Error
Error
Error
Location
Location
Location
Type
Type
Type
Description
Description
Description
Cause
Cause
Cause
Solution
Solution
Solution
Damaged ISO
pump
Inspect the ISO pump and
replace if necessary.
Fluid leak
between ISO
pump and meter
Inspect fluid lines for ISO
leaks.
Damaged ISO
recirculation
valve
Replace the ISO valve.
Damaged ISO
flow meter
Replace the ISO meter.
ISO material
drum is empty
Replace the ISO drum.
R1D0
ADM
Low Ratio Low Flow
A
Cavitation in the
ISO pump
Increase the ISO feed
pump pressure.
Damaged resin
pump
Inspect the resin pump
and replace if necessary.
Fluid leak
between resin
pump and meter
Inspect the fluid lines for
resin leak.
Damaged resin
recirculation
valve
Replace the resin valve.
Damaged resin
flow meter
Replace the resin meter.
Resin material
drum is empty
Replace the resin drum.
R4D0
ADM
High Ratio Low
Flow B
Cavitation on
resin pump
Increase the resin feed
pump pressure.
Damaged ISO
flow meter
Replace the ISO meter.
No ISO flow
Verify that the ISO inlet
valves are open.
R9AX
ADM
No Pulses A Flow
Meter
The ISO flow
meter is clogged
Clean the ISO flow meter.
Damaged resin
flow meter
Replace the resin meter.
No resin flow
Verify that the resin inlet
valves are open.
R9BX
ADM
No Pulses B Flow
Meter
Flow resin meter
is clogged
Clean the resin flow
meter.
28
334946J