Operation
Operation
Operation
Pressure
Pressure
Pressure Relief
Relief
Relief Procedure
Procedure
Procedure
Follow the Pressure Relief Procedure
whenever you see this symbol.
000000
000000
000000
000000
000000
000000
This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the
Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing the
equipment.
1.
Turn off the fluid supply to the meter.
2.
Shut off all power to the fluid system.
3.
Follow the Pressure
Pressure
Pressure Relief
Relief
Relief Procedure
Procedure
Procedure for your
fluid system dispensing device.
Flow
Flow
Flow Meter
Meter
Meter Operation
Operation
Operation
To reduce the risk of component rupture, which
could cause injury from splashing fluid, do not
exceed the maximum working pressure of your
meter or any component or accessory in your
system.
For information on the G3000 Graco flow meter, see
manual 308778. For information on the Coriolis flow
meter, see manual 313599. Calibrate the meter as
instructed before using the meter for production.
NOTICE
NOTICE
NOTICE
The flow meter gears and bearings can be
damaged if they rotate at too high a speed. To
avoid high speed rotation, open the fluid valve
gradually. Do not over-speed the gear with air or
solvent. To prolong meter life, do not use the meter
above its maximum flow rate.