![Graco ProMix Auto Series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/graco/promix-auto-series/promix-auto-series_service-parts_2253522003.webp)
ProMix
™
Auto Models
311189L
3
ProMix
™
Auto Models
Do not install equipment approved only for a non-haz-
ardous location in a hazardous area. Substitution of
components may impair intrinsic safety. See page 5.
Changing the fluid manifold configuration may change
its pressure rating. Do not exceed the pressure rating
of the lowest rated component. See page 5.
Enter Model number here
(See “ProMix Auto Smart Part Numbers” on page 4)
ProMix™ Auto
™
Unit
A & B Meters
Color Options
Catalyst
Flow Control
Hazardous Location Approval
O
nly models with a G3000, G250 or G3000HR, G250HR for both
A and B meters are approved for installation in a Hazardous
Location - Class I, Div I, Group D, T3.
Non-hazardous Location Approval
Maximum Working Pressure
Maximum working pressure rating is dependent on the A and B meter and color change option selected. The pres-
sure rating is based on the rating of the lowest rated fluid manifold component. Refer to the component pressure
ratings below.
Example:
Model WP 1640 has a maximum working pressure of 3000 psi (21 MPa, 207 bar).
Check the ID plate on your EasyKey Display or fluid panel for its maximum working pressure. See F
page 7.
ProMix™ Auto Fluid Manifold Components Maximum Working Pressure
Wall Mount Fluid Panel Options:
Color Change Option 1, 2, 3 and 4...... 300 psi (2.1 MPa, 21 bar)
Color Change Option 5, 6, 7, and 8...... 3000 psi (21 MPa, 207 bar)
Coriolis A and B Meters Option....... 2300 psi (16 MPa, 159 bar)
No Meters or G3000, G3000HR...... 4000 psi (27.6 MPa, 276 bar)
Wall Mount Modules with Flow Control....... 200 psi (1.4 MPa 138 bar)
RoboMix II Panel Options (all).....190 psi (1.3 MPa, 131 bar)
Flow Meter Fluid Flow Rate Range
G3000, G250 Meter 75-3000 cc/min. (0.02-0.79 gal./min.)
G3000HR, G250HR Meter 38-1500 cc/min. (0.01-0.40 gal./min.)
Coriolis Meter 20-3800 cc/min. (0.005-1.00 gal./min.)
Conforms to
FM std 3600 & 3610
for use in Class I Div 1
Group D
T2 C Hazardous locations
[Ex ia] / x ia
CAN/CSA
22.2 No. 157-92
No. 1010.1-92
C
US
II 2 G
EEx ib IIA T3
ISSeP 06 ATEX 014
Содержание ProMix Auto Series
Страница 31: ...Parts 311189L 31 TI6802B TI7281A See Detail below A B C D E F G H J K L M N P R S T Ref U Ref V W U T S Ref X...
Страница 33: ...Parts 311189L 33 TI6803b TI6809a See Detail below A B C D G H J K L M N P W U T R X...
Страница 35: ...Parts 311189L 35 TI7149a 21 20 19 24 23 9 9 2 6 29 10 11 12 5 15 27 28 26 14 29 17 1 3 4 25 38 8 7 37 34 31 35...
Страница 40: ...Parts 40 311189L Notes...
Страница 43: ...Parts 311189L 43 1 2 12 15 14 11 Alarm 4 9 14a 14c 14b 8 3 6 5 6 TI4530b 10 19 20 17 19 14d 14f 14e...
Страница 46: ...Parts 46 311189L Notes...