . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Air supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75–100 psi (0.5–0.7 MPa, 5.2–7 bar)
Air filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 micron (minimum) filtration required; clean and dry air
Mixing ratio range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1:1–30:1*
On-ratio accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to + 1%, user selectable
Fluids handled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . one or two component:
• solvent and waterborne paints
• polyurethanes
• epoxies
• acid catalyzed varnishes
• moisture sensitive isocyanates
Viscosity range of fluid . . . . . . . . . . . . . . . . . . . . . . . . . . . 20–5000 cps*
Fluid filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mesh minimum
Fluid flow rate range*
G3000, G250 Meter . . . . . . . . . . . . . . . . . . . . . . . . . .
G3000HR, G250HR Meter . . . . . . . . . . . . . . . . . . . . .
Coriolis Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
75–3000 cc/min. (0.02–0.79 gal./min.)
38–1500 cc/min. (0.01–0.40 gal./min.)
20–3800 cc/min. (0.005–1.00 gal./min.)
External Power Supply Requirements . . . . . . . . . . . . . . . 85–250 Vac, 50/60 Hz, 2 amps maximum draw
15 amp maximum circuit breaker required
8 to 14 AWG power supply wire gauge
Operating temperature range . . . . . . . . . . . . . . . . . . . . . . 41–122° F (5–50° C)
Environmental Conditions Rating . . . . . . . . . . . . . . . . . . . Indoor use, Pollution degree (2). Installation category II.
Noise Level
Sound pressure level . . . . . . . . . . . . . . . . . . . . . . . . .
Sound power level . . . . . . . . . . . . . . . . . . . . . . . . . . .
below 70 dBA
below 85 dBA
Wetted parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303, 304 SST, 17–4 SST, Tungsten carbide (with nickel
binder), perfluoroelastomer; PTFE; CV75
Weight
Base System Total (no meters color change valves) 66.6 lbs (30.2 kg)
EasyKey™ Display. . . . . . . . . . . . . . . . . . . . . . . . 22.2 lbs (10.1 kg)
Wall Mount Fluid Panel (no meters). . . . . . . . . . . 41.3 lbs (18.7 kg)
RoboMix II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26.5 lbs (12.0 kg)
Flow Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.0 lbs (1.8 kg)
Optional Components
G3000, G3000HR Flow Meter . . . . . . . . . . . . . . . 6 lbs. (2.7 kg) each
G250, G250HR Flow Meter . . . . . . . . . . . . . . . . . 4.5 lbs (2.0 kg) each
Coriolis Flow Meter . . . . . . . . . . . . . . . . . . . . . . . 33 lbs. (15 kg) each
Low Pressure Color Change Stack (6 color) . . . . 3.0 lbs (1.4 kg)
High Pressure Color Change Stack (6 color). . . . 11.0 lbs (5.0 kg)
Содержание ProMix Auto Series
Страница 31: ...Parts 311189L 31 TI6802B TI7281A See Detail below A B C D E F G H J K L M N P R S T Ref U Ref V W U T S Ref X...
Страница 33: ...Parts 311189L 33 TI6803b TI6809a See Detail below A B C D G H J K L M N P W U T R X...
Страница 35: ...Parts 311189L 35 TI7149a 21 20 19 24 23 9 9 2 6 29 10 11 12 5 15 27 28 26 14 29 17 1 3 4 25 38 8 7 37 34 31 35...
Страница 40: ...Parts 40 311189L Notes...
Страница 43: ...Parts 311189L 43 1 2 12 15 14 11 Alarm 4 9 14a 14c 14b 8 3 6 5 6 TI4530b 10 19 20 17 19 14d 14f 14e...
Страница 46: ...Parts 46 311189L Notes...