6.
Use an ohmmeter (or megohmmeter in the ohm
range) to measure the resistance between the
gun handle (BB) and a true earth ground (CC).
The resistance should not exceed 100 ohms.
7.
If the resistance is greater than 100 ohms, check
the tightness of the ground connections and be
sure the air hose ground wire is connected to a
true earth ground. If the resistance is still too
high, replace the air hose.
Figure 22 Check the Electrical Grounding of the
Gun
8.
Use an ohmmeter (or megohmmeter in the ohm
range) to measure the resistance between the
cabinet ground lug (214) and a true earth ground
(CC). The resistance must be less than 100
ohms.
Figure 23 Check the Grounding of the Cabinet
Flush
Flush
Flush the
the
the Equipment
Equipment
Equipment Before
Before
Before First
First
First Use
Use
Use
The equipment was tested in fluid at the factory. To
avoid contaminating your fluid, flush the equipment
with flushing fluid before you use the equipment. See
Flush the System (Systems without Color Change),
page 33
or
Flush the System (Color Change Enabled
.
28
3A7370C