Error
Error
Error
Location
Location
Location
Type
Type
Type
Description
Description
Description
Cause
Cause
Cause
Solution
Solution
Solution
Resin inlet
pressure is too
low
Increase resin feed pump
pressure.
F9FB
ADM
Flow Cutback Low
Inlet B Pressure
Resin inlet flow is
too low
Change to larger resin
feed pump.
EVCH
ADM
Hose Manual Mode
Enabled
Hose Manual
Mode has been
enabled in
System Setup
screen
Install a functioning fluid
temperature sensor (FTS)
in the hose or run in Hose
Resistance Mode with a
properly saved calibra-
tion factor. Follow the
EAUX
ADM
USB Busy
USB drive has
been inserted to
the ADM
Do not remove USB drive
until download/upload is
complete.
EVSX
HCM
Standby
System has
entered standby
Trigger gun to resume
spraying.
Turn off standby in setup
screens.
EVUX
ADM
USB disabled
USB down-
load/uploads are
disabled
Enable USB down-
load/uploads on the
Advanced Setup screen
before inserting a USB
drive.
H2MA
Heater A
Low Frequency A
Line frequency is
below 45 Hz
Ensure line frequency
of incoming power is
between 45 and 65 Hz.
H2MB
Heater B
Low Frequency B
Line frequency is
below 45 Hz
Ensure line frequency
of incoming power is
between 45 and 65 Hz.
H2MH
Hose
Low Frequency
Hose
Line frequency is
below 45 Hz
Ensure line frequency
of incoming power is
between 45 and 65 Hz.
H3MA
Heater A
High Frequency A
Line frequency is
above 65 Hz
Ensure line frequency
of incoming power is
between 45 and 65 Hz.
H3MB
Heater B
High Frequency B
Line frequency is
above 65 Hz
Ensure line frequency
of incoming power is
between 45 and 65 Hz.
H3MH
Hose
High Frequency
Hose
Line frequency is
above 65 Hz
Ensure line frequency
of incoming power is
between 45 and 65 Hz.
L1AX
ADM
Low Chemical Level
A
Low material
level
Refill material and update
drum level on ADM
Maintenance screen.
Alarm can be disabled on
the System Setup screen.
334946J