background image

Warnings 

2

312417F

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back 
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where 
applicable.

WARNING

ELECTRIC SHOCK HAZARD 

Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing 
equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local codes and 
regulations.

FIRE AND EXPLOSION HAZARD 

When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be 
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources, such as cigarettes and portable electric lamps. 

Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.

Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

Ground all equipment in the work area.

Use only grounded hoses.

If there is static sparking or you feel a shock, 

stop operation immediately.

 Do not use equipment 

until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

EQUIPMENT MISUSE HAZARD 

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. See 

Technical Data

 in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical Data 

in all

 

equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information 
about your material, request MSDS forms from distributor or retailer.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

Содержание Matrix PAC 247436

Страница 1: ...Pa 1 7 bar Important Safety Instructions Read all warnings and instructions in this manual Save these instructions ti11959a Pump Air Control contains an RF devise with the following approvals FCC ID T...

Страница 2: ...plug or unplug power cords or turn lights on or off when flammable fumes are present Ground all equipment in the work area Use only grounded hoses If there is static sparking or you feel a shock stop...

Страница 3: ...mpletely remove cable 5 Loosen screw c on the back of the mini DIN sole noid connection and disconnect solenoid 6 Remove screw e from front cover f on mini DIN solenoid connection 7 Inside mini DIN so...

Страница 4: ...2 and green wire to GROUND 12 Replace cover f and screw e on mini DIN sole noid connection 13 Reconnect mini DIN solenoid connection to sole noid 14 Tighten screw c on back of mini DIN solenoid con n...

Страница 5: ...d MODE button e FIG 2 to select Matrix or Override mode In the MATRIX preferred g FIG 2 mode the pump will not operate unless it receives an authorization code from Matrix software Unau thorized dispe...

Страница 6: ...1 4 turn 3 Before you can resume normal PAC communication with Matrix you must reset the Manual Override Switch screw A to the normal operation position To to this insert small flat screwdriver in the...

Страница 7: ...urrent due to static build up or in the event of a short circuit Connect power cord to a 3 wire grounded plug according to your local electrical code The green ground wire must be attached to the gree...

Страница 8: ...4 No communication with internal RF module Replace circuit board Problem Cause Solution Flashing Seven Segment Display with NET ID and TRANS ID Unit is not registered with Matrix PC software Hold bot...

Страница 9: ...4 Leave the drain valve open until you are ready to pressurize the system Solenoid 2 Replacement For the following instructions refer to FIG 5 and parts pages 10 and 10 1 Unplug power cord from outlet...

Страница 10: ...Parts 10 312417F Parts 15 1 5 19 4 8 12 11 13 14 10 9 18 7 3 6 17 2 ti12325a Model 247436 Torque to 20 in lbs 2 N m 1 Torque to 25 in lbs 3 N m 2 Apply pipe sealant 3 3 2 1 5a...

Страница 11: ...EL identification 1 F N Part No Description Qty Operating Pressure Range 23 145 PSI 1 7 10 bar Maximum Air Flow 93 SCFM 2 6m3 min Air Supply to PAC 3 8 NPT Female Air Outlet to Pump 3 8 NPT Female Pow...

Страница 12: ...n of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRAN...

Отзывы: