Setup
Setup
Setup Screen
Screen
Screen 2
2
2
Use this screen to set the maximum, target, and
minimum fluid pressure for a selected profile. In
pressure mode, you will set a target fluid pressure.
In flow mode, you will set a maximum fluid pressure.
In either pressure or flow mode, a minimum pressure
may be set if desired. See
to specify how the system will respond if the pump
begins to operate outside of the set boundaries.
Figure 21 Setup Screen 2
Setup
Setup
Setup Screen
Screen
Screen 2
2
2 Key
Key
Key
Profile selection — See Step 2.
Select the profile (1 to 4) from the menu.
Fluid pressure maximum— See Step 3.
In flow mode, set the maximum pump
fluid force/pressure, as a percentage of
the maximum pressure of your pump.
This field is not used in pressure mode.
NOTE: If the profile does not have a
maximum pressure setting, the motor will
not run and error code WSCX appears.
Fluid pressure target — See Step 4.
In force/pressure mode, set the force/fluid
pressure target as a percentage of the
maximum pressure of your pump. This
field is not used in flow mode.
NOTE: If closed loop pressure is
enabled, the target pressure is displayed
as a pressure value (psi, bar, MPa)
rather than a percentage of maximum
pressure.
See
to enable
closed loop pressure control.
Fluid pressure minimum — See Step 5.
Optionally, set a minimum pump
force/fluid pressure, as a percentage of
the maximum force/fluid pressure of your
pump.
This softkey is disabled by default, and
only appears if the Profile
Profile
Profile Lock
Lock
Lock box is
checked on
.
Press to activate the profile just edited.
NOTE:
NOTE:
NOTE: If closed loop pressure is enabled, the
pressure will be displayed as a pressure value
rather than a percentage of maximum pressure.
See
to enable closed loop
pressure control.
1.
Select the desired profile (1 to 4), using the
pull-down menu.
2.
In flow
flow
flow mode
mode
mode, set the desired maximum pump
fluid pressure, as a percentage of the maximum
pressure of your pump.
NOTE:
NOTE:
NOTE: The motor will not run if the profile does
not have a maximum pressure setting. This field
is not used in pressure mode.
3.
In pressure
pressure
pressure mode
mode
mode, set the desired fluid pressure
target as a percentage of the maximum pressure
of your pump. This field is not used in flow mode.
4.
If desired, set a minimum pump fluid pressure,
as a percentage of the maximum fluid pressure
of your pump.
30