Setup
Setup
Setup Screen
Screen
Screen 13
13
13
Use this screen to configure and control the tank fill
feature and Intelligent Paint Kitchen peripherals.
NOTE:
NOTE:
NOTE: The alert trigger time varies based on how far
active measurements are from their set limits.
Figure 49 Setup Screen 13
Setup
Setup
Setup Screen
Screen
Screen 13
13
13 Key
Key
Key
Select this box to manually activate the
fill solenoid output on port 4, pin 3.
NOTE:
NOTE:
NOTE: The non-editable box shows the
status of the modbus register.
Select this box to enable the tank to
automatically fill. You can then set the
fill levels.
When the tank level reaches this
level, the fill solenoid turns off.
This value cannot be higher than
the level below.
When the tank level reaches this
level, the fill solenoid turns on.
This value cannot be lower than
the level above.
Configure the low fill pump flow
notification for a deviation or an alarm
and set the time-out value in seconds.
If a 1% level change is not detected
with the timeout period in seconds, the
system takes action based on the event
type.
3A3453H
39