Electric Motor
3A2247A
19
3 Phase, 400 VAC, 50 Hz, Electric Motor
1.
Relieve pressure
, page 9. Unplug power cord.
2.
Remove
Fan Belt,
page 14.
3.
Loosen electric motor nut (205). Swing motor
retainer bracket (204) out.
4.
Remove motor assembly from sprayer.
5.
Remove motor junction box cover (J).
6.
Tilt motor junction box cover back and disconnect
three power leads (brown, black, and grey wires)
and the yellow and green ground wire (see
Wiring
Diagram
, page 29).
7.
Remove cable strain relief fitting (S) from motor
junction cover and pull motor power lead (3) and
motor ground wire from motor junction cover.
8.
Remove four screws (30), nuts (174) and handle
(175) from motor mounting bracket (99).
9.
Remove four screws (23), nuts (174), and electric
motor (119) from motor mounting bracket (99).
10. Loosen set screws (2) and remove pulley (43) from
electric motor.
204
205
43
30
119
175
30
190
192
191
193
ti18617a
200
198
ti5384a
ti18749a
ti18700a
S
J