Repair
26
3A3169E
11. Install reservoir (27) into the pump base (1) with
Graco Identification label (GL) facing to the front of
the pump base as shown in F
. 58. Take care to not
pinch or move the o-ring.
12. Apply a thin layer of grease to o-ring (26). Install
o-ring inside groove in cover (30) as shown in (F
NOTE:
This is the only correct way to install this
o-ring and ensure it will not slip out of place when
the cover is installed on the reservoir.
13. Position cover (30) over reservoir (27). Take care to
not pinch or move the o-ring (F
14. Install tie rods (29) Evenly tighten tie rods in a diag-
onal pattern, a little at a time. Torque to 12-13 in.
lbs. (1.4 - 1.5 N•m). Take care not to over tighten
any of the rods.
15. Reinstall the pump in the service location. See
Installation Instructions beginning on page 4.
F
IG
. 59
F
IG
. 60
30
26
30
27
26
F
IG
. 61
29
30