Error
Error
Error
Location
Location
Location
Type
Type
Type
Description
Description
Description
Cause
Cause
Cause
Solution
Solution
Solution
Disconnected or
loose RTD cable
or connection
Check all wiring and
connections to the RTD.
T6DA
Heater A
Sensor Error A
Bad RTD
Switch the RTD with
another and see if the
error message follows
the RTD. Replace RTD if
the error follows the RTD.
Disconnected or
loose RTD cable
or connection
Check all wiring and
connections to the RTD.
T6DB
Heater B
Sensor Error B
Bad RTD
Switch the RTD with
another and see if the
error message follows
the RTD. Replace RTD if
the error follows the RTD.
T6DH
Hose
Sensor Error Hose
Disconnected
or shorted RTD
cable in hose or
bad FTS
Expose each hose RTD
connection to check and
retighten any loose con-
nector. Measure hose
RTD cable and FTS conti-
nuity. See
. Order
RTD Test kit 24N365 for
measurement.
Disconnect the hose RTD
and use Hose Manual
Mode or Hose Resistance
Mode to continue the job
until repair can be com-
pleted. Hose Resistance
Mode requires a saved
calibration factor. Refer
to your proportioner op-
eration manual to enable
Hose Control Modes.