Display
Display
Display
Code
Code
Code
Applicable
Applicable
Applicable
Motor
Motor
Motor
Blink
Blink
Blink
Code
Code
Code
Alarm
Alarm
Alarm or
or
or
Deviation
Deviation
Deviation
Description
Description
Description
EBC_
EBC_
EBC_
Advanced
None
Advisory
Run/Stop switch in Stop position (closed).
ELI_
ELI_
ELI_
Basic and
Advanced
4–5
Deviation Deviation hot board reset.
ERR0_
ERR0_
ERR0_
Basic and
Advanced
2–5
Deviation Deviation software error.
F1F0
F1F0
F1F0
None
Alarm
Fill pump flow not detected. The primary tank level has not
increased with the no flow timeout window and the no flow
timeout event is set to alarm.
F2F0
F2F0
F2F0
None
Deviation Fill pump flow not detected. The primary tank level has not
increased with the no flow timeout window and the no flow
timeout event is set to deviation.
K1D_
K1D_
K1D_
Advanced
1–2
Alarm
Flow is below minimum limit.
K2D_
K2D_
K2D_
Advanced
None
Deviation Flow is below minimum limit.
K3D_
K3D_
K3D_
Advanced
None
Deviation Flow exceeds maximum target; also indicates pump runaway
condition exists.
K4D_
K4D_
K4D_
Basic and
Advanced
1
Alarm
Flow exceeds maximum target; also indicates pump runaway
condition exists.
L1A0
L1A0
L1A0
None
Alarm
The flow rate is above the current profile flow limit set on Profile
Screen 3.
L1AF
L1AF
L1AF
Advanced
None
Alarm
While the system was in off production mode, the current tank
level dropped 3% below the value that was recorded when the
pump entered off production.
L2A0
L2A0
L2A0
Advanced
None
Deviation The primary tank current level is below the primary tank deviation
set point.
L3A0
L3A0
L3A0
Advanced
None
Deviation The primary tank current level is above the primary tank deviation
set point.
L4A0
L4A0
L4A0
None
Alarm
The primary tank level is above the primary tank level high alarm
set point.
L6CA
L6CA
L6CA
None
Deviation Port 8 is enabled and the current draw is less than 4 mA. The
BPR is requesting a value greater than 0%. Verify that the device
is connected.
L6CB
L6CB
L6CB
None
Deviation Port 9 is enabled and the current draw is less than 4 mA. Verify
that the device is connected.
MND_
MND_
MND_
Advanced
None
Advisory
Maintenance counter is enabled and countdown reached zero
(0).
P1CB
P1CB
P1CB
Advanced
None
Alarm
Pressure transducer 2 pressure is below the alarm set point.
P1D_
P1D_
P1D_
Advanced
None
Deviation Unbalanced load. Dual Lower system — P1D1 = Motor 1 is
requiring less force to hold speed; pump lower may need service.
P1D2 = Motor 2 is requiring less force than motor 1 to hold speed.
P9D_
P9D_
P9D_
Advanced
None
Deviation Major unbalanced load — see P1D_ (P9D_ is higher magnitude)
P1I_
P1I_
P1I_
Advanced
1–3
Alarm
Pressure is below minimum limit.
P2I_
P2I_
P2I_
Advanced
None
Deviation Pressure is below minimum limit.
P2CB
P2CB
P2CB
Advanced
None
Deviation Pressure transducer 2 pressure is below the deviation set point.
P3CB
P3CB
P3CB
Advanced
None
Deviation Pressure transducer 2 pressure is above the deviation set point.
P3I_
P3I_
P3I_
Advanced
None
Deviation Pressure exceeds maximum target.
P4CB
P4CB
P4CB
Advanced
None
Alarm
Pressure transducer 2 pressure is above the alarm set point.
P4I_
P4I_
P4I_
Advanced
1–4
Alarm
Pressure exceeds maximum target.
3A3453H