Technical Data
Husky 2200 Diaphragm Pump
US
Metric
Maximum fluid working pressure
125 psi
0.86 MPa, 8.6 bar
Air pressure operating range
20 to 125 psi
0.14 to 0.86 MPa, 1.4 to 8.6 bar
Air inlet size
3/4 in. npt(f)
Air exhaust size
1 in. npt (f)
Fluid inlet and outlet size (ANSI/DIN
flange)
2 in
50 mm
Maximum suction lift (reduced
if balls don’t seat well due to
damaged balls or seats, lightweight
balls, or extreme speed of cycling)
Wet: 31 ft
Dry: 16 ft
Wet: 9.4 m
Dry: 4.9 m
Maximum size pumpable solids
1/4 in.
6.3 mm
Minimum ambient air temperature
for operation and storage.
NOTE: Exposure to extreme low
temperatures may result in damage
to plastic parts.
32° F
0° C
Air consumption
Standard diaphragms
70 scfm at 70 psi; 100 gpm
2.0 m
3
/min at 0.48 MPa, 4.8
bar, 379 lpm
Overmolded diaphragms
75 scfm at 70 psi, 100 gpm
2.1 m
3
/min at 0.48 MPa, 4.8
bar, 379 lpm
Maximum air consumption
Standard diaphragms
140 scfm
4.0 m
3
/min
Overmolded diaphragms
157 scfm
4.4 m
3
/min
Noise (dBa)
Sound power measured per ISO-9614–2. Sound pressure was tested 3.28 ft (1 m) from equipment.
95.2 at 70 psi and 50 cpm
95.2 at 4.8 bar and 50 cpm
Sound Power
101.8 at 100 psi and full flow
101.8 at 7.0 bar and full flow
87.3 at 70 psi and 50 cpm
87.3 at 4.8 bar and 50 cpm
Sound Pressure
94.7 at 100 psi and full flow
94.7 at 7.0 bar and full flow
Fluid flow per cycle
Standard diaphragms
1.6 gallons
6.1 liters
Overmolded diaphragms
1.3 gallons
4.9 liters
Maximum free-flow delivery
Standard diaphragms
200 gpm
757 lpm
Overmolded diaphragms
200 gpm
757 lpm